Tianci Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tianci Li has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Guangyu Sun
3 shared publicationsQian Li
2 shared publicationsRuiming Liu
Kashi University
1 shared publication- Ruiming Liu
Department of Geotechnical Engineering, Nanjing Hydraulic Research Institute, Nanjing, China
1 shared publication Tianci Li
1 shared publication- Wujie Sun
Zhonglu Construction (Yunnan) Company Limited, Kunming 650500, China
1 shared publication
Latest Publications
- 2 October 2026
- Published by Elsevier in Structures
- Vol. 93
Multi-objective optimization method for hybrid isolation systems using explicit seismic response prediction
- 2 October 2026
- Published by Elsevier in Structures
- Vol. 93
Multi-objective optimization method for hybrid isolation systems using explicit seismic response prediction
- Open Access
- 17 June 2026
- Published by Springer Nature in Research Square
Multi-objective optimization method for hybrid isolation systems using explicit seismic response prediction
In highly seismic regions, a hybrid isolation system integrating isolators and viscous dampers can achieve both isolation efficiency and displacement control. However, the quantitative design of damper parameters lacks theoretical guidance. To address this bottleneck, this study proposes a multi-objective optimization design method balancing isolation-layer displacement and total shear control. First, based on the energy balance equation, explicit mappings of the displacement response ratio and shear response ratio versus the added damping ratio are derived. These mappings allow direct estimation of structural responses. Then, a design framework based on minimizing a weighted sum function is established, from which the optimal added damping ratio can be determined according to engineering needs. Case validation demonstrates that the explicit formulas yield predictions within a 20% deviation compared with time-history analysis results, meeting the accuracy requirements of preliminary design. The weighting method effectively balances displacement and shear control, significantly reducing the design iteration cost caused by repeated trial computations in time-history analysis. This method offers a practical tool for the preliminary design of low-to-medium-rise isolated structures and lays a methodological foundation for the analytical optimization design of complex isolation systems.
- 17 June 2026
- Published by Springer Nature in Research Square
Open AccessMulti-objective optimization method for hybrid isolation systems using explicit seismic response prediction
In highly seismic regions, a hybrid isolation system integrating isolators and viscous dampers can achieve both isolation efficiency and displacement control. However, the quantitative design of damper parameters lacks theoretical guidance. To address this bottleneck, this study proposes a multi-objective optimization design method balancing isolation-layer displacement and total shear control. First, based on the energy balance equation, explicit mappings of the displacement response ratio and shear response ratio versus the added damping ratio are derived. These mappings allow direct estimation of structural responses. Then, a design framework based on minimizing a weighted sum function is established, from which the optimal added damping ratio can be determined according to engineering needs. Case validation demonstrates that the explicit formulas yield predictions within a 20% deviation compared with time-history analysis results, meeting the accuracy requirements of preliminary design. The weighting method effectively balances displacement and shear control, significantly reducing the design iteration cost caused by repeated trial computations in time-history analysis. This method offers a practical tool for the preliminary design of low-to-medium-rise isolated structures and lays a methodological foundation for the analytical optimization design of complex isolation systems.
- Open Access
Seismic Performance of High-Rise Shear Walls with Hybrid Control: Sparse Isolation Bearings and Viscous Fluid Dampers
To tackle the limitations of conventional seismic design in high-intensity zones, as well as the challenges of inadequate isolation efficiency, excessive bearing displacement, and tensile stress in seismically isolated high-rise structures, this study presents a systematic solution for high-rise shear wall structures in seismic intensity 8 zones. The solution features a sparse isolator layout strategy, reducing isolator count by 40% to lower stiffness, while adding viscous dampers in the isolation layer for enhanced displacement control. Comparative nonlinear time history analyses were conducted to evaluate the inter-story shear distribution, energy dissipation allocation, and isolator responses. The results show that (1) the sparse layout achieves the best performance in controlling the bottom shear ratio and Maximum Considered Earthquake (MCE)-level responses (including displacement and tensile stress); (2) viscous dampers significantly reduce the shear forces in the lower stories and the energy dissipation of both isolators and the superstructure; (3) the combined strategy successfully resolves the issues of excessive isolator displacement and tensile stress under MCE. This research offers a standardized, economical, and highly resilient technical approach for seismically isolated high-rise projects in high-intensity seismic regions.
Open AccessSeismic Performance of High-Rise Shear Walls with Hybrid Control: Sparse Isolation Bearings and Viscous Fluid Dampers
To tackle the limitations of conventional seismic design in high-intensity zones, as well as the challenges of inadequate isolation efficiency, excessive bearing displacement, and tensile stress in seismically isolated high-rise structures, this study presents a systematic solution for high-rise shear wall structures in seismic intensity 8 zones. The solution features a sparse isolator layout strategy, reducing isolator count by 40% to lower stiffness, while adding viscous dampers in the isolation layer for enhanced displacement control. Comparative nonlinear time history analyses were conducted to evaluate the inter-story shear distribution, energy dissipation allocation, and isolator responses. The results show that (1) the sparse layout achieves the best performance in controlling the bottom shear ratio and Maximum Considered Earthquake (MCE)-level responses (including displacement and tensile stress); (2) viscous dampers significantly reduce the shear forces in the lower stories and the energy dissipation of both isolators and the superstructure; (3) the combined strategy successfully resolves the issues of excessive isolator displacement and tensile stress under MCE. This research offers a standardized, economical, and highly resilient technical approach for seismically isolated high-rise projects in high-intensity seismic regions.