DSDehlela Shabir

Dehlela Shabir

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dehlela Shabir has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Vision-based markerless surgical tool tracking in open surgery: A scoping review

    by Hawa Hamza, Rouaa Naim, Dehlela Shabir, Khaled Shaban, Julien Abinahed, Zhigang Deng, Nikhil V. Navkar

  • Open Access

    Dynamic Augmented Reality Cues for Telementoring in Laparoscopic Surgery: Usability Study

    by Jhasketan Padhan, Hawa Hamza, Dehlela Shabir, Julien Abinahed, Panagiotis Tsiamyrtzis, Zhigang Deng, Nikhil V Navkar

    Background: Surgical telementoring enables a remote expert surgeon (mentor) to guide an operating surgeon (mentee) during surgery and facilitates the transfer of surgical skills. However, commonly used audio and static visual cues are inadequate to demonstrate complex tool-tissue interactions. To overcome this limitation, dynamic augmented reality (AR)–based visual cues are overlayed on the operative field to demonstrate precise instrument movements. Objective: The objective of this work was to evaluate dynamic AR cues and identify the most suitable cue that effectively demonstrates the required motions of surgical instruments during laparoscopy. Methods: A user study was conducted in a simulated environment among mentor-mentee pairs using 3 dynamic AR cues (hand gestures, a 3D pointer, and a virtual tool). The task assessed how closely the mentee was able to follow the mentor. The outcomes measured were (1) dynamic time warping distance, representing the closeness of the paths followed; (2) angular error in tooltip orientation; and (3) the NASA Task Load Index, assessing cognitive workload during telementoring. Results: Telementoring using the virtual tool resulted in a reduced dynamic time warping distance compared with hand gestures ( P <.01 for 12/13, 92.3% of the trials) and the 3D pointer ( P <.05 for 11/13, 84.6% of the trials). Lower orientation error was also noted while using the virtual tool as compared with hand gestures ( P <.05 for 5 of 6 poses). There were no substantial differences in the NASA Task Load Index scores. Conclusions: Use of a virtual tool (as a dynamic AR cue) enabled the mentee to follow the mentor’s instructions with fewer errors than both hand gestures and a 3D pointer without increasing cognitive workload. Further research is needed to assess the clinical effectiveness of the virtual tool during live surgery.

  • Open Access

    A Real-Time Markerless Approach for 3D Pose Estimation of Laparoscopic Instruments in Surgical Training Simulators

    by Dehlela Shabir, Jhasketan Padhan, Nihal Abdurahiman, Julien Abinahed, Zhigang Deng, Nikhil V. Navkar

    Box trainers are widely used for laparoscopic skills training due to their ease of setup and realistic tool-tissue interaction. Automating skill assessment on these systems can enhance training by reducing analysis time and eliminating subjective evaluations. Achieving this requires accurate real-time estimation of the instrument tooltip’s three-dimensional (3D) pose. However, existing methods either depend on additional sensing hardware, which introduces ergonomic challenges, or lack real-time capabilities. A modular architecture has been developed for estimation of an instrument’s tooltip pose from video frames acquired during laparoscopic training. Our method incorporates a GPU-based algorithm that takes input from a customized deep learning model (YOLOv7), detects the edges of the surgical instrument, and computes tooltip’s 3D pose. Additionally, an automated 3D-pose dataset generation technique is introduced to generate datasets for training the model. Our method was evaluated using a vision-based tracking experiment, achieving 3D positional errors of 0.72 mm, 0.88 mm, and 3.81 mm over the X, Y, and Z-axes, and an orientation error of 5.65° with an end-to-end latency of 144 ms and sustained real-time throughput of 11.4 frames per second (fps). The proposed method enables accurate estimation of laparoscopic instrument tooltip poses without the need for additional hardware or markers. This work represents a significant step toward automated skill assessment in laparoscopic training using box trainers.