Hong-Duong Pham
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hong-Duong Pham has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Hoang-Viet Nguyen
Faculty of Electrical and Electronics Engineering, Thuyloi University, Hanoi, Vietnam
4 shared publications - Pham Duc Dai
Thuyloi University
2 shared publications - Thu Hien Nguyen1 shared publication
Thuy Nguyen Vu
1 shared publication
Latest Publications
- Open Access
- 6 July 2026
- Published by Elsevier in SSRN Electronic Journal
Adaptive Voltage-Group Lyapunov-Constrained Predictive Current Control for PMSM Drives Fed by Three-Level NPC Inverters
Predictive current control (PCC) is attractive for PMSM drives fed by three-level neutral-pointclamped (3L–NPC) inverters, but conventional weighted PCC is sensitive to the weighting factor between current tracking and dc-link capacitor-voltage balancing, while sequential PCC still depends on the fixed number of candidates retained after the first selection layer. To overcome these limitations, this paper proposes an adaptive voltage-group Lyapunov- constrained PCC (AVG-LC-PCC). The proposed method first uses the deadbeat voltage reference to rank voltage-vector groups and adaptively expand the candidate set according to the operating condition. Then, the redundant switching states associated with the selected voltage groups are fully restored to preserve the neutral-point balancing capability of the 3L–NPC inverter. A Lyapunov feasibility condition is imposed on the restored candidate set, and the final switching state is selected by optimizing only the dc-link capacitorvoltage balancing objective within the feasible domain. Thus, current tracking is maintained through deadbeat-oriented candidate construction and Lyapunov feasibility, whereas dc-link balancing is achieved without a weighted current–voltage cost function. When the feasible domain is insufficient, a fallback rule selects the candidate with the most favorable Lyapunov trend. Comprehensive simulation results under different speeds and load conditions demonstrate that AVG-LC-PCC provides a balanced compromise among current-tracking accuracy, torque-ripple suppression, current quality, dc-link capacitor-voltage balancing, and computational complexity. Furthermore, internal indices, including the evaluated candidate size, the number of Lyapunov-feasible states, the fallback activation rate, and the selected Lyapunov increment, are analyzed to reveal the decision-making mechanism of the proposed controller.
- 6 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAdaptive Voltage-Group Lyapunov-Constrained Predictive Current Control for PMSM Drives Fed by Three-Level NPC Inverters
Predictive current control (PCC) is attractive for PMSM drives fed by three-level neutral-pointclamped (3L–NPC) inverters, but conventional weighted PCC is sensitive to the weighting factor between current tracking and dc-link capacitor-voltage balancing, while sequential PCC still depends on the fixed number of candidates retained after the first selection layer. To overcome these limitations, this paper proposes an adaptive voltage-group Lyapunov- constrained PCC (AVG-LC-PCC). The proposed method first uses the deadbeat voltage reference to rank voltage-vector groups and adaptively expand the candidate set according to the operating condition. Then, the redundant switching states associated with the selected voltage groups are fully restored to preserve the neutral-point balancing capability of the 3L–NPC inverter. A Lyapunov feasibility condition is imposed on the restored candidate set, and the final switching state is selected by optimizing only the dc-link capacitorvoltage balancing objective within the feasible domain. Thus, current tracking is maintained through deadbeat-oriented candidate construction and Lyapunov feasibility, whereas dc-link balancing is achieved without a weighted current–voltage cost function. When the feasible domain is insufficient, a fallback rule selects the candidate with the most favorable Lyapunov trend. Comprehensive simulation results under different speeds and load conditions demonstrate that AVG-LC-PCC provides a balanced compromise among current-tracking accuracy, torque-ripple suppression, current quality, dc-link capacitor-voltage balancing, and computational complexity. Furthermore, internal indices, including the evaluated candidate size, the number of Lyapunov-feasible states, the fallback activation rate, and the selected Lyapunov increment, are analyzed to reveal the decision-making mechanism of the proposed controller.
- Open Access
- 22 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 13126-13149
Weighting-Factor-Free Predictive Torque Control Structures for 3L-NPC Inverter-Fed Induction Motor Drives
This paper investigates weighting-factor-free predictive torque control (PTC) strategies for induction motor drives supplied by a three-level neutral-point-clamped (3L-NPC) inverter. Three predefined switching-table-based schemes—PTC-ST1, PTC-ST2, and PTC-ST3—are proposed to eliminate weighting-factor tuning and online optimization. The methods are comparatively evaluated in terms of RMS torque and flux ripples, DC-link capacitor voltage deviation, stator current THD, switching losses, and computational complexity measured by the normalized event count (NEC). Simulation studies carried out in the MATLAB/Simulink environment confirm that PTC-ST2 achieves superior capacitor voltage balancing at the expense of torque performance, whereas PTC-ST1 ensures robust and balanced behavior across operating conditions. Overall, PTC-ST3 provides the most favorable compromise between torque quality, current harmonics, and implementation efficiency, making it suitable for high-speed drives with strict real-time constraints.
- 22 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 13126-13149
Open AccessWeighting-Factor-Free Predictive Torque Control Structures for 3L-NPC Inverter-Fed Induction Motor Drives
This paper investigates weighting-factor-free predictive torque control (PTC) strategies for induction motor drives supplied by a three-level neutral-point-clamped (3L-NPC) inverter. Three predefined switching-table-based schemes—PTC-ST1, PTC-ST2, and PTC-ST3—are proposed to eliminate weighting-factor tuning and online optimization. The methods are comparatively evaluated in terms of RMS torque and flux ripples, DC-link capacitor voltage deviation, stator current THD, switching losses, and computational complexity measured by the normalized event count (NEC). Simulation studies carried out in the MATLAB/Simulink environment confirm that PTC-ST2 achieves superior capacitor voltage balancing at the expense of torque performance, whereas PTC-ST1 ensures robust and balanced behavior across operating conditions. Overall, PTC-ST3 provides the most favorable compromise between torque quality, current harmonics, and implementation efficiency, making it suitable for high-speed drives with strict real-time constraints.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 110331-110367
Hierarchical Sliding-Constrained Finite Control Set Predictive Control for Single-Phase Grid-Connected 3L-NPC Inverters
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 110331-110367
Open AccessHierarchical Sliding-Constrained Finite Control Set Predictive Control for Single-Phase Grid-Connected 3L-NPC Inverters
- 28 August 2025
- Published by Kaunas University of Technology (KTU) in Elektronika ir Elektrotechnika
- Vol. 31 (4) , 30-39
Predictive Current Control with Selection Vector Table Scheme for 3L-NPC Inverter
The predictive current control (PCC) strategy has been widely applied to three-level neutral-point-clamped (3L-NPC) inverters to regulate the load current and balance the capacitor voltage. However, evaluating all 27 switching states in each sampling period imposes a significant computational burden. At the same time, current quality is sensitive to selection of weighting factors when multiple control objectives are simultaneously considered. To overcome these limitations, this paper proposes two methods, namely predictive current control with vector selection Table I (PCCT1) and vector selection Table II (PCCT2), in which only a subset of pre-selected switching states is employed for prediction and optimisation, thereby eliminating the need for weighting factor tuning in the cost function. As a result, computational complexity is significantly reduced and system stability is enhanced. The proposed PCCT methods demonstrate superior performance compared to conventional PCC under various operating conditions, ensuring accurate current tracking and consistent capacitor voltage balancing.
- 28 August 2025
- Published by Kaunas University of Technology (KTU) in Elektronika ir Elektrotechnika
- Vol. 31 (4) , 30-39
Predictive Current Control with Selection Vector Table Scheme for 3L-NPC Inverter
The predictive current control (PCC) strategy has been widely applied to three-level neutral-point-clamped (3L-NPC) inverters to regulate the load current and balance the capacitor voltage. However, evaluating all 27 switching states in each sampling period imposes a significant computational burden. At the same time, current quality is sensitive to selection of weighting factors when multiple control objectives are simultaneously considered. To overcome these limitations, this paper proposes two methods, namely predictive current control with vector selection Table I (PCCT1) and vector selection Table II (PCCT2), in which only a subset of pre-selected switching states is employed for prediction and optimisation, thereby eliminating the need for weighting factor tuning in the cost function. As a result, computational complexity is significantly reduced and system stability is enhanced. The proposed PCCT methods demonstrate superior performance compared to conventional PCC under various operating conditions, ensuring accurate current tracking and consistent capacitor voltage balancing.