Zhi Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhi Jiang has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Can Cao
Innovative Center for Flexible Devices (iFLEX), Max Planck-NTU Joint Laboratory for Artificial Senses, School of Materials Science and Engineering, Nanyang Technological University, Singapore, Singapore
2 shared publications - Changtai Guo
Innovative Center for Flexible Devices (iFLEX), Max Planck-NTU Joint Laboratory for Artificial Senses, School of Materials Science and Engineering, Nanyang Technological University, Singapore, Singapore
2 shared publications - Feilong Zhang
Laboratory of Bio-Inspired Smart Interface Science, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
2 shared publications - Guijin Zou
Mechano-X Institute, Applied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China
2 shared publications - Huajian Gao
Mechano-X Institute, Applied Mechanics Laboratory, Department of Engineering Mechanics, Tsinghua University, Beijing, China
2 shared publications - Jing Yu
Institute for Digital Molecular Analytics and Science (IDMxS), Nanyang Technological University, 59 Nanyang Drive, Singapore 636921, Singapore
2 shared publications
Latest Publications
Cost‐Effective Ultrathin SEBS‐Ag Electrodes of Substrate‐Regulated Microcracks for Robust Skin Electrophysiology
Ultrathin wearable interfaces are essential for continuous, long‐term electrocardiogram (ECG) monitoring. However, their widespread deployment is limited by the high economic and environmental costs of gold‐based conductors and the single‐use nature of ultrathin devices. To address these challenges, a cost‐effective, silver‐based ultrathin stretchable electrode is developed by systematically tuning the mechanical stiffness and chemical polarity of polymeric substrates. Through a deep investigation into the silver embedment mechanism and crack evolution dynamics under stretch, we established the critical structure‐property relationships governing electromechanical performance. This yielded an optimized ultrathin stretchable electrode (7.6 µm) with a skin‐mimetic modulus (1.35 ± 0.03 MPa), low sheet resistance (9.26 Ω/sq), and robust cyclic stability (resistance change of ∼1.7 after 5000 cycles). The resulting device achieves conformal skin contact, enabling low‐artifact ECG monitoring over 24 h. Furthermore, integrating a robust adhesive ion‐gel interface allows the electrode to effectively suppress motion artefacts during vigorous physical activity. It sustains a high signal‐to‐noise ratio (SNR) of 29.27 ± 1.24 dB during 13 km/h running, significantly outperforming commercial Ag/AgCl electrodes that exhibit severe motion artifacts. This strategy, merging cost‐effective manufacturing with superior dynamic signal fidelity, provides a scalable and practical paradigm for ubiquitous low‐cost health monitoring systems.
Cost‐Effective Ultrathin SEBS‐Ag Electrodes of Substrate‐Regulated Microcracks for Robust Skin Electrophysiology
Ultrathin wearable interfaces are essential for continuous, long‐term electrocardiogram (ECG) monitoring. However, their widespread deployment is limited by the high economic and environmental costs of gold‐based conductors and the single‐use nature of ultrathin devices. To address these challenges, a cost‐effective, silver‐based ultrathin stretchable electrode is developed by systematically tuning the mechanical stiffness and chemical polarity of polymeric substrates. Through a deep investigation into the silver embedment mechanism and crack evolution dynamics under stretch, we established the critical structure‐property relationships governing electromechanical performance. This yielded an optimized ultrathin stretchable electrode (7.6 µm) with a skin‐mimetic modulus (1.35 ± 0.03 MPa), low sheet resistance (9.26 Ω/sq), and robust cyclic stability (resistance change of ∼1.7 after 5000 cycles). The resulting device achieves conformal skin contact, enabling low‐artifact ECG monitoring over 24 h. Furthermore, integrating a robust adhesive ion‐gel interface allows the electrode to effectively suppress motion artefacts during vigorous physical activity. It sustains a high signal‐to‐noise ratio (SNR) of 29.27 ± 1.24 dB during 13 km/h running, significantly outperforming commercial Ag/AgCl electrodes that exhibit severe motion artifacts. This strategy, merging cost‐effective manufacturing with superior dynamic signal fidelity, provides a scalable and practical paradigm for ubiquitous low‐cost health monitoring systems.
- Open Access
- 29 May 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (22) , eaed7125
Ion-shielding ultrathin encapsulation with hot-press bonded interface enables chronic stretchable bioelectronics
Stretchable physiological electrodes are indispensable for continuous, high-fidelity bio-signal monitoring, yet liquid water and ions invade nano/microscopic interfacial defects and silence signals within weeks. We introduce an ion-shielding ultrathin encapsulation that is molecularly fused to the stretchable conductor with a hot-press bonded interface to block aqueous ingress. A single-step hot pressing expels trapped air and interdiffuses polymer chains, erasing interfacial defects. The hot-press bonded interface exhibits exceptional resistance to water and ion penetration of >12 months in solution, more than 10 times longer than untreated interfaces (less than a month). Stretchable physiological electrodes with ~10-micrometer-thick encapsulation achieved stable, high-fidelity electrophysiological recordings in demanding environments, as demonstrated by continuous monitoring of cardiomyocytes for 29 days in vitro and long-term signal recording in rat spinal cords spanning 12 weeks in vivo.
- 29 May 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (22) , eaed7125
Open AccessIon-shielding ultrathin encapsulation with hot-press bonded interface enables chronic stretchable bioelectronics
Stretchable physiological electrodes are indispensable for continuous, high-fidelity bio-signal monitoring, yet liquid water and ions invade nano/microscopic interfacial defects and silence signals within weeks. We introduce an ion-shielding ultrathin encapsulation that is molecularly fused to the stretchable conductor with a hot-press bonded interface to block aqueous ingress. A single-step hot pressing expels trapped air and interdiffuses polymer chains, erasing interfacial defects. The hot-press bonded interface exhibits exceptional resistance to water and ion penetration of >12 months in solution, more than 10 times longer than untreated interfaces (less than a month). Stretchable physiological electrodes with ~10-micrometer-thick encapsulation achieved stable, high-fidelity electrophysiological recordings in demanding environments, as demonstrated by continuous monitoring of cardiomyocytes for 29 days in vitro and long-term signal recording in rat spinal cords spanning 12 weeks in vivo.
- Top Cited PapersOpen Access
- 9 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (2) , eadz1253
Ultrapliable bioelectronic interface for mechanosensitive cardiac electrophysiology
Existing bioelectronics often exhibit megapascal-scale moduli, despite the mechanosensitive nature of cardiomyocytes. Bridging the mechanical mismatch between tissue and bioelectronics is indispensable for building physiologically relevant in vitro cardiac models and advancing therapies. Here, we present Pliable Ultrathin Layered Sensing Electronics (PULSE), a platform with tissue-matched modulus (~10 kilopascals) and stretchable gold microcircuitry for long-term, high-fidelity monitoring of cardiac electrophysiology in vitro. Composed of a soft gel matrix and an ultrathin nanofilm embedded with gold circuits, our device achieves unprecedented tissue integration and preserves natural cardiomyocyte mechanics, resulting in a 140% increase in mechanical contraction and a 100% increase in electrical signals compared to conventional electronics. Cardiac tissue that grows our device exhibited enhanced drug sensitivity and response in cardiac dysfunction, revolutionizing disease modeling. By facilitating seamless interaction at the tissue-electronic interface, our platform offers a transformative perspective for advancing cardiac modeling and next-generation bioelectronic applications.
- 9 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (2) , eadz1253
Top Cited PapersOpen AccessUltrapliable bioelectronic interface for mechanosensitive cardiac electrophysiology
Existing bioelectronics often exhibit megapascal-scale moduli, despite the mechanosensitive nature of cardiomyocytes. Bridging the mechanical mismatch between tissue and bioelectronics is indispensable for building physiologically relevant in vitro cardiac models and advancing therapies. Here, we present Pliable Ultrathin Layered Sensing Electronics (PULSE), a platform with tissue-matched modulus (~10 kilopascals) and stretchable gold microcircuitry for long-term, high-fidelity monitoring of cardiac electrophysiology in vitro. Composed of a soft gel matrix and an ultrathin nanofilm embedded with gold circuits, our device achieves unprecedented tissue integration and preserves natural cardiomyocyte mechanics, resulting in a 140% increase in mechanical contraction and a 100% increase in electrical signals compared to conventional electronics. Cardiac tissue that grows our device exhibited enhanced drug sensitivity and response in cardiac dysfunction, revolutionizing disease modeling. By facilitating seamless interaction at the tissue-electronic interface, our platform offers a transformative perspective for advancing cardiac modeling and next-generation bioelectronic applications.