Hanyu Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hanyu Zhang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Xiaohua Che
Institute of Marine Optoelectronic Equipment, Harbin Institute of Technology, Weihai 264209, China
1 shared publication - Ying Guo
Institute of Marine Optoelectronic Equipment, Harbin Institute of Technology, Weihai 264209, China
1 shared publication - Zhaoshuo Tian
Institute of Marine Optoelectronic Equipment, Harbin Institute of Technology, Weihai 264209, China
1 shared publication - Zongjie Bi
Institute of Marine Optoelectronic Equipment, Harbin Institute of Technology at Weihai, Weihai 264209, China
1 shared publication
Latest Publications
- Open Access
Detection of Water Quality COD Based on the Integration of Laser Absorption and Fluorescence Spectroscopy Technology
Chemical oxygen demand (COD) serves as a critical indicator for assessing the extent of water pollution caused by organic matter. This study proposes an integrated COD detection methodology that combines laser absorption spectroscopy with laser-induced fluorescence spectroscopy, enabling accurate measurement of COD parameters across a wide concentration range. For high-concentration COD, conventional ultraviolet absorption spectrophotometry based on the Lambert–Beer law is employed. However, since laser absorption spectrophotometry exhibits substantial errors in detecting low-concentration COD, laser-induced fluorescence spectroscopy is adopted for the precise quantification of trace-level COD. By integrating these two laser-based approaches, a spectroscopic COD detection system has been developed that simultaneously records absorbance after the laser passes through the sample and quantifies fluorescence intensity perpendicular to the beam with an image sensor, thereby achieving comprehensive COD analysis. Laboratory validation using COD standard solutions demonstrated relative errors below 11% across the concentration range of 2–220 mg/L. Further application to natural water samples confirmed that the integrated laser absorption–fluorescence spectroscopy approach achieves wide-range COD measurement with high sensitivity, a compact configuration, and rapid response, demonstrating strong potential for real-time online water quality monitoring.
Open AccessDetection of Water Quality COD Based on the Integration of Laser Absorption and Fluorescence Spectroscopy Technology
Chemical oxygen demand (COD) serves as a critical indicator for assessing the extent of water pollution caused by organic matter. This study proposes an integrated COD detection methodology that combines laser absorption spectroscopy with laser-induced fluorescence spectroscopy, enabling accurate measurement of COD parameters across a wide concentration range. For high-concentration COD, conventional ultraviolet absorption spectrophotometry based on the Lambert–Beer law is employed. However, since laser absorption spectrophotometry exhibits substantial errors in detecting low-concentration COD, laser-induced fluorescence spectroscopy is adopted for the precise quantification of trace-level COD. By integrating these two laser-based approaches, a spectroscopic COD detection system has been developed that simultaneously records absorbance after the laser passes through the sample and quantifies fluorescence intensity perpendicular to the beam with an image sensor, thereby achieving comprehensive COD analysis. Laboratory validation using COD standard solutions demonstrated relative errors below 11% across the concentration range of 2–220 mg/L. Further application to natural water samples confirmed that the integrated laser absorption–fluorescence spectroscopy approach achieves wide-range COD measurement with high sensitivity, a compact configuration, and rapid response, demonstrating strong potential for real-time online water quality monitoring.