RKRobert Krumm

Robert Krumm

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Robert Krumm has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development and Validation of a Generative Artificial Intelligence-Based Pipeline for Automated Clinical Data Extraction From Electronic Health Records: Technical Implementation Study

    by Marvin N Carlisle, William A Pace, Andrew W Liu, Robert Krumm, Janet E Cowan, Peter R Carroll, Matthew R Cooperberg, Anobel Y Odisho

    Background: The manual abstraction of unstructured clinical data is often necessary for granular clinical outcomes research but is time consuming and can be of variable quality. Large language models (LLMs) show promise in medical data extraction yet integrating them into research workflows remains challenging and poorly described. Objective: This study aimed to develop and integrate an LLM-based system for automated data extraction from unstructured electronic health record (EHR) text reports within an established clinical outcomes database. Methods: We implemented a generative artificial intelligence pipeline (UODBLLM) utilizing a flexible language model interface that supports various LLM implementations, including Health Insurance Portability and Accountability Act-compliant cloud services and local open-source models. We used extensible markup language (XML)-structured prompts and integrated using an open database connectivity interface to generate structured data from clinical documentation in the EHR. We evaluated the UODBLLM’s performance on the completion rate, processing time, and extraction capabilities across multiple clinical data elements, including quantitative measurements, categorical assessments, and anatomical descriptions, using sample magnetic resonance imaging (MRI) reports as test cases. System reliability was tested across multiple batches to assess scalability and consistency. Results: Piloted against MRI reports, UODBLLM processed 1800 clinical documents with a 100% completion rate and an average processing time of 8.90 seconds per report. The token utilization averaged 2692 tokens per report, with an input-to-output ratio of approximately 13:2, resulting in a processing cost of US $0.009 per report. UODBLLM had consistent performance across 18 batches of 100 reports each and completed all processing in 4.45 hours. From each report, UODBLLM extracted 16 structured clinical elements, including prostate volume, prostate-specific antigen values, Prostate Imaging Reporting and Data System scores, clinical staging, and anatomical assessments. All extracted data were automatically validated against predefined schemas and stored in standardized JSON format. Conclusions: We demonstrated the successful integration of an LLM-based extraction system within an existing clinical outcomes database, achieving rapid, comprehensive data extraction at minimal cost. UODBLLM provides a scalable, efficient solution for automating clinical data extraction while maintaining protected health information security. This approach could significantly accelerate research timelines and expand feasible clinical studies, particularly for large-scale database projects.


  • Generative Artificial Intelligence Successfully Automates Data Extraction From Unstructured Magnetic Resonance Imaging Reports: Feasibility in Prostate Cancer Care

    by Anobel Y. Odisho, Andrew W. Liu, William A. Pace, Marvin N. Carlisle, Robert Krumm, Janet E. Cowan, Peter R. Carroll, Matthew R. Cooperberg

    PURPOSE: Radiology reports are stored as plain text in most electronic health records, rendering the data computationally inaccessible. Large language models are powerful tools for analyzing unstructured text but relatively untested in urologic oncology. We aimed to develop a pipeline to extract data from plain text prostate magnetic resonance imaging (MRI) reports using GPT4.0 and compare the accuracy to manually abstracted data. METHODS: We developed a data pipeline using a secure, enterprise-wide deployment of OpenAI's GPT-4.0 to automatically extract data elements from prostate MRI report text when presented with prostate MRI reports. Identical prompts and reports were sent multiple times to determine response variability. We extracted 15 data elements per report and compared accuracy to a manually abstracted gold standard. RESULTS: Across 424 prostate MRI reports, GPT-4.0 response accuracy was consistently above 95%. Individual field accuracies were 98.3% (96.3%-99.3%) for prostate-specific antigen density, 97.4% (95.4%-98.7%) for extracapsular extension, and 98.1% (96.3%-99.2%) for TNM stage, and had a median of 98.1% (96.3%-99.2%), a mean of 97.2% (95.2%-98.3%), and a range of 99.8% (98.7%-100.0%) for number of suspicious lesions to 87.7% (84.2%-90.7%) for identification of lesion location in the base of the prostate. Response variability over five repeated runs ranged from 0.14% to 3.61%, differed based on the data element extracted ( P < .001), and was inversely correlated with accuracy ( P < .001). In disagreements between manual and GPT-4.0 extracted data, GPT-4.0 responses were more often deemed correct by an additional reviewer. CONCLUSION: GPT-4.0 had high accuracy with low variability in extracting data points from prostate cancer MRI reports with low upfront programming requirements. This represents an effective tool to expedite medical data extraction for clinical and research use cases.