Dongren Dai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dongren Dai has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jinghua Li
School of Electrical Engineering, Guangxi University, Nanning, China
2 shared publications - Wei Tian
Guangxi University, Nanning, China
2 shared publications - Bo Li
Guangxi University
1 shared publication Fei Lan
School of Electrical Engineering, Guangxi University, Nanning, China
1 shared publication- Fei Lan
Guangxi University, Nanning, China
1 shared publication - Junkun Zhang
College of Electrical and Information Engineering, Hunan University, Changsha, China
1 shared publication
Latest Publications
- 29 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-14
Two-Stage Current Limiting Method for Fault Ride-Through Enhancement of Virtual Synchronous Generator
By emulating inertia and damping, the virtual synchronous generator (VSG) enhances the dynamic support of grid frequency and voltage. However, under low-voltage faults, it is prone to severe overcurrent, power oscillations, and overload risks. To address these issues, a novel two-stage current limiting (TSCL) method is proposed in this article, which applies different limiting modes during the fault occurrence and recovery stages. Based on this, the combined effects of the active and reactive power control loops on the synchronization process under current limitation are thoroughly analyzed, and the absolute stability region (ASR) and the marginal stability region (MSR) are defined. Additionally, a transient control strategy based on power-angle characteristics is proposed to shorten synchronization time and suppress reactive power fluctuations. Finally, experimental results verify the effectiveness of the proposed method. Compared with conventional current-limiting approaches, the proposed scheme significantly reduces power oscillations and overload during fault recovery without increasing synchronization time, while maintaining strong synchronization capability.
- 29 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-14
Two-Stage Current Limiting Method for Fault Ride-Through Enhancement of Virtual Synchronous Generator
By emulating inertia and damping, the virtual synchronous generator (VSG) enhances the dynamic support of grid frequency and voltage. However, under low-voltage faults, it is prone to severe overcurrent, power oscillations, and overload risks. To address these issues, a novel two-stage current limiting (TSCL) method is proposed in this article, which applies different limiting modes during the fault occurrence and recovery stages. Based on this, the combined effects of the active and reactive power control loops on the synchronization process under current limitation are thoroughly analyzed, and the absolute stability region (ASR) and the marginal stability region (MSR) are defined. Additionally, a transient control strategy based on power-angle characteristics is proposed to shorten synchronization time and suppress reactive power fluctuations. Finally, experimental results verify the effectiveness of the proposed method. Compared with conventional current-limiting approaches, the proposed scheme significantly reduces power oscillations and overload during fault recovery without increasing synchronization time, while maintaining strong synchronization capability.
- 5 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (6) , 10255-10267
A Virtual Admittance-Based State Observer Design for Enhanced Dynamic Synchronization Performance of Virtual Synchronous Generator
The virtual resistor (VR) has positive effects on the small-signal stability of the virtual synchronous generator (VSG), but decreases the dynamic-state synchronization performance. To solve that conflict, a virtual admittance (VA)-based state observer (VABOB) is designed. First, the small-signal model of the VSG is analyzed, and it is found that the extra VR is only needed at 0 Hz to suppress the synchronous frequency resonance (SFR). The extra resistor at the synchronous frequency (SF) will decrease the dynamic response performance. Second, a state equation is designed for the accurate estimation of the SF component, and the VA without VR is designed as the output equation. Then, the state observer is deduced based on these equations. Third, the analysis of the grid voltage and frequency deviation shows the robustness of the VABOB. Furthermore, the selection principle for the observer gain is also analyzed. Simulations and experiments verify the effectiveness of the VABOB in SFR suppression and dynamic performance enhancement by reducing the R/X. The VABOB can reduce the maximum by 0.39 p.u. power overshoot when the grid voltage is sagged by 0.1 p.u., as compared to the VR-based method with R/X = 0.19. By 0.55 p.u. reactive power overshoot reduction when power given is increased from 0 to 1 p.u., as compared to the VR-based method with R/X = 0.83.
- 5 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (6) , 10255-10267
A Virtual Admittance-Based State Observer Design for Enhanced Dynamic Synchronization Performance of Virtual Synchronous Generator
The virtual resistor (VR) has positive effects on the small-signal stability of the virtual synchronous generator (VSG), but decreases the dynamic-state synchronization performance. To solve that conflict, a virtual admittance (VA)-based state observer (VABOB) is designed. First, the small-signal model of the VSG is analyzed, and it is found that the extra VR is only needed at 0 Hz to suppress the synchronous frequency resonance (SFR). The extra resistor at the synchronous frequency (SF) will decrease the dynamic response performance. Second, a state equation is designed for the accurate estimation of the SF component, and the VA without VR is designed as the output equation. Then, the state observer is deduced based on these equations. Third, the analysis of the grid voltage and frequency deviation shows the robustness of the VABOB. Furthermore, the selection principle for the observer gain is also analyzed. Simulations and experiments verify the effectiveness of the VABOB in SFR suppression and dynamic performance enhancement by reducing the R/X. The VABOB can reduce the maximum by 0.39 p.u. power overshoot when the grid voltage is sagged by 0.1 p.u., as compared to the VR-based method with R/X = 0.19. By 0.55 p.u. reactive power overshoot reduction when power given is increased from 0 to 1 p.u., as compared to the VR-based method with R/X = 0.83.