Samuel Guigo
Samuel Guigo has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Martial Defoort
Univ. Grenoble Alpes, CNRS, Grenoble INP, TIMA, Grenoble, France
2 shared publications - Olivier Freychet
Univ. Grenoble Alpes, CEA, LETI, F-38000 Grenoble, France
2 shared publications - Skandar Basrour
Univ. Grenoble Alpes, CNRS, Grenoble INP, TIMA, Grenoble, France
2 shared publications - Valérie Burdin
IMT-Atlantique
2 shared publications - Ahmed Ali El Ahmadi
LBA Aix Marseille Univ Univ Gustave Eiffel Marseille France
1 shared publication Alexis Ruimy
Aix Marseille University, LIIE, Marseille, France; Aix Marseille University, CERIMED, Marseille, France; Interventional Radiology Section, Department of Medical Imaging, University Hospital Timone, AP-HM, 13005 Marseille, France
1 shared publication
Latest Publications
- Open Access
- 10 July 2026
- Published by Elsevier in Ultrasonics
- Vol. 168, 108231
Powering smart orthopedic implants using acoustic waves: An ex vivo study
- 10 July 2026
- Published by Elsevier in Ultrasonics
- Vol. 168, 108231
Open AccessPowering smart orthopedic implants using acoustic waves: An ex vivo study
- Open Access
- 9 April 2026
- Published by Elsevier in SSRN Electronic Journal
Powering smart orthopedic implants using acoustic waves: an ex vivo study
This work experimentally investigates the feasibility of acoustic power transfer for battery-free full-metal smart orthopedic implants. Two receiver placements were evaluated on both knees of a human cadaver: a stem placement, where the acoustic path includes cancellous bone, and a tray placement, where the acoustic path avoids bone but integration constraints are more stringent. Receivers with resonance frequencies between 250 kHz and 2 MHz were designed using finite element simulations, analytical modelling, and phantom experiments. Measurements show that increasing frequency significantly reduces transmitted power due to higher attenuation in cancellous bone. It was shown that up to 29 mW and 20 mW of power could be transferred with the stem and tray placement, respectively, while respecting acoustic intensity and mechanical index exposure limits. This work demonstrates the feasibility of milliwatt-level acoustic powering of smart orthopedic implants while highlighting challenges related to transmitter alignment and narrow operating bandwidth.
- 9 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPowering smart orthopedic implants using acoustic waves: an ex vivo study
This work experimentally investigates the feasibility of acoustic power transfer for battery-free full-metal smart orthopedic implants. Two receiver placements were evaluated on both knees of a human cadaver: a stem placement, where the acoustic path includes cancellous bone, and a tray placement, where the acoustic path avoids bone but integration constraints are more stringent. Receivers with resonance frequencies between 250 kHz and 2 MHz were designed using finite element simulations, analytical modelling, and phantom experiments. Measurements show that increasing frequency significantly reduces transmitted power due to higher attenuation in cancellous bone. It was shown that up to 29 mW and 20 mW of power could be transferred with the stem and tray placement, respectively, while respecting acoustic intensity and mechanical index exposure limits. This work demonstrates the feasibility of milliwatt-level acoustic powering of smart orthopedic implants while highlighting challenges related to transmitter alignment and narrow operating bandwidth.
- Open Access
- 2 January 2026
- Published by Elsevier in Journal Of Neuroradiology
- Vol. 53 (1) , 101408
Tantalum sedimentation in Onyx® syringes: An in-vitro study of agitation strategies to maintain fluoroscopic visibility
- 2 January 2026
- Published by Elsevier in Journal Of Neuroradiology
- Vol. 53 (1) , 101408
Open AccessTantalum sedimentation in Onyx® syringes: An in-vitro study of agitation strategies to maintain fluoroscopic visibility