Renhao Chang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Renhao Chang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Ming Huang
School of Automation, Northwestern Polytechnical University, Xi’an 710072, China
4 shared publications - Weilin Li
Northwestern Polytechnical University
3 shared publications - Jianlong Zou
School of Electrical Engineering, Xian Jiaotong University, Xian, China
2 shared publications - Xikui Ma
State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xian Jiaotong University, Xian, China
2 shared publications - Yang Qi
Northwestern Polytechnical University
2 shared publications - Jiaan Yi
China Nucl. Power Technol. Res. Inst., Shenzhen, China
1 shared publication
Latest Publications
- 17 June 2026
- Published by Springer Nature
- p. 739-749
Dynamic Power Smoothing Technology for Hybrid Energy Storage in More Electric Aircraft Power Supply System
- 17 June 2026
- Published by Springer Nature
- p. 739-749
Dynamic Power Smoothing Technology for Hybrid Energy Storage in More Electric Aircraft Power Supply System
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (5) , 7724-7735
Novel Feedforward Control Enhanced by Dynamic Load-Current/Derivative Weights of Hybrid Energy Storage System for Pulsed Loads
To address the inadequate dynamic response characteristics of hybrid energy storage systems (HESS) in aviation dc microgrids under pulsed power loads caused by traditional PI control, this article proposes an optimized feedforward compensation strategy based on dynamic allocation of load-current and derivative weighting. This method bypasses the transient response limitations inherent in conventional PI control and incorporates a dynamic compensation term linked to the load current derivative directly into the duty cycle unit, enhancing the traditional dual-loop control framework. By perceiving real-time load current variations, the approach proactively adjusts power allocation coefficients among energy storage units. Compared with traditional PI control, it significantly reduces dc bus voltage recovery time under pulse load conditions, effectively enhancing bus voltage robustness and power quality. Furthermore, the article provides a theoretical analysis of the dynamic performance and stability of the proposed method from a system transfer function perspective. Finally, numerical simulations and experimental results validate the efficacy of the improved approach. The findings offer a theoretical foundation and technical reference for optimized power allocation design of HESS in high-reliability aviation dc microgrids.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (5) , 7724-7735
Novel Feedforward Control Enhanced by Dynamic Load-Current/Derivative Weights of Hybrid Energy Storage System for Pulsed Loads
To address the inadequate dynamic response characteristics of hybrid energy storage systems (HESS) in aviation dc microgrids under pulsed power loads caused by traditional PI control, this article proposes an optimized feedforward compensation strategy based on dynamic allocation of load-current and derivative weighting. This method bypasses the transient response limitations inherent in conventional PI control and incorporates a dynamic compensation term linked to the load current derivative directly into the duty cycle unit, enhancing the traditional dual-loop control framework. By perceiving real-time load current variations, the approach proactively adjusts power allocation coefficients among energy storage units. Compared with traditional PI control, it significantly reduces dc bus voltage recovery time under pulse load conditions, effectively enhancing bus voltage robustness and power quality. Furthermore, the article provides a theoretical analysis of the dynamic performance and stability of the proposed method from a system transfer function perspective. Finally, numerical simulations and experimental results validate the efficacy of the improved approach. The findings offer a theoretical foundation and technical reference for optimized power allocation design of HESS in high-reliability aviation dc microgrids.
- 31 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (5) , 7108-7120
Variable-Carrier-Based PWM Control of Hybrid Energy Storage System for More Electric Aircraft
The hybrid energy storage systems (HESSs), often configured with battery and supercapacitor (SC) combinations, can effectively regulate power imbalances between generation and loads within more electric aircraft (MEA) dc microgrids. However, traditional control exhibits limitation in precisely tracking high-frequency components within SC current loop. To address this deficiency, this article proposes a novel current control strategy enhancing SC current tracking capability in HESS. Departing from conventional approaches, the proposed strategy eliminates the proportional-integral (PI) controller from the SC current loop, instead integrating SC current regulation with pulse-width modulation (PWM) to form a modified PWM unit. Consequently, the input signal of this modified PWM unit derives from given function of the SC current, while the amplitude of the PWM carrier signal is reformulated to vary instantaneously with the SC current. The variable-carrier-based PWM method accelerates the realization of SC current synthesis. Furthermore, a small-signal model is also explored to deeply investigate the stability of the HESS. Subsequent simulations are conducted to verify the performance across multiple scenarios. Experimental validation conducted on a 25 kW HESS power stage demonstrates the theoretical feasibility of the proposed control methodology.
- 31 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (5) , 7108-7120
Variable-Carrier-Based PWM Control of Hybrid Energy Storage System for More Electric Aircraft
The hybrid energy storage systems (HESSs), often configured with battery and supercapacitor (SC) combinations, can effectively regulate power imbalances between generation and loads within more electric aircraft (MEA) dc microgrids. However, traditional control exhibits limitation in precisely tracking high-frequency components within SC current loop. To address this deficiency, this article proposes a novel current control strategy enhancing SC current tracking capability in HESS. Departing from conventional approaches, the proposed strategy eliminates the proportional-integral (PI) controller from the SC current loop, instead integrating SC current regulation with pulse-width modulation (PWM) to form a modified PWM unit. Consequently, the input signal of this modified PWM unit derives from given function of the SC current, while the amplitude of the PWM carrier signal is reformulated to vary instantaneously with the SC current. The variable-carrier-based PWM method accelerates the realization of SC current synthesis. Furthermore, a small-signal model is also explored to deeply investigate the stability of the HESS. Subsequent simulations are conducted to verify the performance across multiple scenarios. Experimental validation conducted on a 25 kW HESS power stage demonstrates the theoretical feasibility of the proposed control methodology.
- 25 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Aerospace and Electronic Systems
- Vol. 62 (00189251) , 2321-2335
Enhanced Power Allocation Strategy of Hybrid Energy Storage System for MEA
The aviation hybrid energy storage system (HESS) has emerged as one of the pivotal technologies driving the revolution in green aviation and low-carbon transportation technologies, owing to its superior energy density and rapid power response capability. However, conventional control methods face difficulties in fully optimizing the compensation performance of energy storage systems while ensuring system stability. To address this challenge, this paper proposes an improved adaptive control method. By integrating a voltage outer-loop adaptive algorithm with second-order frequency division technology, the proposed approach effectively suppresses DC bus voltage fluctuations and achieves notable capacity savings in HESS under identical compensation conditions. Bode diagram analysis demonstrates that the improved adaptive algorithm exhibits higher phase margins compared to conventional control methods, thereby significantly enhancing system stability. Furthermore, based on simulation results, this study establishes a control-in-the-loop experimental validation platform. The experimental results confirm that the proposed control method delivers substantial improvements in both HESS capacity configuration and system stability, verifying its effectiveness in practical applications.
- 25 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Aerospace and Electronic Systems
- Vol. 62 (00189251) , 2321-2335
Enhanced Power Allocation Strategy of Hybrid Energy Storage System for MEA
The aviation hybrid energy storage system (HESS) has emerged as one of the pivotal technologies driving the revolution in green aviation and low-carbon transportation technologies, owing to its superior energy density and rapid power response capability. However, conventional control methods face difficulties in fully optimizing the compensation performance of energy storage systems while ensuring system stability. To address this challenge, this paper proposes an improved adaptive control method. By integrating a voltage outer-loop adaptive algorithm with second-order frequency division technology, the proposed approach effectively suppresses DC bus voltage fluctuations and achieves notable capacity savings in HESS under identical compensation conditions. Bode diagram analysis demonstrates that the improved adaptive algorithm exhibits higher phase margins compared to conventional control methods, thereby significantly enhancing system stability. Furthermore, based on simulation results, this study establishes a control-in-the-loop experimental validation platform. The experimental results confirm that the proposed control method delivers substantial improvements in both HESS capacity configuration and system stability, verifying its effectiveness in practical applications.