VBViktor Boichun

Viktor Boichun

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Viktor Boichun has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparative analysis of the accuracy of neural network and analytical methods in modelling fatigue fracture of titanium alloy

    by Iryna Didych, Oleh Yasniy, Dmytro Tymoshchuk, Oleksandr Holotenko, Viktor Boichun

    Fatigue crack growth rate is modelled by neural network and compared with analytical models, namely, the Paris' law and polynomial log regressions of the second to fifth degree. To assess the accuracy of the modelling, the determination coefficient R², mean absolute error (MAE) and mean absolute percentage error (MAPE) are used to assess the accuracy of the modelling. Results show that both approaches, in particular, the classical analytical models and the neural network, provide the high accuracy of approximation of the experimental data. At the same time, the neural network demonstrates an advantage in the region of high values of DK, where a nonlinear acceleration of crack growth is observed, reaching a coefficient of determination R² equal to 0.9994. The presented approach confirms the effectiveness of applying machine learning methods, in particular neural networks, in the problems of fracture mechanics and fatigue analysis.

  • Open Access

    ДОСЛІДЖЕННЯ ВПЛИВУ РІВНЯ ГІСТЕРЕЗИСУ НА ТЕМПЕРАТУРНИЙ КОМФОРТ ПРИМІЩЕННЯ ТА ЕНЕРГОСПОЖИВАННЯ АВТОМАТИЗОВАНОЇ СИСТЕМИ КЕРУВАННЯ МІКРОКЛІМАТОМ

    by Юрій Микитів, Ігор Чихіра, Ігор Поливаний, Віктор Бойчун

    This article presents the results of the development, implementation, and in-depth investigation of a mathematical model for an automated room temperature control system that utilizes a Hydronic Underfloor Heating (HUH) unit operating under a hysteresis-based control principle. The model was implemented within the Python environment, employing numerical methods to ensure high accuracy in dynamic simulation. Key physical factors rigorously accounted for in the model include: detailed thermophysical properties of the room structure and air mass; heat losses through enclosing structures (walls, windows); the significant thermal inertia of the massive concrete heating floor slab; and the time-varying influence of outdoor temperature as the primary disturbance factor. The central objective of the investigation was to quantify the impact of the hysteresis bandwidth on key system performance indicators: energy consumption, frequency of actuator cycling, and the resulting level of thermal comfort. The simulation experiment was conducted over a continuous period of 30 calendar days for each scenario, encompassing typical and distinct seasonal conditions: winter, spring, summer, and autumn. The hysteresis width was systematically varied from a minimal, narrow band of $0.1 \text{ °C}$ up to $5.0 \text{ °C}$ in precise increments of $0.1 \text{ °C}$. This comprehensive sweep allowed for the construction of complete relationships between the control parameter and the system's dynamic response. The obtained simulation results clearly demonstrated a critical trade-off: increasing the hysteresis width significantly reduces the number of heater activations, thereby potentially extending the lifespan of the actuator mechanisms. However, this action concurrently leads to an increase in the total operational time of the system and, consequently, a higher overall energy consumption due to less precise regulation. It was established that excessively wide hysteresis bands (e.g., beyond $1.0 \text{ °C}$ for most seasons) cause significant indoor temperature fluctuations that exceed acceptable limits, leading to a sharp reduction in occupant thermal comfort. Based on the detailed analysis, optimal hysteresis ranges were empirically determined for varying climatic conditions, providing the best achievable balance between energy conservation and the maintenance of a stable microclimate: For winter conditions (high heat loss): $0.6–0.8 \text{ °C}$. This value effectively compensates for the high thermal inertia of the floor while limiting temperature drift. For spring and autumn (shoulder season) conditions (moderate heat loss): $0.4–0.5 \text{ °C}$. A narrower band is required here for faster response to external disturbances and reduced energy overshoot. The developed mathematical model is a powerful and flexible tool. It can be utilized not only for tuning and optimizing control parameters (such as hysteresis width) of automated microclimate systems but also for predicting and evaluating their energy efficiency under various climatic scenarios during the preliminary design phase. У статті представлено результати розроблення та дослідження математичної моделі автоматизованої системи регулювання температури приміщення з теплою водяною підлогою, що працює за гістерезисним принципом керування. Модель реалізована в середовищі Python і враховує теплофізичні властивості приміщення, теплові втрати через огороджувальні конструкції, інерційність нагрівальної підлоги та вплив зовнішньої температури. Симуляцію проведено для 30 діб у різні сезонні періоди — зимовий, весняний, літній та осінній — при різних рівнях гістерезису від 0.1 до 5 °C з кроком 0.1 °C. Отримані результати показали, що збільшення гістерезису призводить до зменшення кількості ввімкнень нагрівача, проте збільшує тривалість його роботи та загальне енергоспоживання. Надмірне розширення гістерезису спричиняє значні коливання температури в приміщенні та зниження комфорту температурного режиму. Визначено оптимальні діапазони гістерезису для досліджуваного приміщення при різних сезонних умов: 0.6–0.8 °C для зимового періоду та 0.4–0.5 °C для весняно-осінніх. Такі значення забезпечують найкращий баланс між енергозбереженням і комфортом температури. Розроблена модель може бути використана як інструмент для налаштування параметрів автоматизованих систем керування мікрокліматом і оцінювання їх енергоефективності за різних кліматичних умов.