Paolo Artina
Research Subjects
Research Interests
Paolo Artina has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Anthony Turner
London Sport Institute, Middlesex University, London NW4 4BT, UK
3 shared publications - Chris Bishop
London Sport Institute, Middlesex University, London NW4 4BT, UK
2 shared publications - Luca Maestroni
London Sports Institute, Middlesex University, Stone X Stadium, Greenlands Lane, London NW4 4BT, UK
2 shared publications - Fabio Civera
ReAct, Via Madonna della Neve, 24, 24121 Bergamo, Italy
1 shared publication - Filippo Beretta
School of Medicine and Surgery, Università degli Studi Milano Bicocca, 20126 Milan, Italy
1 shared publication - Francesco Bettariga
Exercise Medicine Research Institute, Edith Cowan University, Perth, Australia
1 shared publication
Latest Publications
- Open Access
- 1 June 2026
- Published by Elsevier in SSRN Electronic Journal
Comparison of Isometric, Isotonic and Endurance Calf Tests in Healthy Subjects
The soleus and gastrocnemius muscles play a central role in locomotion and sports performance, yet standardized protocols for assessing dynamic plantar flexor strength remain limited. The 5RM Seated Heel Raise Test may offer a practical assessment method, but its reliability and its relationship with commonly used isometric and endurance tests have not been established. Twenty-eight recreationally active males completed three unilateral tests: the Seated Isometric Plantar Flexors Test, the 5RM Seated Heel Raise Test, and the Heel Raise Test. Intra-session reliability was assessed using intraclass correlation coefficients, coefficient of variation, and standard error of measurement. Linear mixed models evaluated the effect of limb dominance, and multiple regression examined the relationships among the tests. The 5RM Seated Heel Raise Test demonstrated excellent reliability (ICC > 0.90, CV ≤ 10%), exceeding that of the other assessments, and limb dominance had no significant effect on performance. Regression analysis showed that the Seated Isometric Plantar Flexors Test and the Heel Raise Test explained 30.1% of the variance in the 5RM Seated Heel Raise Test (p < 0.001). These findings indicate that the 5RM Seated Heel Raise Test is a reliable and practical method for assessing plantar flexor strength. Compared with the Seated Isometric Plantar Flexors Test and the Heel Raise Test, it provides a more accurate evaluation of relative strength across the full range of ankle excursion, supporting its potential utility for performance monitoring and rehabilitation assessment. Statistical significance was set at p ≤ 0.05.
- 1 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessComparison of Isometric, Isotonic and Endurance Calf Tests in Healthy Subjects
The soleus and gastrocnemius muscles play a central role in locomotion and sports performance, yet standardized protocols for assessing dynamic plantar flexor strength remain limited. The 5RM Seated Heel Raise Test may offer a practical assessment method, but its reliability and its relationship with commonly used isometric and endurance tests have not been established. Twenty-eight recreationally active males completed three unilateral tests: the Seated Isometric Plantar Flexors Test, the 5RM Seated Heel Raise Test, and the Heel Raise Test. Intra-session reliability was assessed using intraclass correlation coefficients, coefficient of variation, and standard error of measurement. Linear mixed models evaluated the effect of limb dominance, and multiple regression examined the relationships among the tests. The 5RM Seated Heel Raise Test demonstrated excellent reliability (ICC > 0.90, CV ≤ 10%), exceeding that of the other assessments, and limb dominance had no significant effect on performance. Regression analysis showed that the Seated Isometric Plantar Flexors Test and the Heel Raise Test explained 30.1% of the variance in the 5RM Seated Heel Raise Test (p < 0.001). These findings indicate that the 5RM Seated Heel Raise Test is a reliable and practical method for assessing plantar flexor strength. Compared with the Seated Isometric Plantar Flexors Test and the Heel Raise Test, it provides a more accurate evaluation of relative strength across the full range of ankle excursion, supporting its potential utility for performance monitoring and rehabilitation assessment. Statistical significance was set at p ≤ 0.05.
- Open Access
- 9 April 2026
- Published by SAGE Publications in International Journal of Sports Science & Coaching
- Vol. 21 (4) , 2649-2681
Calf capacity measurements in healthy populations: A systematic review
Following PRISMA 2020 guidelines and registered in PROSPERO (CRD42025638986), the review included a comprehensive search of three databases, along with citation tracking and manual reference checks conducted in February 2025. Sixty-five peer-reviewed studies were included, encompassing a total of 3020 participants aged 18–65. The review focused on objective measures of plantar flexor capacity, such as force, torque, and repetition maximum, and considered studies that reported psychometric properties. Endurance was mostly assessed using heel raise tests. These showed high intra-session reliability (intraclass correlation coefficient (ICC) ranging from 0.77 to 0.97), but results varied significantly between individuals. Isometric and isokinetic tests also demonstrated good-to-excellent reliability (ICC 0.74–0.99), although the protocols used were highly variable across studies. Isotonic testing was the least frequently employed method. In conclusion, while isokinetic and isometric tests offer reliable assessments, their use is limited by accessibility and inconsistent protocols. The heel raise test remains a popular method for evaluating endurance but suffers from a lack of standardization. Isotonic testing is underutilized and presents an opportunity for further methodological development.
- 9 April 2026
- Published by SAGE Publications in International Journal of Sports Science & Coaching
- Vol. 21 (4) , 2649-2681
Open AccessCalf capacity measurements in healthy populations: A systematic review
Following PRISMA 2020 guidelines and registered in PROSPERO (CRD42025638986), the review included a comprehensive search of three databases, along with citation tracking and manual reference checks conducted in February 2025. Sixty-five peer-reviewed studies were included, encompassing a total of 3020 participants aged 18–65. The review focused on objective measures of plantar flexor capacity, such as force, torque, and repetition maximum, and considered studies that reported psychometric properties. Endurance was mostly assessed using heel raise tests. These showed high intra-session reliability (intraclass correlation coefficient (ICC) ranging from 0.77 to 0.97), but results varied significantly between individuals. Isometric and isokinetic tests also demonstrated good-to-excellent reliability (ICC 0.74–0.99), although the protocols used were highly variable across studies. Isotonic testing was the least frequently employed method. In conclusion, while isokinetic and isometric tests offer reliable assessments, their use is limited by accessibility and inconsistent protocols. The heel raise test remains a popular method for evaluating endurance but suffers from a lack of standardization. Isotonic testing is underutilized and presents an opportunity for further methodological development.
- Open Access
- 8 January 2026
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 11 (1) , 29
Assessment of Rotator Cuff External Rotation: Isometric vs. Isotonic Testing Modes
Objectives: To assess intra-session reliability of isometric and isotonic shoulder external rotation (ER) strength tests and to compare their outcomes. Methods: Thirty-eight healthy subjects (19 females; 19 males; 25.7 ± 6.0 years; 175 ± 9 cm; 70.3 ± 11.4 kg) completed a shoulder ER strength assessment including Prone and Standing ER Isometric tests and Seated 5 repetition maximum (RM) ER tests. Normality was checked with the Shapiro–Wilk test. Reliability was assessed using the CV and ICC (3, k, 95% CI). Linear mixed models examined sex and dominance effects. Correlations and multiple regression tested associations between tests (p < 0.05). Results: All tests performed displayed “excellent” reliability scores (CV from 1.9 to 3.1% and ICC from 0.970 to 0.994). No significant effect of dominance was observed in any strength test. Males showed significantly higher values than females in both Prone (3.8% higher, p < 0.001) and Standing (2.7% higher, p = 0.003) isometric ER strength tests. Prone and Standing isometric tests were moderately correlated (r = 0.62, 95% CI [0.46, 0.74], p < 0.001). A regression model explained 52.4% of the variance in Seated 5 RM ER strength (R2 = 0.524, p < 0.001), with Prone isometric strength emerging as a significant predictor (β = 0.612, p < 0.001). Conclusions: This study provides previously unreported 5 RM shoulder ER strength values in healthy adults, with all included tests showing excellent reliability. Isometric measures did not fully capture isotonic ER strength. Males outperformed females in isometric tests, but no gender difference was observed in Seated 5 RM strength.
- 8 January 2026
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 11 (1) , 29
Open AccessAssessment of Rotator Cuff External Rotation: Isometric vs. Isotonic Testing Modes
Objectives: To assess intra-session reliability of isometric and isotonic shoulder external rotation (ER) strength tests and to compare their outcomes. Methods: Thirty-eight healthy subjects (19 females; 19 males; 25.7 ± 6.0 years; 175 ± 9 cm; 70.3 ± 11.4 kg) completed a shoulder ER strength assessment including Prone and Standing ER Isometric tests and Seated 5 repetition maximum (RM) ER tests. Normality was checked with the Shapiro–Wilk test. Reliability was assessed using the CV and ICC (3, k, 95% CI). Linear mixed models examined sex and dominance effects. Correlations and multiple regression tested associations between tests (p < 0.05). Results: All tests performed displayed “excellent” reliability scores (CV from 1.9 to 3.1% and ICC from 0.970 to 0.994). No significant effect of dominance was observed in any strength test. Males showed significantly higher values than females in both Prone (3.8% higher, p < 0.001) and Standing (2.7% higher, p = 0.003) isometric ER strength tests. Prone and Standing isometric tests were moderately correlated (r = 0.62, 95% CI [0.46, 0.74], p < 0.001). A regression model explained 52.4% of the variance in Seated 5 RM ER strength (R2 = 0.524, p < 0.001), with Prone isometric strength emerging as a significant predictor (β = 0.612, p < 0.001). Conclusions: This study provides previously unreported 5 RM shoulder ER strength values in healthy adults, with all included tests showing excellent reliability. Isometric measures did not fully capture isotonic ER strength. Males outperformed females in isometric tests, but no gender difference was observed in Seated 5 RM strength.