Hui-Tong Zhai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hui-Tong Zhai has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Hui Zeng
State Key Laboratory of Dark Matter Physics, Key Laboratory for Laser Plasmas (MoE), School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai, China
2 shared publications - Li-Ming Chen
State Key Laboratory of Dark Matter Physics, Key Laboratory for Laser Plasmas (MoE), School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai, China
2 shared publications - Mingyang Zhu
Shanghai Jiao Tong University
2 shared publications - Xichen Hu
Shanghai Jiao Tong University
2 shared publications Xin Lu
Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing, China
2 shared publicationsBing-Zhan Shi
State Key Laboratory of Dark Matter Physics, Key Laboratory for Laser Plasmas (MoE), School of Physics and Astronomy, Shanghai Jiao Tong University 1 , Shanghai 200240
1 shared publication
Latest Publications
- Open Access
- 5 March 2026
- Published by Cambridge University Press (CUP) in High Power Laser Science and Engineering
- Vol. 14, e7
Efficient generation of a 100 nC electron beam via self-mode transition from LWFA to PWFA
Laser-driven plasma wakefield acceleration (LWFA) offers exceptionally high acceleration gradients and can produce high-brightness electron beams. However, the laser-to-electron energy conversion efficiency typically remains limited to a few percent. Theoretically, the self-mode transition from LWFA to beam-driven plasma wakefield acceleration (PWFA) provides a pathway for fully utilizing the laser energy. Here, we demonstrate the single-stage LPWFA (hybrid LWFA–PWFA) scheme, validated through comparative experiments using a 300 TW tightly focused laser interacting with sub-critical density nitrogen gas targets. The experiments produce an electron beam with charge of approximately 31 nC above 6 MeV and approximately 116 nC above 2 MeV. The laser-to-electron energy conversion efficiency is approximately 6.1% (>6 MeV) and 16.4% (>2 MeV), respectively. Particle-in-cell simulations confirm that the single-stage LPWFA mechanism depletes the laser energy and enables continual electron injection. This high-charge, multi-MeV electron beam has great value in the generation of high-brightness $\unicode{x3b3}$ -rays and high-flux neutron sources.- 5 March 2026
- Published by Cambridge University Press (CUP) in High Power Laser Science and Engineering
- Vol. 14, e7
Open AccessEfficient generation of a 100 nC electron beam via self-mode transition from LWFA to PWFA
Laser-driven plasma wakefield acceleration (LWFA) offers exceptionally high acceleration gradients and can produce high-brightness electron beams. However, the laser-to-electron energy conversion efficiency typically remains limited to a few percent. Theoretically, the self-mode transition from LWFA to beam-driven plasma wakefield acceleration (PWFA) provides a pathway for fully utilizing the laser energy. Here, we demonstrate the single-stage LPWFA (hybrid LWFA–PWFA) scheme, validated through comparative experiments using a 300 TW tightly focused laser interacting with sub-critical density nitrogen gas targets. The experiments produce an electron beam with charge of approximately 31 nC above 6 MeV and approximately 116 nC above 2 MeV. The laser-to-electron energy conversion efficiency is approximately 6.1% (>6 MeV) and 16.4% (>2 MeV), respectively. Particle-in-cell simulations confirm that the single-stage LPWFA mechanism depletes the laser energy and enables continual electron injection. This high-charge, multi-MeV electron beam has great value in the generation of high-brightness $\unicode{x3b3}$ -rays and high-flux neutron sources. - 1 December 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (12)
Tabletop pulsed x-ray ghost imaging with a single-pixel detector
Although “ghost” imaging has seen remarkable advances since it was first studied 30 years ago, there have been few studies on x-ray ghost imaging (XGI) due to technical difficulties. A chief potential advantage of XGI is that imaging can be achieved with much lower radiation intensity. However, in previous XGI experiments with continuous wave x-ray illumination, the total sampling time was actually quite long, leading to additional radiation dose accumulation. In this paper, we report a proof-of-concept experiment using a high-sensitivity single-pixel detector together with a simple tabletop x-ray source followed by an adjustable mechanical shutter, which could reduce the total exposure time to as little as 5 ms. Imaging was realized with a spatial resolution of 100 μm under a low radiation dose. The influence of x-ray tube current, sampling frequency, and exposure times on image quality was examined. Our experiment illustrates a practical method for low-radiation dose ghost imaging and provides valuable reference data for the future development of medical XGI cameras.
- 1 December 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (12)
Tabletop pulsed x-ray ghost imaging with a single-pixel detector
Although “ghost” imaging has seen remarkable advances since it was first studied 30 years ago, there have been few studies on x-ray ghost imaging (XGI) due to technical difficulties. A chief potential advantage of XGI is that imaging can be achieved with much lower radiation intensity. However, in previous XGI experiments with continuous wave x-ray illumination, the total sampling time was actually quite long, leading to additional radiation dose accumulation. In this paper, we report a proof-of-concept experiment using a high-sensitivity single-pixel detector together with a simple tabletop x-ray source followed by an adjustable mechanical shutter, which could reduce the total exposure time to as little as 5 ms. Imaging was realized with a spatial resolution of 100 μm under a low radiation dose. The influence of x-ray tube current, sampling frequency, and exposure times on image quality was examined. Our experiment illustrates a practical method for low-radiation dose ghost imaging and provides valuable reference data for the future development of medical XGI cameras.