Jip H. van Daelen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jip H. van Daelen has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Elisabeth Janneke Huisman
Department of Pediatric Hematology and Oncology Erasmus MC Sophia Children's Hospital, University Medical Center Rotterdam Rotterdam The Netherlands
4 shared publications Pauline M. Snijder
Division of Neonatology, Department of Pediatrics Erasmus University Medical Center, Erasmus MC ‐Sophia Children's Hospital Rotterdam The Netherlands
4 shared publications- Enrico Lopriore
Division of Neonatology, Department of Pediatrics, Willem‐Alexander Children's Hospital Leiden University Medical Center Leiden the Netherlands
3 shared publications Irwin K. M. Reiss
Division of Neonatology, Department of Pediatrics Erasmus MC Sophia Children's Hospital, Erasmus Medical University Center Rotterdam the Netherlands
2 shared publications- Thomas Robert Leon Klei
Department of Product and Process Development Sanquin Blood Supply Amsterdam The Netherlands
2 shared publications - Alex J. Eggink
Division of Obstetrics and Fetal Medicine, Department of Obstetrics and Gynecology Erasmus University Medical Center, Erasmus MC ‐Sophia Children's Hospital Rotterdam The Netherlands
1 shared publication
Latest Publications
- Open Access
- 27 October 2026
- Published by Wiley in Transfusion
Development of a systematic drug screening method for cord blood donation for transfusion to extremely preterm neonates
Background: Cord blood‐derived red blood cell transfusions (CB‐RBCs) are being developed for extremely preterm neonates to preserve physiological fetal hemoglobin levels. We assessed how standard blood donor medication screening could be adapted for this novel donor population. Study Design and Methods: In the Drug‐Cord study, conducted in the Netherlands in 2025, we developed a structured, stepwise drug screening method for CB donation. The standard donor drug list was supplemented with drugs commonly prescribed during pregnancy and childbirth identified by clinical experts, after which two pharmacists assessed selected drugs based on maternal systemic absorption, placental transfer, and potential risks to the extremely preterm recipient. Results: The standard donor questionnaire included 988 drugs. After adding 21 drugs commonly prescribed during pregnancy, 1009 drugs were identified. Following exclusion of rarely used drugs ( n = 399), 610 were appraised. Of these, 179 (29.3%) were contraindicated by Sanquin (1A), 230 were contraindicated due to neonatal toxicity (1B; n = 131, 21.5%) or insufficient safety data (1C; n = 99, 16.2%), leaving n = 201 (33%) drugs approved (2A–2D). Discussion: A large proportion of drugs currently accepted for blood donation are unsuitable or cannot be reliably assessed for CB‐RBC transfusion in extremely preterm neonates. These findings highlight critical knowledge gaps in neonatal pharmacology, underscoring the need for a CB‐specific, precautionary, and dynamically updated CB‐donor drug screening questionnaire.
- 27 October 2026
- Published by Wiley in Transfusion
Open AccessDevelopment of a systematic drug screening method for cord blood donation for transfusion to extremely preterm neonates
Background: Cord blood‐derived red blood cell transfusions (CB‐RBCs) are being developed for extremely preterm neonates to preserve physiological fetal hemoglobin levels. We assessed how standard blood donor medication screening could be adapted for this novel donor population. Study Design and Methods: In the Drug‐Cord study, conducted in the Netherlands in 2025, we developed a structured, stepwise drug screening method for CB donation. The standard donor drug list was supplemented with drugs commonly prescribed during pregnancy and childbirth identified by clinical experts, after which two pharmacists assessed selected drugs based on maternal systemic absorption, placental transfer, and potential risks to the extremely preterm recipient. Results: The standard donor questionnaire included 988 drugs. After adding 21 drugs commonly prescribed during pregnancy, 1009 drugs were identified. Following exclusion of rarely used drugs ( n = 399), 610 were appraised. Of these, 179 (29.3%) were contraindicated by Sanquin (1A), 230 were contraindicated due to neonatal toxicity (1B; n = 131, 21.5%) or insufficient safety data (1C; n = 99, 16.2%), leaving n = 201 (33%) drugs approved (2A–2D). Discussion: A large proportion of drugs currently accepted for blood donation are unsuitable or cannot be reliably assessed for CB‐RBC transfusion in extremely preterm neonates. These findings highlight critical knowledge gaps in neonatal pharmacology, underscoring the need for a CB‐specific, precautionary, and dynamically updated CB‐donor drug screening questionnaire.
- Open Access
- 20 July 2026
- Published by Wiley in Vox Sanguinis
- Vol. 121 (11) , 1645-1652
Comparing the volume of umbilical cord blood collection using different techniques
Background and Objectives: Umbilical cord blood (UCB) as a source for red blood cell (RBC) transfusions is a promising alternative to adult RBC transfusions in extremely preterm neonates, as UCB contains predominantly fetal haemoglobin (HbF). A limitation to clinical use is the low and variable yield of UCB collections. This study aimed to assess UCB collection volume and feasibility across three techniques in uncomplicated term pregnancies. Materials and Methods: We conducted a prospective observational study in two centres in The Netherlands. We compared the volume of UCB units collected from uncomplicated term deliveries using three different techniques: in utero, ex utero with a funnel and ex utero with a plateau. A minimum target volume of 70 mL was deemed adequate for further processing. Results: Of 606 collection attempts, 570 (94%) were successful. The median UCB volume was 65 mL (interquartile range, IQR 49–84), with 242 (42.5%) collections ≥70 mL. Volumes differed significantly between the three techniques, with the ex utero plateau technique yielding the highest median volume (70 mL, IQR 55–88), followed by in utero (56 mL, IQR 45–71) and the funnel technique (36 mL, IQR 30–51) ( p < 0.001). UCB volume correlated with birth weight ( p < 0.001), but not with gestational age or sex. Volumes obtained with the plateau technique increased over time, suggesting a learning‐curve effect. Conclusion: Collected UCB volume was highest using the ex utero plateau technique and was associated with birth weight and operator experience. The observed learning curve underscores the importance of dedicated teams to maximize UCB collection efficiency for future transfusion use.
- 20 July 2026
- Published by Wiley in Vox Sanguinis
- Vol. 121 (11) , 1645-1652
Open AccessComparing the volume of umbilical cord blood collection using different techniques
Background and Objectives: Umbilical cord blood (UCB) as a source for red blood cell (RBC) transfusions is a promising alternative to adult RBC transfusions in extremely preterm neonates, as UCB contains predominantly fetal haemoglobin (HbF). A limitation to clinical use is the low and variable yield of UCB collections. This study aimed to assess UCB collection volume and feasibility across three techniques in uncomplicated term pregnancies. Materials and Methods: We conducted a prospective observational study in two centres in The Netherlands. We compared the volume of UCB units collected from uncomplicated term deliveries using three different techniques: in utero, ex utero with a funnel and ex utero with a plateau. A minimum target volume of 70 mL was deemed adequate for further processing. Results: Of 606 collection attempts, 570 (94%) were successful. The median UCB volume was 65 mL (interquartile range, IQR 49–84), with 242 (42.5%) collections ≥70 mL. Volumes differed significantly between the three techniques, with the ex utero plateau technique yielding the highest median volume (70 mL, IQR 55–88), followed by in utero (56 mL, IQR 45–71) and the funnel technique (36 mL, IQR 30–51) ( p < 0.001). UCB volume correlated with birth weight ( p < 0.001), but not with gestational age or sex. Volumes obtained with the plateau technique increased over time, suggesting a learning‐curve effect. Conclusion: Collected UCB volume was highest using the ex utero plateau technique and was associated with birth weight and operator experience. The observed learning curve underscores the importance of dedicated teams to maximize UCB collection efficiency for future transfusion use.
- Open Access
- 22 December 2025
- Published by Wiley in Transfusion
- Vol. 66 (7) , 1336-1346
Development and production of allogeneic cord blood‐derived red blood cell concentrates for transfusion to extremely preterm neonates, the All‐Cord study
Background: Extremely preterm neonates often require red blood cell (RBC) transfusions derived from adult donors. These transfusions introduce adult hemoglobin into a neonatal hematopoietic system dominated by fetal hemoglobin (HbF), shifting the oxygen‐dissociation curve and increasing oxygen delivery to immature tissues. This contributes to oxidative stress and has been associated with prematurity‐related diseases. Cord blood (CB)‐derived red cell concentrates (CB‐RCCs) offer a new physiological alternative by preserving HbF. To enable clinical implementation, CB‐RCCs must meet (inter)national quality standards. This study investigated the impact of pre‐filtration dilution, storage in non‐di(2‐ethylhexyl)phthalate (DEHP) plasticized bags, and three additive solutions—saline‐adenine‐glucose‐mannitol (SAGM), phosphate‐adenine‐glucose‐guanosine‐saline‐mannitol (PAGGSM), and SOL‐X—on CB‐RCC quality over 21 days. Study Design and Methods: CB was collected after term delivery and processed within 24 h into leukocyte‐ and platelet‐depleted CB‐RCCs. Products, either pre‐filtration diluted or undiluted, were stored up to 21 days in 1,2‐cyclohexane dicarboxylic acid diisononyl ester‐ or DEHP‐plasticized polyvinyl chloride bags containing SAGM, PAGGSM, or SOL‐X additive solutions. Quality parameters were assessed on Days 1, 7, 14, and 21. Quality standards were compared against (inter)national requirements for adult RCC. Results: Pre‐filtration dilution to maximize yield was found to impair product quality. CB‐RCCs stored in non‐DEHP bags with PAGGSM showed the lowest hemolysis at Day 21 (0.30 ± 0.09%), outperforming SAGM (0.57 ± 0.16%). Red blood cells in non‐DEHP bags also preserved adenosine triphosphate levels and deformability better than in DEHP bags. Discussion: We demonstrated that CB‐RCCs stored in non‐DEHP bags with PAGGSM as an additive solution meet (inter)national Blood Bank quality standards up to 21 days of in vitro storage.
- 22 December 2025
- Published by Wiley in Transfusion
- Vol. 66 (7) , 1336-1346
Open AccessDevelopment and production of allogeneic cord blood‐derived red blood cell concentrates for transfusion to extremely preterm neonates, the All‐Cord study
Background: Extremely preterm neonates often require red blood cell (RBC) transfusions derived from adult donors. These transfusions introduce adult hemoglobin into a neonatal hematopoietic system dominated by fetal hemoglobin (HbF), shifting the oxygen‐dissociation curve and increasing oxygen delivery to immature tissues. This contributes to oxidative stress and has been associated with prematurity‐related diseases. Cord blood (CB)‐derived red cell concentrates (CB‐RCCs) offer a new physiological alternative by preserving HbF. To enable clinical implementation, CB‐RCCs must meet (inter)national quality standards. This study investigated the impact of pre‐filtration dilution, storage in non‐di(2‐ethylhexyl)phthalate (DEHP) plasticized bags, and three additive solutions—saline‐adenine‐glucose‐mannitol (SAGM), phosphate‐adenine‐glucose‐guanosine‐saline‐mannitol (PAGGSM), and SOL‐X—on CB‐RCC quality over 21 days. Study Design and Methods: CB was collected after term delivery and processed within 24 h into leukocyte‐ and platelet‐depleted CB‐RCCs. Products, either pre‐filtration diluted or undiluted, were stored up to 21 days in 1,2‐cyclohexane dicarboxylic acid diisononyl ester‐ or DEHP‐plasticized polyvinyl chloride bags containing SAGM, PAGGSM, or SOL‐X additive solutions. Quality parameters were assessed on Days 1, 7, 14, and 21. Quality standards were compared against (inter)national requirements for adult RCC. Results: Pre‐filtration dilution to maximize yield was found to impair product quality. CB‐RCCs stored in non‐DEHP bags with PAGGSM showed the lowest hemolysis at Day 21 (0.30 ± 0.09%), outperforming SAGM (0.57 ± 0.16%). Red blood cells in non‐DEHP bags also preserved adenosine triphosphate levels and deformability better than in DEHP bags. Discussion: We demonstrated that CB‐RCCs stored in non‐DEHP bags with PAGGSM as an additive solution meet (inter)national Blood Bank quality standards up to 21 days of in vitro storage.