Zhiwei Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhiwei Huang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Fengqiu Xu
Electronic Information School, Wuhan University, Wuhan, China
2 shared publications - Xianze Xu
Electronic Information School, Wuhan University, Wuhan, China
2 shared publications - Yibo Wang
Electronic Information School, Wuhan University, Wuhan, China
2 shared publications - Chun Liu
Electronic Information School, Wuhan University, Wuhan, China
1 shared publication
Latest Publications
- 26 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-13
Hall-Array-Based Position and Posture Measurement of Mover in MLPM With Extendable Stroke
The high-precision motion control of magnetic levitation planar motor (MLPM) relies on the real-time and accurate measurement of the position and posture (P & P) of the mover, in which the 2-D Halbach array is widely employed as the magnetic field generating unit. This paper proposes a real-time P & P measurement method based on Hall sensor arrays for rapid estimation of the six-degree-of-freedom (6-DOF) P & P of the mover within a small-angle rotational range, by exploiting the magnetic field distribution characteristics of the 2-D Halbach array. An optimal sensor placement strategy was developed by minimizing the influence of current-carrying coils in the MLPM stator. By exploiting the sinusoidal distribution characteristics of the magnetic field generated by the Halbach array, the P & P estimation problem was transformed into an analytical solution framework involving inverse trigonometric and logarithmic functions, which enables real-time computation. The proposed method was implemented and validated through physical experiments, and experimental results demonstrate that the proposed method achieves high accuracy, with a root mean square error (RMSE) of less than 0.013 mm and a maximum error below 0.052 mm for position estimation, and a RMSE under 0.011° with a maximum error below 0.063° for rotation estimation. In addition, real-time implementation on the NI controller shows that the computation, is completed within approximately 40 μs, satisfying the requirements of closed-loop control.
- 26 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-13
Hall-Array-Based Position and Posture Measurement of Mover in MLPM With Extendable Stroke
The high-precision motion control of magnetic levitation planar motor (MLPM) relies on the real-time and accurate measurement of the position and posture (P & P) of the mover, in which the 2-D Halbach array is widely employed as the magnetic field generating unit. This paper proposes a real-time P & P measurement method based on Hall sensor arrays for rapid estimation of the six-degree-of-freedom (6-DOF) P & P of the mover within a small-angle rotational range, by exploiting the magnetic field distribution characteristics of the 2-D Halbach array. An optimal sensor placement strategy was developed by minimizing the influence of current-carrying coils in the MLPM stator. By exploiting the sinusoidal distribution characteristics of the magnetic field generated by the Halbach array, the P & P estimation problem was transformed into an analytical solution framework involving inverse trigonometric and logarithmic functions, which enables real-time computation. The proposed method was implemented and validated through physical experiments, and experimental results demonstrate that the proposed method achieves high accuracy, with a root mean square error (RMSE) of less than 0.013 mm and a maximum error below 0.052 mm for position estimation, and a RMSE under 0.011° with a maximum error below 0.063° for rotation estimation. In addition, real-time implementation on the NI controller shows that the computation, is completed within approximately 40 μs, satisfying the requirements of closed-loop control.
- 13 January 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (4) , 045002
A low-cost and high-efficiency magnetic levitation stage based on Hall sensors
Emerging maglev stage systems demonstrate significant ability in high-end control industrial manufacturing characterized by their non-contact operation and multi-degree-of-freedom motion capabilities. Conventional sensing and driving systems for maglev stages, however, are typically cost-prohibitive, limiting their broader application potential. To this end, this paper develops a low-cost and effective maglev stage system utilizing Hall sensors to construct the measurement system and high-efficiency H-bridge for current supply. Spatial positioning relationships are analyzed to define the motor position measurement strategy, and non-linear errors are calibrated in the measurement system. A principle prototype is constructed and experimentally validated. The results indicate that the translational and rotational motion resolutions of the stage reach 5 μ m and 50 μ rad , respectively, with trajectory tracking performance matching that of the stage using laser displacement sensors.
- 13 January 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (4) , 045002
A low-cost and high-efficiency magnetic levitation stage based on Hall sensors
Emerging maglev stage systems demonstrate significant ability in high-end control industrial manufacturing characterized by their non-contact operation and multi-degree-of-freedom motion capabilities. Conventional sensing and driving systems for maglev stages, however, are typically cost-prohibitive, limiting their broader application potential. To this end, this paper develops a low-cost and effective maglev stage system utilizing Hall sensors to construct the measurement system and high-efficiency H-bridge for current supply. Spatial positioning relationships are analyzed to define the motor position measurement strategy, and non-linear errors are calibrated in the measurement system. A principle prototype is constructed and experimentally validated. The results indicate that the translational and rotational motion resolutions of the stage reach 5 μ m and 50 μ rad , respectively, with trajectory tracking performance matching that of the stage using laser displacement sensors.