Hatem H. Alatroush
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hatem H. Alatroush has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed I Elsayed
Critical Care Medicine, Faculty of Medicine, Cairo University, Cairo, Egypt
1 shared publication Emad Eldeen Omar
1 shared publication- Hanan Zaghla
Critical Care Medicine, Faculty of Medicine, Cairo University, Cairo, Egypt
1 shared publication - Mahmoud Mohamed Kenawy
Critical Care Medicine, Faculty of Medicine, Cairo University, Cairo, Egypt
1 shared publication - Mamdouh Kotb1 shared publication
- Moataz F. Ashmawy
Critical Care Medicine, Faculty of Medicine, Cairo University, Cairo, Egypt
1 shared publication
Latest Publications
- Open Access
- 2 April 2026
- Published by Springer Nature in The Egyptian Journal of Critical Care Medicine
- Vol. 13 (1)
Pulse contour analysis versus transthoracic echocardiography in assessment of cardiac output in patients with low cardiac output syndrome post cardiac surgery
Background: Low cardiac output syndrome (LCOS) is a critical postoperative complication following cardiac surgery, leading to increased morbidity and mortality. Aim: This study aimed to evaluate the reliability of pulse contour analysis (PCA) using the Flotrac EV1000 system compared with transthoracic echocardiography (TTE) for Cardiac output (CO) measurement in LCOS patients. Methods: A single-center, prospective observational study was conducted on 50 patients with LCOS post-cardiac surgery. CO was measured using both TTE and PCA. Hemodynamic, clinical, and biochemical parameters were recorded, and correlations between CO measurements and clinical variables were assessed. Results: The study population had a mean age of 52.2 ± 11.3 years, with 68% males and 60% classified as obese. Both PCA and TTE confirmed low cardiac output (PCA: 2.42 ± 0.56 L/min; TTE: 2.48 ± 0.58 L/min) with a very strong correlation between the two methods ( r = 0.97, p < 0.001). Cardiac output positively correlated with body size, blood pressure, urine output, and central venous oxygen saturation, while negative correlations were noted with urea, creatinine, and lactate levels. These findings highlight the association between hemodynamic compromise and renal dysfunction in LCOS. Conclusion: Pulse contour analysis provides a reliable, continuous alternative to transthoracic echocardiography for cardiac output monitoring in LCOS patients post-cardiac surgery. Its real-time capability enhances clinical decision-making and supports timely interventions in the ICU setting.
- 2 April 2026
- Published by Springer Nature in The Egyptian Journal of Critical Care Medicine
- Vol. 13 (1)
Open AccessPulse contour analysis versus transthoracic echocardiography in assessment of cardiac output in patients with low cardiac output syndrome post cardiac surgery
Background: Low cardiac output syndrome (LCOS) is a critical postoperative complication following cardiac surgery, leading to increased morbidity and mortality. Aim: This study aimed to evaluate the reliability of pulse contour analysis (PCA) using the Flotrac EV1000 system compared with transthoracic echocardiography (TTE) for Cardiac output (CO) measurement in LCOS patients. Methods: A single-center, prospective observational study was conducted on 50 patients with LCOS post-cardiac surgery. CO was measured using both TTE and PCA. Hemodynamic, clinical, and biochemical parameters were recorded, and correlations between CO measurements and clinical variables were assessed. Results: The study population had a mean age of 52.2 ± 11.3 years, with 68% males and 60% classified as obese. Both PCA and TTE confirmed low cardiac output (PCA: 2.42 ± 0.56 L/min; TTE: 2.48 ± 0.58 L/min) with a very strong correlation between the two methods ( r = 0.97, p < 0.001). Cardiac output positively correlated with body size, blood pressure, urine output, and central venous oxygen saturation, while negative correlations were noted with urea, creatinine, and lactate levels. These findings highlight the association between hemodynamic compromise and renal dysfunction in LCOS. Conclusion: Pulse contour analysis provides a reliable, continuous alternative to transthoracic echocardiography for cardiac output monitoring in LCOS patients post-cardiac surgery. Its real-time capability enhances clinical decision-making and supports timely interventions in the ICU setting.
- Open Access
- 5 January 2026
- Published by Springer Nature in The Egyptian Journal of Critical Care Medicine
- Vol. 13 (1) , 2
Outcome of high flow nasal cannula versus non-invasive positive pressure ventilation in acute hypoxemic respiratory failure
Objectives: High-flow nasal cannula (HFNC) oxygen therapy is a recent technique delivering a high flow of heated and humidified gas. HFNC is simpler to use and apply than non-invasive ventilation (NIV). We conducted this study to assess the effect of high flow nasal cannula versus the conventional non-invasive positive pressure ventilation regarding escalation of respiratory support and mortality in acute hypoxemic patients. Methods: A total of 100 patients with acute hypoxemic respiratory failure (50 for each modality HFNC and NIPPV) were closely monitored for intubation rate, ICU length of stay, and 28 days mortality. Results: Regarding the intubation rate, there was no statistically significant difference between HFNC and NIPPV. In the HFNC group, 25 patients (50%) received invasive mechanical ventilation while 25 (50%) of others improved. In the NIPPV group, 23 patients (46%) were invasively ventilated, and 27 patients (54%) improved with P value 0.68. This also applies for ICU length of stay, as the mean value in the HFNC group was 8.76 while in NIPPV group it was 8.6, with P value of 0.7. Regarding 28-day mortality in the HFNC group, 21 (42%) patients died, and 29 (58%) patients survived. While in the NIPPV group, 19 patients (38%) died while 31 patients (62%) survived with P value of 0.68. Conclusion: High flow nasal cannula can be a comparable alternative to non-invasive positive pressure ventilation in acute hypoxemic respiratory failure with no significant differences in intubation rate and mortality.
- 5 January 2026
- Published by Springer Nature in The Egyptian Journal of Critical Care Medicine
- Vol. 13 (1) , 2
Open AccessOutcome of high flow nasal cannula versus non-invasive positive pressure ventilation in acute hypoxemic respiratory failure
Objectives: High-flow nasal cannula (HFNC) oxygen therapy is a recent technique delivering a high flow of heated and humidified gas. HFNC is simpler to use and apply than non-invasive ventilation (NIV). We conducted this study to assess the effect of high flow nasal cannula versus the conventional non-invasive positive pressure ventilation regarding escalation of respiratory support and mortality in acute hypoxemic patients. Methods: A total of 100 patients with acute hypoxemic respiratory failure (50 for each modality HFNC and NIPPV) were closely monitored for intubation rate, ICU length of stay, and 28 days mortality. Results: Regarding the intubation rate, there was no statistically significant difference between HFNC and NIPPV. In the HFNC group, 25 patients (50%) received invasive mechanical ventilation while 25 (50%) of others improved. In the NIPPV group, 23 patients (46%) were invasively ventilated, and 27 patients (54%) improved with P value 0.68. This also applies for ICU length of stay, as the mean value in the HFNC group was 8.76 while in NIPPV group it was 8.6, with P value of 0.7. Regarding 28-day mortality in the HFNC group, 21 (42%) patients died, and 29 (58%) patients survived. While in the NIPPV group, 19 patients (38%) died while 31 patients (62%) survived with P value of 0.68. Conclusion: High flow nasal cannula can be a comparable alternative to non-invasive positive pressure ventilation in acute hypoxemic respiratory failure with no significant differences in intubation rate and mortality.