JMJoão Monteiro

João Monteiro

*This is an algorithmically generated author record based on publicly available information.

João Monteiro has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • António Francisco Ambrósio

    Coimbra Institute for Clinical and Biomedical Research (iCBR), Faculty of Medicine, University of Coimbra, 3000-548 Coimbra, Portugal

    1 shared publication
  • Antônio Felipe P. F. Wouk

    Division of Veterinary Ophthalmology, Department of Veterinary Medicine Federal University of Paraná (UFPR) and MeBi Veterinary Hospital Curitiba Paraná Brazil

    1 shared publication
  • Carlos Miguel Marto

    Coimbra Institute for Clinical and Biomedical Research (iCBR) Area of Environment, Genetics and Oncobiology (CIMAGO), Faculty of Medicine, University of Coimbra, 3000-548 Coimbra, Portugal

    1 shared publication
  • Francisco Caramelo

    Laboratory of Biostatistics and Medical Informatics (LBIM), Faculty of Medicine, University of Coimbra, 3000-548 Coimbra, Portugal

    1 shared publication
  • Karla Menezes Cardoso

    University of Coimbra, Coimbra Institute for Clinical and Biomedical Research (iCBR), Area of Environment Genetics and Oncobiology (CIMAGO), and Institute of Biophysics Coimbra Portugal

    1 shared publication
  • Luís Carvalho

    Faculty of Medicine University of Coimbra, Coimbra Institute for Clinical and Biomedical Research (iCBR), area of Environment Genetics and Oncobiology (CIMAGO) and Institute of Biophysics, Faculty of Medicine Coimbra Portugal

    1 shared publication

Latest Publications

  • Open Access

    Comparison of TonoLab , TonoVet Plus, and Tono‐Pen AVIA Vet Tonometers for Measuring Intraocular Pressure in Rats

    by Tarcísio Guerra Guimarães, Antônio Felipe P. F. Wouk, Karla Menezes Cardoso, Francisco Caramelo, Luís Carvalho, João Monteiro, Carlos Miguel Marto, António Francisco Ambrósio, Nuno Alexandre, Maria Filomena Botelho, et al.

    Objectives: To assess the agreement between intraocular pressure (IOP) measurements in rats using different animal‐adapted tonometers and to evaluate the relation among the devices. Methods: IOP was measured using the TonoLab tonometer, followed by the TonoVet Plus and finally, the Tono‐Pen AVIA Vet. A total of 24 eyes were studied from 12 healthy Wistar rats anesthetized with sevoflurane. Agreement analysis was performed between the TonoLab tonometer and the TonoVet Plus, and the TonoLab and Tono‐Pen AVIA Vet using the intraclass correlation coefficient (ICC). For the tested pairs, Bland–Altman graphs were also performed. The relation of TonoVet Plus and Tono‐Pen AVIA Vet tonometers to TonoLab was also evaluated using a simple linear regression. Results: The agreement between the TonoLab tonometers and the TonoVet Plus was weak (ICC = 0.173, 95% CI [−0.129; 0.489], p = 0.130) and not statistically significant. The agreement between the TonoLab and the Tono‐Pen AVIA Vet tonometers was negligible (ICC = 0.011, 95% CI [−0.117; 0.218], p = 0.448). Linear regression analysis between the TonoLab and the TonoVet Plus ( p = 0.256), as well as between the TonoLab and the Tono‐Pen AVIA Vet ( p = 0.897), was not statistically significant. Conclusions: The measurements revealed a consistent pattern in which the Tono‐Pen AVIA Vet showed the highest mean IOP values, followed by the TonoVet Plus and the TonoLab. Knowing the normal values of indirect IOP in rats for each of these tonometers, as well as the differences between them, is fundamental for the proper interpretation of the measurements obtained and for allowing reliable comparisons between the devices.