Osamu Yamaguchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Osamu Yamaguchi has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Kazuki Yoshida
Department of Radiology, Graduate School of Medicine, Ehime University, Toon 791-0295, Japan
1 shared publication - Kentaro Ohara
Department of Radiology, Ehime University Graduate School of Medicine, Toon, Japan
1 shared publication - Shota Nakano
Canon Medical Systems Corporation, Otawara 324-8550, Japan
1 shared publication - Takaaki Hosokawa
Department of Radiology, Ehime Prefectural Imabari Hospital, Imabari 794-0006, Japan
1 shared publication - Takanori Kouchi
Department of Radiology, Graduate School of Medicine, Ehime University, Toon 791-0295, Japan
1 shared publication - Teruhito Kido
Department of Radiology, Graduate School of Medicine, Ehime University, Toon 791-0295, Japan
1 shared publication
Latest Publications
- Open Access
- 7 January 2026
- Published by MDPI AG in Tomography
- Vol. 12 (1) , 7
Super-Resolution Deep Learning Reconstruction Improves Image Quality of Dynamic Myocardial Computed Tomography Perfusion Imaging
Background/Objectives: Super-resolution deep-learning reconstruction (SR-DLR) is an advanced image reconstruction technique, but its effect on dynamic myocardial computed tomography perfusion (CTP) imaging has not been evaluated. This study aimed to examine the impact of SR-DLR on image quality and perfusion parameters in dynamic myocardial CTP. Methods: Thirty-five patients who underwent dynamic myocardial CTP for coronary artery disease assessment were retrospectively analyzed. Two CTP datasets were reconstructed using hybrid iterative reconstruction (HIR) and SR-DLR. Image quality was compared qualitatively and quantitatively, including image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and edge rise slope (ERS). Equivalence of CT-derived myocardial blood flow (CT-MBF) between two reconstructions was tested using a previously reported 15% equivalence margin. Intra-patient variability of CT-MBF was evaluated using the robust coefficient of variation (rCV). Results: In the qualitative assessment, SR-DLR had significantly higher scores in contrast (4.0 vs. 2.0) and sharpness (4.5 vs. 2.5) compared with HIR (p < 0.001), while contrast scores were similar. In the quantitative assessment, SR-DLR demonstrated significantly lower image noise (19.4 vs. 29.4 HU), and improved SNR (6.1 vs. 4.1), CNR (13.7 vs. 10.9), and ERS (171.0 vs. 135.1 HU/mm) (all p < 0.001). Mean global CT-MBF was comparable (3.15 ± 0.91 mL/g/min for HIR vs. 3.18 ± 0.97 mL/g/min for SR-DLR) and equivalence was confirmed (p = 0.022). SR-DLR significantly reduced rCV compared with HIR (36.0% vs. 41.0%, p < 0.001). Conclusions: SR-DLR enhances image quality in dynamic myocardial CTP while maintaining mean global CT-MBF and reducing intra-patient variability.
- 7 January 2026
- Published by MDPI AG in Tomography
- Vol. 12 (1) , 7
Open AccessSuper-Resolution Deep Learning Reconstruction Improves Image Quality of Dynamic Myocardial Computed Tomography Perfusion Imaging
Background/Objectives: Super-resolution deep-learning reconstruction (SR-DLR) is an advanced image reconstruction technique, but its effect on dynamic myocardial computed tomography perfusion (CTP) imaging has not been evaluated. This study aimed to examine the impact of SR-DLR on image quality and perfusion parameters in dynamic myocardial CTP. Methods: Thirty-five patients who underwent dynamic myocardial CTP for coronary artery disease assessment were retrospectively analyzed. Two CTP datasets were reconstructed using hybrid iterative reconstruction (HIR) and SR-DLR. Image quality was compared qualitatively and quantitatively, including image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and edge rise slope (ERS). Equivalence of CT-derived myocardial blood flow (CT-MBF) between two reconstructions was tested using a previously reported 15% equivalence margin. Intra-patient variability of CT-MBF was evaluated using the robust coefficient of variation (rCV). Results: In the qualitative assessment, SR-DLR had significantly higher scores in contrast (4.0 vs. 2.0) and sharpness (4.5 vs. 2.5) compared with HIR (p < 0.001), while contrast scores were similar. In the quantitative assessment, SR-DLR demonstrated significantly lower image noise (19.4 vs. 29.4 HU), and improved SNR (6.1 vs. 4.1), CNR (13.7 vs. 10.9), and ERS (171.0 vs. 135.1 HU/mm) (all p < 0.001). Mean global CT-MBF was comparable (3.15 ± 0.91 mL/g/min for HIR vs. 3.18 ± 0.97 mL/g/min for SR-DLR) and equivalence was confirmed (p = 0.022). SR-DLR significantly reduced rCV compared with HIR (36.0% vs. 41.0%, p < 0.001). Conclusions: SR-DLR enhances image quality in dynamic myocardial CTP while maintaining mean global CT-MBF and reducing intra-patient variability.