Peng Tao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Peng Tao has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Nan Wei
State Grid Economic and Technological Research Institute CO., LTD., Beijing 102209, China
1 shared publication - Qichao Chen
State Grid Economic and Technological Research Institute CO., LTD., Beijing 102209, China
1 shared publication - Renming Wang
College of Electrical Engineering and New Energy, China Three Gorges University, Yichang 443000, China
1 shared publication - Yiqi Liu
College of Computer and Control Engineering, Northeast Forestry University, Harbin 150040, China
1 shared publication - Zhi An
State Grid Economic and Technological Research Institute CO., LTD., Beijing 102209, China
1 shared publication - Zhidong Wang
State Grid Economic and Technological Research Institute CO., LTD., Beijing 102209, China
1 shared publication
Latest Publications
- Open Access
Improved LADRC Damping of Sub-Synchronous Oscillation in DFIG-Based Wind Power Systems Under Multiple Operating Conditions
An active damping control technique based on improved linear active disturbance rejection control (LADRC) is suggested to address the inadequate damping of doubly fed induction generator (DFIG) systems coupled to the grid using series compensation capacitors. Conventional LADRC still has certain limitations under complicated operating conditions, primarily because of its inadequate periodic disturbance estimate capabilities, which limit the system’s dynamic performance and disturbance-rejection capability. An enhanced LADRC scheme is created for the inner current loop of the rotor-side converter (RSC) in the DFIG system in order to lessen these restrictions. To enable a real-time estimate and adjustment of sub-synchronous disturbances, a decoupled linear extended state observer (LESO) is first proposed. In order to effectively attenuate both sub-synchronous oscillation and periodic disturbances, a composite control structure with enhanced suppression capability is constructed by incorporating an improved repetitive control scheme into the linear state error feedback law. The results show that the improved LADRC significantly enhances damping performance and disturbance rejection capability in the subsynchronous frequency range, suppressing active power oscillations within approximately 0.3 s based on a ±10% settling band. Compared with the conventional LADRC, the average THD of the grid current is reduced from 3.43% to 0.56%.
Open AccessImproved LADRC Damping of Sub-Synchronous Oscillation in DFIG-Based Wind Power Systems Under Multiple Operating Conditions
An active damping control technique based on improved linear active disturbance rejection control (LADRC) is suggested to address the inadequate damping of doubly fed induction generator (DFIG) systems coupled to the grid using series compensation capacitors. Conventional LADRC still has certain limitations under complicated operating conditions, primarily because of its inadequate periodic disturbance estimate capabilities, which limit the system’s dynamic performance and disturbance-rejection capability. An enhanced LADRC scheme is created for the inner current loop of the rotor-side converter (RSC) in the DFIG system in order to lessen these restrictions. To enable a real-time estimate and adjustment of sub-synchronous disturbances, a decoupled linear extended state observer (LESO) is first proposed. In order to effectively attenuate both sub-synchronous oscillation and periodic disturbances, a composite control structure with enhanced suppression capability is constructed by incorporating an improved repetitive control scheme into the linear state error feedback law. The results show that the improved LADRC significantly enhances damping performance and disturbance rejection capability in the subsynchronous frequency range, suppressing active power oscillations within approximately 0.3 s based on a ±10% settling band. Compared with the conventional LADRC, the average THD of the grid current is reduced from 3.43% to 0.56%.
- Open Access
A Supplementary Damping Control of D-STATCOM for Alleviating SSO in Photovoltaic Generation Integrated into Weak AC Grid
The interaction between the Photovoltaic station and the weak grid can easily trigger sub- or super-synchronous oscillation (SSO). In this article, the equivalent impedance model of the photovoltaic grid-connected system is built, and the mechanism of SSO is analyzed based on the global admittance criterion (GA). To mitigate the SSO, a Distribution Static Synchronous Compensator (D-STATCOM) supplementary damping control (SDC) strategy is proposed, which uses a three-parameter notch filter to extract the sub- or super-synchronous harmonic component without a phase shift. The component is superimposed on the modulated wave of the D-STATCOM through the gain link to obtain the modulation instruction. At the sub- or super-synchronous frequency, the D-STATCOM can be equivalent to the parallel impedance in the system and play a role in suppressing the sub- or super-synchronous oscillation. Compared to the complex combination filters in the traditional SDC, which require phase compensation and have poor adaptability, the three-parameter notch filter used in this SDC does not need a phase compensation stage and can effectively cope with the presence of oscillation frequencies on both sides of the fundamental frequency with a simpler design. Simulation results prove that the proposed scheme effectively improves the stability of photovoltaic generation under different short-circuit ratios, irradiance levels, and fault conditions. The proposed solution can be applied to photovoltaic generation equipped with D-STATCOM.
Open AccessA Supplementary Damping Control of D-STATCOM for Alleviating SSO in Photovoltaic Generation Integrated into Weak AC Grid
The interaction between the Photovoltaic station and the weak grid can easily trigger sub- or super-synchronous oscillation (SSO). In this article, the equivalent impedance model of the photovoltaic grid-connected system is built, and the mechanism of SSO is analyzed based on the global admittance criterion (GA). To mitigate the SSO, a Distribution Static Synchronous Compensator (D-STATCOM) supplementary damping control (SDC) strategy is proposed, which uses a three-parameter notch filter to extract the sub- or super-synchronous harmonic component without a phase shift. The component is superimposed on the modulated wave of the D-STATCOM through the gain link to obtain the modulation instruction. At the sub- or super-synchronous frequency, the D-STATCOM can be equivalent to the parallel impedance in the system and play a role in suppressing the sub- or super-synchronous oscillation. Compared to the complex combination filters in the traditional SDC, which require phase compensation and have poor adaptability, the three-parameter notch filter used in this SDC does not need a phase compensation stage and can effectively cope with the presence of oscillation frequencies on both sides of the fundamental frequency with a simpler design. Simulation results prove that the proposed scheme effectively improves the stability of photovoltaic generation under different short-circuit ratios, irradiance levels, and fault conditions. The proposed solution can be applied to photovoltaic generation equipped with D-STATCOM.