Luca Alberti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Luca Alberti has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Alberto Favaro
IRCCS Humanitas Research Hospital
1 shared publication - Francesco Iacono
IRCCS Humanitas Research Hospital, Via Manzoni 56, Rozzano, 20089 Milan, Italy
1 shared publication - Gregorio Alberto
IRCCS Humanitas Research Hospital, Rozzano, Italy
1 shared publication - Maurilio Marcacci
Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Pieve Emanuele, 20072 Milan, Italy
1 shared publication - Simonetta Resta
IRCCS Humanitas Research Hospital
1 shared publication - Tommaso Bonanzinga
IRCCS Humanitas Research Hospital Rozzano Milan Italy
1 shared publication
Latest Publications
- Open Access
- 6 January 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (2) , 404
A Novel Surgical Technique for Total Knee Arthroplasty Using the Femoral Trochlear Bisector as a New Landmark: Technical Description and Early Clinical Results
Background/Objectives: This study introduces and evaluates a novel surgical technique for total knee arthroplasty (TKA) that uses the trochlear groove bisector (TGB) as an anatomical landmark to achieve kinematic alignment of the femoral component in the coronal plane. The aim of the present retrospective observational analysis was to assess the reproducibility and accuracy of this approach and to report preliminary clinical outcomes. Methods: Twenty-eight TKA procedures were performed using the TGB-guided alignment technique. Preoperative planning and postoperative assessments were conducted on long-leg weight-bearing radiographs to measure the agreement between planned and achieved alignment, analysed using Bland–Altman statistics. Functional outcomes were evaluated at 12 months with the Knee Society Score (KSS), Forgotten Joint Score (FJS), and patient satisfaction. Results: The mean difference between planned and post-operative mLDFA was −0.3° ± 0.65°, with a root mean square error (RMSE) of 0.7°, demonstrating high accuracy and reproducibility. Postoperative outcomes showed mean KSS (knee = 89.6, function = 91.4), FJS = 69.6 ± 12, mean flexion = 124.6°, and mean HKA = 178°. Ninety percent of patients reported being satisfied or very satisfied at 12 months. Conclusions: The TGB-based technique offers a reliable, easily applicable method for restoring native femoral alignment in TKA using standard instrumentation. It allows accurate prediction of postoperative alignment and achieves favourable early functional outcomes. While currently limited to moderate varus deformities, future developments integrating 3D or CT-based planning may extend its applicability to more complex cases.
- 6 January 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (2) , 404
Open AccessA Novel Surgical Technique for Total Knee Arthroplasty Using the Femoral Trochlear Bisector as a New Landmark: Technical Description and Early Clinical Results
Background/Objectives: This study introduces and evaluates a novel surgical technique for total knee arthroplasty (TKA) that uses the trochlear groove bisector (TGB) as an anatomical landmark to achieve kinematic alignment of the femoral component in the coronal plane. The aim of the present retrospective observational analysis was to assess the reproducibility and accuracy of this approach and to report preliminary clinical outcomes. Methods: Twenty-eight TKA procedures were performed using the TGB-guided alignment technique. Preoperative planning and postoperative assessments were conducted on long-leg weight-bearing radiographs to measure the agreement between planned and achieved alignment, analysed using Bland–Altman statistics. Functional outcomes were evaluated at 12 months with the Knee Society Score (KSS), Forgotten Joint Score (FJS), and patient satisfaction. Results: The mean difference between planned and post-operative mLDFA was −0.3° ± 0.65°, with a root mean square error (RMSE) of 0.7°, demonstrating high accuracy and reproducibility. Postoperative outcomes showed mean KSS (knee = 89.6, function = 91.4), FJS = 69.6 ± 12, mean flexion = 124.6°, and mean HKA = 178°. Ninety percent of patients reported being satisfied or very satisfied at 12 months. Conclusions: The TGB-based technique offers a reliable, easily applicable method for restoring native femoral alignment in TKA using standard instrumentation. It allows accurate prediction of postoperative alignment and achieves favourable early functional outcomes. While currently limited to moderate varus deformities, future developments integrating 3D or CT-based planning may extend its applicability to more complex cases.