N. Suweden
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
N. Suweden has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Made Suarda
Mechanical Engineering Department, Udayana University, Badung 80362, Indonesia
2 shared publications - Made Sucipta
Universitas Udayana
2 shared publications - Ni Made Suaniti
Program Studi Kimia FMIPA Universitas Udayana, Bukit Jimbaran, Bali
2 shared publications - I Putu Widiarta
Program Studi Magister Teknik Mesin, Fakultas Teknik Universitas Udayana
1 shared publication - I. Gusti Komang Dwijana
Mechanical Engineering Department of Udayana University, Street of Bukit Jimbaran, Bali 80361, Indonesia
1 shared publication I.G.K. Dwijana
Meter. Pompa hydram telah didesain dibuat
1 shared publication
Latest Publications
- Open Access
- 14 April 2023
- Published by Universitas Udayana in Buletin Udayana Mengabdi
- Vol. 23 (1) , 73-78
OPTIMASI MASSA KATUP LIMBAH POMPA HYDRAM TERPASANG DI WILAYAH MUNDUK GUNUNG DESA PETANG
This paper investigated the effect of the mass of the waste valve of hydraulic ram pump which has been designed and installed to deliver the clean water to the community house in the Munduk Gunung area, Petang Village. Public facilities are still minimal. One of them is the unavailability of clean water service facilities for the community, where people still rely on rainwater or buy water tanks. In accordance with the name of the area, this residential area is located in the highlands (512 m.swl), while the available water sources are in the lowlands (410 m.swl) with an elevation difference of 102 meters. The distance from the spring to the reservoir is 600 meters through a steep cliff. Initial survey results show that the spring has a flow capacity of about 3 liters/second and a potential head of 4.5 meters. The hydraulic ram pump has been designed, built, installed and operated with funding supported through the PNBP service grant from Udayana University, the PUMA scheme. The hydraulic ram pump performance test has been carried out on five variations of the waste valve mass. Performance testing shows that this hydraulic ram pump reaches its optimal performance at a mass of 3.25 kg of waste valve. Under these optimal conditions, this hydraulic ram pump operates at a total efficiency of 95% with a pumping flow of 0.115 lt/sec or 9.94 m3/day) at a pumping elevation of 102 meters, with an economic value of up to Rp. 17,885,000 per month. Therefore, it is with an investment cost of around Rp. 42,500,000 and requires almost no operational costs because it does not require fuel or electrical energy, consequently this hydram pump is very profitable to apply. Keywords: Hydraulic ram pump, waste valve mass, pump performance, Munduk Gunung area, Petang village.
- 14 April 2023
- Published by Universitas Udayana in Buletin Udayana Mengabdi
- Vol. 23 (1) , 73-78
Open AccessOPTIMASI MASSA KATUP LIMBAH POMPA HYDRAM TERPASANG DI WILAYAH MUNDUK GUNUNG DESA PETANG
This paper investigated the effect of the mass of the waste valve of hydraulic ram pump which has been designed and installed to deliver the clean water to the community house in the Munduk Gunung area, Petang Village. Public facilities are still minimal. One of them is the unavailability of clean water service facilities for the community, where people still rely on rainwater or buy water tanks. In accordance with the name of the area, this residential area is located in the highlands (512 m.swl), while the available water sources are in the lowlands (410 m.swl) with an elevation difference of 102 meters. The distance from the spring to the reservoir is 600 meters through a steep cliff. Initial survey results show that the spring has a flow capacity of about 3 liters/second and a potential head of 4.5 meters. The hydraulic ram pump has been designed, built, installed and operated with funding supported through the PNBP service grant from Udayana University, the PUMA scheme. The hydraulic ram pump performance test has been carried out on five variations of the waste valve mass. Performance testing shows that this hydraulic ram pump reaches its optimal performance at a mass of 3.25 kg of waste valve. Under these optimal conditions, this hydraulic ram pump operates at a total efficiency of 95% with a pumping flow of 0.115 lt/sec or 9.94 m3/day) at a pumping elevation of 102 meters, with an economic value of up to Rp. 17,885,000 per month. Therefore, it is with an investment cost of around Rp. 42,500,000 and requires almost no operational costs because it does not require fuel or electrical energy, consequently this hydram pump is very profitable to apply. Keywords: Hydraulic ram pump, waste valve mass, pump performance, Munduk Gunung area, Petang village.
- Open Access
- 6 April 2023
- Published by Universitas Udayana in Buletin Udayana Mengabdi
- Vol. 23 (1) , 29-34
UJI PERFORMANSI POMPA HYDRAM DALAM PENYEDIAAN AIR BERSIH KELOMPOK USAHA BON BELOK KOPI DAN BANJAR ADAT BON DESA BELOK/SIDAN
This paper examined the performance of the hydraulic ram pump that has been designed and installed to meet the clean water needs of the 'Bon Belok Kopi' Business Group and several families of Bon traditional community in Belok/Sidan Village, Petang District, Badung Regency, Bali Province. This business group is shortage to clean water in the process of processing their coffee production so that the community relies on rainwater and buys water from tank cars at a price of sixty thousand rupiah per cubic meter. Likewise, the Bon traditional community experienced the same problem, especially for their traditional activities. This problem has an impact on the capacity, quality and cost of coffee production of the business group, as well as the cleanliness, health and economy of the Bon traditional community. In the Bon area, there is a spring in the garden area belonging to the head of the business group with a flow rate of 3 liters/second at an elevation of 1024 m.swl, while residential areas are located at an elevation of 1135 m.swl. The hydraulic ram pump has been designed, built, installed and operated. The hydraulic ram pump performance test has been carried out on five variations of the pumping head. At a pumping head of 70 m, at the location of coffee processing, it produces a pumping flow of 8.84 m3/day with the pump efficiency of 71%. Meanwhile, at the highest pumping head of 110 m, at Puncak Bon Temple, it produces a pumping discharge of 5.04 m3/day with the pump efficiency of 59%. Keywords: Hydram pump, pump performance, Bon Belok Kopi, Bon traditional community.
- 6 April 2023
- Published by Universitas Udayana in Buletin Udayana Mengabdi
- Vol. 23 (1) , 29-34
Open AccessUJI PERFORMANSI POMPA HYDRAM DALAM PENYEDIAAN AIR BERSIH KELOMPOK USAHA BON BELOK KOPI DAN BANJAR ADAT BON DESA BELOK/SIDAN
This paper examined the performance of the hydraulic ram pump that has been designed and installed to meet the clean water needs of the 'Bon Belok Kopi' Business Group and several families of Bon traditional community in Belok/Sidan Village, Petang District, Badung Regency, Bali Province. This business group is shortage to clean water in the process of processing their coffee production so that the community relies on rainwater and buys water from tank cars at a price of sixty thousand rupiah per cubic meter. Likewise, the Bon traditional community experienced the same problem, especially for their traditional activities. This problem has an impact on the capacity, quality and cost of coffee production of the business group, as well as the cleanliness, health and economy of the Bon traditional community. In the Bon area, there is a spring in the garden area belonging to the head of the business group with a flow rate of 3 liters/second at an elevation of 1024 m.swl, while residential areas are located at an elevation of 1135 m.swl. The hydraulic ram pump has been designed, built, installed and operated. The hydraulic ram pump performance test has been carried out on five variations of the pumping head. At a pumping head of 70 m, at the location of coffee processing, it produces a pumping flow of 8.84 m3/day with the pump efficiency of 71%. Meanwhile, at the highest pumping head of 110 m, at Puncak Bon Temple, it produces a pumping discharge of 5.04 m3/day with the pump efficiency of 59%. Keywords: Hydram pump, pump performance, Bon Belok Kopi, Bon traditional community.