Qiying Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qiying Liu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Feixiang Tang
Innvoation School of Integrated Circuits, Hefei University of Technology, Hefei, China.
4 shared publications Sheng Liu
3 shared publications- Siyu He
Wuhan University
3 shared publications - Zhaoxu Zhou
Wuhan University
3 shared publications - Jize Jiang
Key Laboratory of Transients in Hydraulic Machinery, Ministry of Education, School of Power and Mechanical Engineering, Wuhan University, Wuhan 430072, China
2 shared publications - Qianyun Shu2 shared publications
Latest Publications
- 6 July 2026
- Published by Elsevier in Measurement
- Vol. 288
High-Sensitivity photothermal trace mass sensing in viscous fluids utilizing porous Cu–Ni functionally graded microcantilevers
- 6 July 2026
- Published by Elsevier in Measurement
- Vol. 288
High-Sensitivity photothermal trace mass sensing in viscous fluids utilizing porous Cu–Ni functionally graded microcantilevers
- 13 March 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (10) , 105924
Size-dependent vibration and frequency reversal mechanism in porous Ni-Al 2 O 3 microplates: a modified couple stress theory approach
This work presents a theoretical study on the size-dependent free vibration of porous nickel-alumina functionally graded (FGM) microplates. A refined continuum model is established by integrating the modified couple stress theory (MCST) with Kirchhoff plate theory. Unlike traditional models, this framework explicitly incorporates a power-law distribution of the material length scale parameter and corrects for the physical neutral surface shift. The vibration characteristics under four distinct porosity distribution patterns (Even, X, O, and V-types) are systematically evaluated. Significantly, a counter-intuitive ‘frequency reversal phenomenon’ is revealed in the Ni-Al 2 O 3 system. It is found that while the uniform (Even) porosity yields higher fundamental frequencies in ceramic-rich regimes, the optimal strategy shifts to uneven distributions (specifically O-type) in metal-rich regimes. This reversal mechanism is attributed to the competition between global mass reduction and local stiffness preservation, driven by the extreme density contrast of the nickel phase. These findings provide new physical insights into the mass-stiffness coupling effect in micro-scale composites, offering theoretical guidance for high-performance MEMS resonator design.
- 13 March 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (10) , 105924
Size-dependent vibration and frequency reversal mechanism in porous Ni-Al 2 O 3 microplates: a modified couple stress theory approach
This work presents a theoretical study on the size-dependent free vibration of porous nickel-alumina functionally graded (FGM) microplates. A refined continuum model is established by integrating the modified couple stress theory (MCST) with Kirchhoff plate theory. Unlike traditional models, this framework explicitly incorporates a power-law distribution of the material length scale parameter and corrects for the physical neutral surface shift. The vibration characteristics under four distinct porosity distribution patterns (Even, X, O, and V-types) are systematically evaluated. Significantly, a counter-intuitive ‘frequency reversal phenomenon’ is revealed in the Ni-Al 2 O 3 system. It is found that while the uniform (Even) porosity yields higher fundamental frequencies in ceramic-rich regimes, the optimal strategy shifts to uneven distributions (specifically O-type) in metal-rich regimes. This reversal mechanism is attributed to the competition between global mass reduction and local stiffness preservation, driven by the extreme density contrast of the nickel phase. These findings provide new physical insights into the mass-stiffness coupling effect in micro-scale composites, offering theoretical guidance for high-performance MEMS resonator design.
- Open Access
- 5 March 2026
- Published by Elsevier in SSRN Electronic Journal
High-sensitivity Photothermal Trace Mass Sensing in Viscous Fluids utilizing Porous Cu-Ni FGM Microcantilevers
Resonant MEMS sensors operating in harsh fluidic environments demand high sensitivity and structural robustness, which conventional silicon devices often fail to provide. This paper proposes the design and comprehensive multiphysics calibration of a highly sensitive, photothermally actuated MEMS sensor utilizing a porous Cu-Ni functionally graded material (FGM) microcantilever. Rather than traditional power sensing, this study pioneers its application in trace mass sensing, providing a rigorous mass-loading calibration curve ([[EQUATION]]). The device exhibits an exceptional trace mass sensitivity of 25.5 Hz/ng in air and maintains a highly linear responsivity of 8.5 Hz/ng even in heavily damped aqueous environments. Through rigorous topology optimization, a central (O-type) pore distribution is identified as the optimal configuration to capture target molecules near the physical neutral plane, successfully overcoming the traditional mass-stiffness penalty. Furthermore, fluid-structure interaction analyses confirm the sensor's operational integrity in highly viscous fluids (e.g., gasoline and water), retaining significantly higher Q-factors than conventional counterparts. By validating these device-level metrics using the Modified Couple Stress Theory (MCST) and Temperature-Dependent Material Properties (TDMP), the proposed Cu-Ni FGM sensor offers a robust, high-stability paradigm for next-generation in-situ mass detection in harsh environments.
- 5 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHigh-sensitivity Photothermal Trace Mass Sensing in Viscous Fluids utilizing Porous Cu-Ni FGM Microcantilevers
Resonant MEMS sensors operating in harsh fluidic environments demand high sensitivity and structural robustness, which conventional silicon devices often fail to provide. This paper proposes the design and comprehensive multiphysics calibration of a highly sensitive, photothermally actuated MEMS sensor utilizing a porous Cu-Ni functionally graded material (FGM) microcantilever. Rather than traditional power sensing, this study pioneers its application in trace mass sensing, providing a rigorous mass-loading calibration curve ([[EQUATION]]). The device exhibits an exceptional trace mass sensitivity of 25.5 Hz/ng in air and maintains a highly linear responsivity of 8.5 Hz/ng even in heavily damped aqueous environments. Through rigorous topology optimization, a central (O-type) pore distribution is identified as the optimal configuration to capture target molecules near the physical neutral plane, successfully overcoming the traditional mass-stiffness penalty. Furthermore, fluid-structure interaction analyses confirm the sensor's operational integrity in highly viscous fluids (e.g., gasoline and water), retaining significantly higher Q-factors than conventional counterparts. By validating these device-level metrics using the Modified Couple Stress Theory (MCST) and Temperature-Dependent Material Properties (TDMP), the proposed Cu-Ni FGM sensor offers a robust, high-stability paradigm for next-generation in-situ mass detection in harsh environments.
- Open Access
- 4 March 2026
- Published by Elsevier in SSRN Electronic Journal
Design and Topology Optimization of a Porous FGM Micro-Resonant Sensor for High-Sensitivity VOCs Gas Detection
High-performance resonant mass sensors are increasingly demanded for the trace detection of volatile organic compounds (VOCs) and hazardous gases in environmental monitoring. A critical challenge in current gas sensors is the inherent trade-off between increasing the specific surface area for gas molecule adsorption and maintaining the structural stiffness required for high-frequency resonance. This paper proposes a novel high-sensitivity micro-resonant gas sensor based on a porous functionally graded material (FGM) sandwich microplate. To accurately calibrate the sensor's dynamic response at the micro-scale, a refined mathematical model is established using the Modified Couple Stress Theory (MCST) with a position-dependent material length scale parameter. Furthermore, a multi-objective topology optimization framework based on the Non-dominated Sorting Genetic Algorithm II (NSGA-II) is developed. Rather than using pre-defined porous patterns, the algorithm autonomously aligns the mass-removal regions with the physical neutral surface of the microplate. By maximizing mass reduction in this low-stress region while preserving flexural rigidity, the optimized free-topology design achieves a 29.9% increase in the fundamental frequency compared to conventional O-type designs. This frequency boost directly translates to a significantly enhanced mass responsivity, providing a rigorous theoretical and design foundation for next-generation trace gas measurement devices.
- 4 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDesign and Topology Optimization of a Porous FGM Micro-Resonant Sensor for High-Sensitivity VOCs Gas Detection
High-performance resonant mass sensors are increasingly demanded for the trace detection of volatile organic compounds (VOCs) and hazardous gases in environmental monitoring. A critical challenge in current gas sensors is the inherent trade-off between increasing the specific surface area for gas molecule adsorption and maintaining the structural stiffness required for high-frequency resonance. This paper proposes a novel high-sensitivity micro-resonant gas sensor based on a porous functionally graded material (FGM) sandwich microplate. To accurately calibrate the sensor's dynamic response at the micro-scale, a refined mathematical model is established using the Modified Couple Stress Theory (MCST) with a position-dependent material length scale parameter. Furthermore, a multi-objective topology optimization framework based on the Non-dominated Sorting Genetic Algorithm II (NSGA-II) is developed. Rather than using pre-defined porous patterns, the algorithm autonomously aligns the mass-removal regions with the physical neutral surface of the microplate. By maximizing mass reduction in this low-stress region while preserving flexural rigidity, the optimized free-topology design achieves a 29.9% increase in the fundamental frequency compared to conventional O-type designs. This frequency boost directly translates to a significantly enhanced mass responsivity, providing a rigorous theoretical and design foundation for next-generation trace gas measurement devices.
- 28 December 2025
- Published by Elsevier in Measurement
- Vol. 264
A microcantilever biosensor based on functionally graded materials: achieving highly sensitive detection of cell mass in various fluid environments
- 28 December 2025
- Published by Elsevier in Measurement
- Vol. 264
A microcantilever biosensor based on functionally graded materials: achieving highly sensitive detection of cell mass in various fluid environments