Arwut Puttarach
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Arwut Puttarach has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Att Phayomhom
Department of Electrical Engineering, Faculty of Engineering, King Mongkut's University of Technology North Bangkok
1 shared publication Somporn Sirisumrannukul
Department of Electrical Engi- neering, Faculty of Engineering, King Mongkut's University of Technology North Bangkok
1 shared publication- Tirapong Kasirawat
Operation Network Department, Provincial Electricity Authority (PEA)
1 shared publication
Latest Publications
- Open Access
- 2 August 2010
- Published by ECTI in ECTI Transactions on Electrical Engineering, Electronics, and Communications
- Vol. 9 (1) , 102-112
Safety Design Planning of Ground Grid for Outdoor Substations in MEA's Power Distribution System
This paper analyzes the performance of a grounding system made of copper conductors and significantly influenced by soil resistivity. The grounding performance is evaluated in terms of ground potential rise (GPR), touch voltage and step voltage caused by a short circuit that generates a flow of large currents in the aboveground structures and grounding system and dissipates in the soil. These currents may cause damage to substation equipment and may be dangerous to personnel working nearby. Safety design planning for step and touch voltages for the existing fault level and future fault levels are extensively investigated for utility applications where personnel hazards may exist. Modelling and simulation is carried out on the Current Distribution Electromagnetic interference Grounding and Soil structure (CDEGS) program. The safety design planning is illustrated by a practical case of ground grid design for the 69/12-24 kV, outdoor-type Bangkrachao substation of Metropolitan Electricity Authority (MEA) with economic analysis. An e®ective solution to improve the performance of the substation grounding is also suggested.
- 2 August 2010
- Published by ECTI in ECTI Transactions on Electrical Engineering, Electronics, and Communications
- Vol. 9 (1) , 102-112
Open AccessSafety Design Planning of Ground Grid for Outdoor Substations in MEA's Power Distribution System
This paper analyzes the performance of a grounding system made of copper conductors and significantly influenced by soil resistivity. The grounding performance is evaluated in terms of ground potential rise (GPR), touch voltage and step voltage caused by a short circuit that generates a flow of large currents in the aboveground structures and grounding system and dissipates in the soil. These currents may cause damage to substation equipment and may be dangerous to personnel working nearby. Safety design planning for step and touch voltages for the existing fault level and future fault levels are extensively investigated for utility applications where personnel hazards may exist. Modelling and simulation is carried out on the Current Distribution Electromagnetic interference Grounding and Soil structure (CDEGS) program. The safety design planning is illustrated by a practical case of ground grid design for the 69/12-24 kV, outdoor-type Bangkrachao substation of Metropolitan Electricity Authority (MEA) with economic analysis. An e®ective solution to improve the performance of the substation grounding is also suggested.