Die Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Die Hu has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Heng Xu
Anhui Jianzhu University, the College of Electronic and Information, Hefei, People’s Republic of China
1 shared publication - Hui Shao
School of Electronic and Information Engineering, Anhui Jianzhu University, Hefei, China
1 shared publication - Juan Chen
Anhui Jianzhu University, the College of Electronic and Information, Hefei, People’s Republic of China
1 shared publication - Long Sun
Anhui Jianzhu University, the College of Electronic and Information, Hefei, People’s Republic of China
1 shared publication
Latest Publications
- 1 January 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (2) , 025214
Non-contact human respiratory and heart signals high precision extraction method based on AFWOA-VMD
Non-contact vital signs detection demonstrates significant potential in fields like fire rescue, intelligent healthcare, and smart homes. However, existing methods encounter challenges in extracting accurate signals in noisy and low signal-to-noise ratio (SNR) indoor scenarios and exhibit heavy reliance on empirical parameter tuning. This study proposes a multi-stage optimized method for extracting heart and respiratory signals from Ultra-wideband (UWB) radar by integrating the autocorrelation function (AF), whale optimization algorithm (WOA), and variational mode decomposition (VMD). First, direct current (DC) removal, singular value decomposition (SVD), and Butterworth filtering are applied to suppress noise and eliminate baseline drift. Then, autocorrelation analysis of the slow-time radar signal is used to leverage the periodicity of vital signs for accurate target distance detection, improving signal extraction accuracy. Finally, WOA dynamically optimizes VMD parameters to adapt to time-varying signals, enhance mode separation and noise resistance, and screen effective components based on modal energy contribution. Vital signs frequencies are subsequently extracted using Fast Fourier transform (FFT). Experiments using 180 datasets from three volunteers at four distances (0.8 m–2.4 m) show that the proposed method achieves average errors of 4.84% in distance, 2.52% in respiratory rate (RR) and 3.54% in heart rate (HR) under static indoor line-of-sight conditions. These results indicate that the method proposed in this paper can provide accurate and relatively stable non-contact vital signs estimation within the test distance range.
- 1 January 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (2) , 025214
Non-contact human respiratory and heart signals high precision extraction method based on AFWOA-VMD
Non-contact vital signs detection demonstrates significant potential in fields like fire rescue, intelligent healthcare, and smart homes. However, existing methods encounter challenges in extracting accurate signals in noisy and low signal-to-noise ratio (SNR) indoor scenarios and exhibit heavy reliance on empirical parameter tuning. This study proposes a multi-stage optimized method for extracting heart and respiratory signals from Ultra-wideband (UWB) radar by integrating the autocorrelation function (AF), whale optimization algorithm (WOA), and variational mode decomposition (VMD). First, direct current (DC) removal, singular value decomposition (SVD), and Butterworth filtering are applied to suppress noise and eliminate baseline drift. Then, autocorrelation analysis of the slow-time radar signal is used to leverage the periodicity of vital signs for accurate target distance detection, improving signal extraction accuracy. Finally, WOA dynamically optimizes VMD parameters to adapt to time-varying signals, enhance mode separation and noise resistance, and screen effective components based on modal energy contribution. Vital signs frequencies are subsequently extracted using Fast Fourier transform (FFT). Experiments using 180 datasets from three volunteers at four distances (0.8 m–2.4 m) show that the proposed method achieves average errors of 4.84% in distance, 2.52% in respiratory rate (RR) and 3.54% in heart rate (HR) under static indoor line-of-sight conditions. These results indicate that the method proposed in this paper can provide accurate and relatively stable non-contact vital signs estimation within the test distance range.