Rana Muhammad Armaghan Ayaz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rana Muhammad Armaghan Ayaz has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Yigit Uysalli
Koc University
3 shared publications- Adil Mustafa
School of Biomedical Sciences, University of Bristol, Bristol, UK
2 shared publications - Alper Kiraz
Koc University
2 shared publications - Berna Morova
Istanbul Teknik Üniversitesi
2 shared publications Claudio J. Oton
2 shared publicationsM. Daniyal Ghauri
2 shared publications
Latest Publications
- Open Access
- 10 November 2025
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 57 (12) , 1-12
Symmetrically etched plastic optical fiber sensor for the detection of ethylene glycol contamination in water
Human activities are increasingly contaminating surface and groundwater reserves. Among various pollutants, ethylene glycol (EG) contamination in water is particularly dangerous. At low concentrations it can enter the body undetected and causes serious health problems such as kidney failure and gastrointestinal disorders. This study demonstrates the use of symmetrically etched single-mode plastic optical fiber (POF) sensor model operating at 1550 nm for detecting EG presence in water using COMSOL Multiphysics. The working of the sensor is based on evanescent field interactions with surrounding medium to detect refractive index (RI) changes, while transmission variations through etched POF serving as the sensing metric. Simulations were conducted for aqueous EG solutions ranging from 0 to 0.15 weight fraction, corresponding to RI values ranging between 1.316 and 1.330. The sensor design was optimized by examining the impact of etched cladding diameter and etched length on sensitivity. These parameters were varied from 60 to 7.05 and 1 to 30 μm, respectively. This in turn lead to sensitivity values in the range of 0.39 × 10 −3 to 99.50 × 10 −3 Trans. (A.U)/RIU. Highlighting the importance of evanescent field-surrounding interaction for etched POF sensors, these findings revealed that sensitivity has direct relation with the length of etched region and inverse relation with cladding diameter. The maximum sensitivity of 99.50 × 10 −3 Trans. (A.U)/RIU was achieved with a 30 μm etched length and 7.05 μm cladding diameter. The proposed POF-based sensor demonstrates strong potential for applications in biomedical engineering, biochemical monitoring, and beverage industry offering a compact and sensitive solution for EG contamination detection in water.
- 10 November 2025
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 57 (12) , 1-12
Open AccessSymmetrically etched plastic optical fiber sensor for the detection of ethylene glycol contamination in water
Human activities are increasingly contaminating surface and groundwater reserves. Among various pollutants, ethylene glycol (EG) contamination in water is particularly dangerous. At low concentrations it can enter the body undetected and causes serious health problems such as kidney failure and gastrointestinal disorders. This study demonstrates the use of symmetrically etched single-mode plastic optical fiber (POF) sensor model operating at 1550 nm for detecting EG presence in water using COMSOL Multiphysics. The working of the sensor is based on evanescent field interactions with surrounding medium to detect refractive index (RI) changes, while transmission variations through etched POF serving as the sensing metric. Simulations were conducted for aqueous EG solutions ranging from 0 to 0.15 weight fraction, corresponding to RI values ranging between 1.316 and 1.330. The sensor design was optimized by examining the impact of etched cladding diameter and etched length on sensitivity. These parameters were varied from 60 to 7.05 and 1 to 30 μm, respectively. This in turn lead to sensitivity values in the range of 0.39 × 10 −3 to 99.50 × 10 −3 Trans. (A.U)/RIU. Highlighting the importance of evanescent field-surrounding interaction for etched POF sensors, these findings revealed that sensitivity has direct relation with the length of etched region and inverse relation with cladding diameter. The maximum sensitivity of 99.50 × 10 −3 Trans. (A.U)/RIU was achieved with a 30 μm etched length and 7.05 μm cladding diameter. The proposed POF-based sensor demonstrates strong potential for applications in biomedical engineering, biochemical monitoring, and beverage industry offering a compact and sensitive solution for EG contamination detection in water.
- 7 July 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (14) , 29786-29801
Design and fabrication of short-period long period gratings for refractive index sensing
Fiber optic sensors offer high sensitivity and remote sensing capabilities. This study explores short-period long period gratings (SP-LPGs), fabricated via femtosecond laser, as compact and highly sensitive alternatives to conventional LPGs for refractive index (RI) sensing. Gratings with different periods were modeled and tested using a microfluidic setup. The shortest period (Λ = 13 μm) showed high sensitivity and RI resolution (1.1 × 10−6 RIU), while the longest provided better linearity. An intermediate-period grating (Λ = 14.25 μm) offered optimal performance, demonstrating that period selection allows for tailoring sensitivity and linearity. These results make SP-LPGs promising for applications in medical diagnostics and environmental monitoring.
- 7 July 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (14) , 29786-29801
Design and fabrication of short-period long period gratings for refractive index sensing
Fiber optic sensors offer high sensitivity and remote sensing capabilities. This study explores short-period long period gratings (SP-LPGs), fabricated via femtosecond laser, as compact and highly sensitive alternatives to conventional LPGs for refractive index (RI) sensing. Gratings with different periods were modeled and tested using a microfluidic setup. The shortest period (Λ = 13 μm) showed high sensitivity and RI resolution (1.1 × 10−6 RIU), while the longest provided better linearity. An intermediate-period grating (Λ = 14.25 μm) offered optimal performance, demonstrating that period selection allows for tailoring sensitivity and linearity. These results make SP-LPGs promising for applications in medical diagnostics and environmental monitoring.
- 7 April 2025
- Published by Springer Nature in Sensing and Imaging
- Vol. 26 (1) , 1-20
Tunable Microstructured Silicon Waveguide Based Fabry-Perot Interferometric (Si-FPI) Label-Free Bio-Sensor for Cancer Detection
- 7 April 2025
- Published by Springer Nature in Sensing and Imaging
- Vol. 26 (1) , 1-20
Tunable Microstructured Silicon Waveguide Based Fabry-Perot Interferometric (Si-FPI) Label-Free Bio-Sensor for Cancer Detection
- 14 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1082-1087
Enriching Contact Information Through Fiber Bragg Gratings-Based Exteroception in Soft Bending Actuators
Tactile sensing is of utmost importance for accomplishing fine manipulation tasks and extracting crucial physical features in soft grippers. A contact force estimation and localization approach based on sensing modalities using Fiber Bragg Grating (FBG) transducers and artificial intelligence models are proposed for pneumatically actuated soft fingers. The small packaged sensor unit enables modular design, ease of assembly, and high repeatability with negligible effects on the mechanical performance of the soft finger. The proposed neural networks process the output of the sensing modality and mitigate errors from material nonlinearity, fabrication, and assembly of soft fingers. This, in turn, enhances the accuracy and transferability of force and position estimations, leading to proper metrological indicators. These results provide a step forward in the development of smart soft grippers enabling them to attain “transparent” exteroception. As a result, this work contributes to empowering soft grippers with skillful capabilities to acquire precise tactile information for safe manipulation ranging from agricultural to biomedical fields.
- 14 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1082-1087
Enriching Contact Information Through Fiber Bragg Gratings-Based Exteroception in Soft Bending Actuators
Tactile sensing is of utmost importance for accomplishing fine manipulation tasks and extracting crucial physical features in soft grippers. A contact force estimation and localization approach based on sensing modalities using Fiber Bragg Grating (FBG) transducers and artificial intelligence models are proposed for pneumatically actuated soft fingers. The small packaged sensor unit enables modular design, ease of assembly, and high repeatability with negligible effects on the mechanical performance of the soft finger. The proposed neural networks process the output of the sensing modality and mitigate errors from material nonlinearity, fabrication, and assembly of soft fingers. This, in turn, enhances the accuracy and transferability of force and position estimations, leading to proper metrological indicators. These results provide a step forward in the development of smart soft grippers enabling them to attain “transparent” exteroception. As a result, this work contributes to empowering soft grippers with skillful capabilities to acquire precise tactile information for safe manipulation ranging from agricultural to biomedical fields.
- 5 May 2021
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 38 (6) , 1756-1762
Linear cavity tapered fiber sensor using amplified phase-shift cavity ring-down spectroscopy
Phase-shift cavity ring-down spectroscopy (PS-CRDS) enables the measurement of minute fluctuations in optical loss encountered by an intensity modulated laser beam via lock-in demodulation of the accumulated signal phase as the laser beam propagates through the cavity. A linear fiber cavity containing two highly reflective fiber Bragg gratings (FBGs) and a tapered fiber is a favorable cavity geometry for sensor applications due to its compact nature and wide availability of its components at telecom wavelengths. However, due to the optical absorption of water, usage of telecom wavelengths for sensing of aqueous solutions degrades the sensitivity. This problem can be worked around via an optical amplifier placed inside the fiber cavity, compensating for intrinsic cavity losses. In this work, we demonstrate amplified PS-CRDS using such a linear cavity tapered fiber sensor utilizing an optical amplifier that enables the use of thinner tapered fibers, thus achieving higher sensitivities. We also employ continuous laser wavelength sweeps and analyze peak-to-peak PSs of individual cavity modes instead of using laser-cavity mode locking with the Pound–Drever–Hall technique. This enables further simplification of the experimental arrangement without compromising sensor performance. To test the performance of the reported sensor, solutions of varying sucrose concentrations in deionized water were measured systematically by tracking the average peak-to-peak PS ⟨ ϕ pp ⟩ of the cavity modes. Tapered fibers with waist diameters ( D t a p e r ) around 2.2 µm were used during the experiment and limit of detection (LOD) values were measured down to 2.7 µM, corresponding to 1.01 × 10 − 7 R I U . The reported LOD values can be further improved by mechanical stabilization and thermal control of the device by the use of FBGs with higher reflectivity, by applying automatic optical gain control, and by spectral filtering to remove errors caused by amplified spontaneous emission. The presented concentration sensing device can be suitable for developing compact and highly sensitive, label-free optofluidic sensors.
- 5 May 2021
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 38 (6) , 1756-1762
Linear cavity tapered fiber sensor using amplified phase-shift cavity ring-down spectroscopy
Phase-shift cavity ring-down spectroscopy (PS-CRDS) enables the measurement of minute fluctuations in optical loss encountered by an intensity modulated laser beam via lock-in demodulation of the accumulated signal phase as the laser beam propagates through the cavity. A linear fiber cavity containing two highly reflective fiber Bragg gratings (FBGs) and a tapered fiber is a favorable cavity geometry for sensor applications due to its compact nature and wide availability of its components at telecom wavelengths. However, due to the optical absorption of water, usage of telecom wavelengths for sensing of aqueous solutions degrades the sensitivity. This problem can be worked around via an optical amplifier placed inside the fiber cavity, compensating for intrinsic cavity losses. In this work, we demonstrate amplified PS-CRDS using such a linear cavity tapered fiber sensor utilizing an optical amplifier that enables the use of thinner tapered fibers, thus achieving higher sensitivities. We also employ continuous laser wavelength sweeps and analyze peak-to-peak PSs of individual cavity modes instead of using laser-cavity mode locking with the Pound–Drever–Hall technique. This enables further simplification of the experimental arrangement without compromising sensor performance. To test the performance of the reported sensor, solutions of varying sucrose concentrations in deionized water were measured systematically by tracking the average peak-to-peak PS ⟨ ϕ pp ⟩ of the cavity modes. Tapered fibers with waist diameters ( D t a p e r ) around 2.2 µm were used during the experiment and limit of detection (LOD) values were measured down to 2.7 µM, corresponding to 1.01 × 10 − 7 R I U . The reported LOD values can be further improved by mechanical stabilization and thermal control of the device by the use of FBGs with higher reflectivity, by applying automatic optical gain control, and by spectral filtering to remove errors caused by amplified spontaneous emission. The presented concentration sensing device can be suitable for developing compact and highly sensitive, label-free optofluidic sensors.
- 18 May 2020
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 37 (6) , 1707-1713
Linear cavity tapered fiber sensor using mode-tracking phase-shift cavity ring-down spectroscopy
Phase-shift cavity ring-down spectroscopy (PS-CRDS) is an alternative CRDS approach that allows the detection of minute changes in cavity losses by measurement of the phase shift experienced by a modulated laser as it propagates through a high-quality factor cavity. Fiber loop resonators and microresonators have been employed in previous PS-CRDS demonstrations for liquid phase applications. Here we employ a tapered fiber-based linear fiber cavity for the demonstration of a highly sensitive sensor for sucrose concentration in water using PS-CRDS. Our linear fiber cavity has a small cavity length ( ∼ 1.25 m ) that enables the observation and tracking of individual cavity modes in transmission and phase spectra recorded during laser sweeps. Hence, we eliminate the need for Pound–Drever–Hall locking of the laser source to the cavity resonance and thus provide a simpler experimental scheme. We analyze the recorded data sets to track the changes in phase shifts observed only when the laser wavelength is in resonance with the cavity modes. Such a mode-tracking PS-CRDS approach reveals limit of detection values less than around 400 µM, better than the performance of previously demonstrated PS-CRDS sucrose concentration sensors employing fiber loop resonators. The sensitivity of our sensor critically depends on the fiber taper diameter and can reach up to around 6°/1 mM Suc. for 3.2 µm taper diameter at 6 MHz modulation frequency using fiber Bragg gratings (FBGs) with reflectivities around 86%. This value can be further increased by employing FBGs with higher reflectivities or fiber tapers with smaller diameters provided that the cavity loss due to water absorption is compensated with an amplifier.
- 18 May 2020
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 37 (6) , 1707-1713
Linear cavity tapered fiber sensor using mode-tracking phase-shift cavity ring-down spectroscopy
Phase-shift cavity ring-down spectroscopy (PS-CRDS) is an alternative CRDS approach that allows the detection of minute changes in cavity losses by measurement of the phase shift experienced by a modulated laser as it propagates through a high-quality factor cavity. Fiber loop resonators and microresonators have been employed in previous PS-CRDS demonstrations for liquid phase applications. Here we employ a tapered fiber-based linear fiber cavity for the demonstration of a highly sensitive sensor for sucrose concentration in water using PS-CRDS. Our linear fiber cavity has a small cavity length ( ∼ 1.25 m ) that enables the observation and tracking of individual cavity modes in transmission and phase spectra recorded during laser sweeps. Hence, we eliminate the need for Pound–Drever–Hall locking of the laser source to the cavity resonance and thus provide a simpler experimental scheme. We analyze the recorded data sets to track the changes in phase shifts observed only when the laser wavelength is in resonance with the cavity modes. Such a mode-tracking PS-CRDS approach reveals limit of detection values less than around 400 µM, better than the performance of previously demonstrated PS-CRDS sucrose concentration sensors employing fiber loop resonators. The sensitivity of our sensor critically depends on the fiber taper diameter and can reach up to around 6°/1 mM Suc. for 3.2 µm taper diameter at 6 MHz modulation frequency using fiber Bragg gratings (FBGs) with reflectivities around 86%. This value can be further increased by employing FBGs with higher reflectivities or fiber tapers with smaller diameters provided that the cavity loss due to water absorption is compensated with an amplifier.
- 21 February 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11258, 112580G
Amplified phase shift – fiber cavity ring down spectroscopy for biosensing applications at 1550nm
We present a novel active fiber cavity platform for biosensing applications at 1550nm. We employed the phase shift-cavity ring down spectroscopy to the amplified fiber cavity and demonstrate sensing of sugar solutions with sensitivity and detection limit of 2659o/RIU and 1.11 × 10-5 RIU, respectively.
- 21 February 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11258, 112580G
Amplified phase shift – fiber cavity ring down spectroscopy for biosensing applications at 1550nm
We present a novel active fiber cavity platform for biosensing applications at 1550nm. We employed the phase shift-cavity ring down spectroscopy to the amplified fiber cavity and demonstrate sensing of sugar solutions with sensitivity and detection limit of 2659o/RIU and 1.11 × 10-5 RIU, respectively.