Chase M. Hartquist
Research Subjects
Chase M. Hartquist has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Guy M. Genin
NSF Science and Technology Center for Engineering Mechanobiology, Washington University in St. Louis, MO, USA
2 shared publications - Halle R. Lowe
Division of Neurotechnology, Department of Neurological Surgery, Washington University School of Medicine , St. Louis, MO 63110; , St. Louis, MO 63130
2 shared publications - Joshua W. Osbun
Neurosurgery, Washington University in Saint Louis School of Medicine, Saint Louis, Missouri, USA
2 shared publications - Michael Y. Qiu
Division of Neurotechnology, Department of Neurological Surgery, Washington University School of Medicine , St. Louis, MO 63110; , St. Louis, MO 63130
2 shared publications - Mohamed Adel Zayed
Washington University in St. Louis
2 shared publications - Vinay Chandrasekaran
Division of Neurotechnology, Department of Neurological Surgery, Washington University School of Medicine , St. Louis, MO 63110; , St. Louis, MO 63130
2 shared publications
Latest Publications
- 15 May 2025
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 147 (7) , 1-19
Dynamic Rigidity Control for Supportive Sheaths in Endovascular Procedures
Endovascular procedures require sheaths with contradictory mechanical properties: flexibility for navigation through tortuous vessels, yet rigidity for device delivery. Current approaches rely on multiple device exchanges, increasing procedural time, and complication risks. Here we present a novel endovascular sheath design scheme with dynamically controllable flexural rigidity along its entire length. The device incorporates axially aligned metal string arrays between inner and outer lumens, enabling transition between flexible and rigid states through suction actuation. Three-point bend testing demonstrated that actuation increases flexural rigidity from the range associated with diagnostic catheters to that associated with support sheaths. In simulated contralateral access procedures, the device reduced access time to 1/3 of the time required when using conventional approaches. in vivo porcine studies validated the sheath's ability to navigate tortuous anatomy in its flexible state and successfully support advancement of increasingly rigid therapeutic devices when actuated. Technology enables single-sheath delivery of treatment, potentially reducing procedural complexity, decreasing complication rates, and improving patient outcomes across various endovascular interventions. This design represents a promising approach to combining catheter and sheath design that benefits both peripheral and neurovascular procedures.
- 15 May 2025
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 147 (7) , 1-19
Dynamic Rigidity Control for Supportive Sheaths in Endovascular Procedures
Endovascular procedures require sheaths with contradictory mechanical properties: flexibility for navigation through tortuous vessels, yet rigidity for device delivery. Current approaches rely on multiple device exchanges, increasing procedural time, and complication risks. Here we present a novel endovascular sheath design scheme with dynamically controllable flexural rigidity along its entire length. The device incorporates axially aligned metal string arrays between inner and outer lumens, enabling transition between flexible and rigid states through suction actuation. Three-point bend testing demonstrated that actuation increases flexural rigidity from the range associated with diagnostic catheters to that associated with support sheaths. In simulated contralateral access procedures, the device reduced access time to 1/3 of the time required when using conventional approaches. in vivo porcine studies validated the sheath's ability to navigate tortuous anatomy in its flexible state and successfully support advancement of increasingly rigid therapeutic devices when actuated. Technology enables single-sheath delivery of treatment, potentially reducing procedural complexity, decreasing complication rates, and improving patient outcomes across various endovascular interventions. This design represents a promising approach to combining catheter and sheath design that benefits both peripheral and neurovascular procedures.
- Open Access
Stability of navigation in catheter-based endovascular procedures
Endovascular procedures provide surgeons and other interventionalists with minimally invasive methods to treat vascular diseases by passing guidewires, catheters, sheaths and treatment devices into the vasculature to and navigate toward a treatment site. The efficiency of this navigation affects patient outcomes, but is frequently compromised by catheter “herniation”, in which the catheter-guidewire system bulges out from the intended endovascular pathway so that the interventionalist can no longer advance it. Here, we showed herniation to be a bifurcation phenomenon that can be predicted and controlled using mechanical characterizations of catheter-guidewire systems and patientspecific clinical imaging. We demonstrated our approach in laboratory models and, retrospectively, in patients who underwent procedures involving transradial neurovascular procedures with an endovascular pathway from the wrist, up in the arm, around the aortic arch, and into the neurovasculature. Our analyses identified a mathematical navigation stability criterion that predicted herniation in all of these settings. Results show that herniation can be predicted through bifurcation analysis, and provide a framework for selecting catheter-guidewire systems to avoid herniation in specific patient anatomy.
Open AccessStability of navigation in catheter-based endovascular procedures
Endovascular procedures provide surgeons and other interventionalists with minimally invasive methods to treat vascular diseases by passing guidewires, catheters, sheaths and treatment devices into the vasculature to and navigate toward a treatment site. The efficiency of this navigation affects patient outcomes, but is frequently compromised by catheter “herniation”, in which the catheter-guidewire system bulges out from the intended endovascular pathway so that the interventionalist can no longer advance it. Here, we showed herniation to be a bifurcation phenomenon that can be predicted and controlled using mechanical characterizations of catheter-guidewire systems and patientspecific clinical imaging. We demonstrated our approach in laboratory models and, retrospectively, in patients who underwent procedures involving transradial neurovascular procedures with an endovascular pathway from the wrist, up in the arm, around the aortic arch, and into the neurovasculature. Our analyses identified a mathematical navigation stability criterion that predicted herniation in all of these settings. Results show that herniation can be predicted through bifurcation analysis, and provide a framework for selecting catheter-guidewire systems to avoid herniation in specific patient anatomy.