Ruipeng Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ruipeng Xu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Xueren Li
School of Safety Engineering, China University of Mining and Technology 1 , Xuzhou 221116
2 shared publications - Bichen Shang1 shared publication
- J. Ruud van Ommen
Department of Chemical Engineering, Delft University of Technology, Van der Maasweg 9, Delft 2629 HZ, the Netherlands
1 shared publication Jiaqi Fan
1 shared publication- Jiaqi Fan
School of Safety Engineering, China University of Mining and Technology 1 , Xuzhou 221116
1 shared publication Jie Li
School of Safety Engineering, China University of Mining and Technology 1 , Xuzhou 221116
1 shared publication
Latest Publications
- 1 June 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (6)
Effects of mask leakage characteristics on aerosol inhalability and deposition in the human nasal cavity
Frequent emergence of infectious respiratory diseases has highlighted the importance of effective respiratory protection against airborne particle exposure. However, imperfect mask fitting often leads to leakage at the mask–face interface, which significantly influence aerosol inhalability and deposition in the human airway. In this study, a coupled numerical model including the breathing zone, face mask, facial interface, and nasal cavity was developed. The model was used to investigate airflow leakage and the subsequent transport and deposition behavior of inhalable aerosols. Representative leakage scenarios were simulated to evaluate effects of leakage location, breathing intensity, and leakage area on particle transport behavior. Results show that leakage location strongly affects airflow organization and particle transport. Midline leakage produced symmetric flow and deposition in the nasal cavities, while cheek leakage induced pronounced asymmetric deposition. Even with leakage, mask wearing still reduces particle penetration into the deeper respiratory tract. Compared with the no-mask condition, particle penetration decreases by an average of 7.36%, with the largest reduction (13.8%) observed under chin leakage. Increasing breathing intensity enhanced particle inertia and promoted inertial impaction in the upstream nasal regions. As the inhalation rate increased to 60 l/min, the overall nasal deposition efficiency reached 90.6%. In contrast, leakage area mainly redistributed particle deposition locations within the nasal cavity while exerting a limited influence on overall deposition–penetration balance. The findings provided insights into aerosol inhalation exposure under mask leakage conditions. It aimed to improving respirator design and respiratory protection strategies.
- 1 June 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (6)
Effects of mask leakage characteristics on aerosol inhalability and deposition in the human nasal cavity
Frequent emergence of infectious respiratory diseases has highlighted the importance of effective respiratory protection against airborne particle exposure. However, imperfect mask fitting often leads to leakage at the mask–face interface, which significantly influence aerosol inhalability and deposition in the human airway. In this study, a coupled numerical model including the breathing zone, face mask, facial interface, and nasal cavity was developed. The model was used to investigate airflow leakage and the subsequent transport and deposition behavior of inhalable aerosols. Representative leakage scenarios were simulated to evaluate effects of leakage location, breathing intensity, and leakage area on particle transport behavior. Results show that leakage location strongly affects airflow organization and particle transport. Midline leakage produced symmetric flow and deposition in the nasal cavities, while cheek leakage induced pronounced asymmetric deposition. Even with leakage, mask wearing still reduces particle penetration into the deeper respiratory tract. Compared with the no-mask condition, particle penetration decreases by an average of 7.36%, with the largest reduction (13.8%) observed under chin leakage. Increasing breathing intensity enhanced particle inertia and promoted inertial impaction in the upstream nasal regions. As the inhalation rate increased to 60 l/min, the overall nasal deposition efficiency reached 90.6%. In contrast, leakage area mainly redistributed particle deposition locations within the nasal cavity while exerting a limited influence on overall deposition–penetration balance. The findings provided insights into aerosol inhalation exposure under mask leakage conditions. It aimed to improving respirator design and respiratory protection strategies.
- Open Access
- 20 May 2026
- Published by Elsevier in Powder Technology
- Vol. 481
Computational optimization of spatial drug release to enhance inhaled particle deposition in human upper and central airways
- 20 May 2026
- Published by Elsevier in Powder Technology
- Vol. 481
Open AccessComputational optimization of spatial drug release to enhance inhaled particle deposition in human upper and central airways
- Open Access
- 5 January 2026
- Published by Elsevier in Energy and Buildings
- Vol. 354
Cross-domain indoor performance prediction via in-context learning: A CFD-TabPFN-SHAP framework integrating air quality, energy, and thermal comfort
- 5 January 2026
- Published by Elsevier in Energy and Buildings
- Vol. 354
Open AccessCross-domain indoor performance prediction via in-context learning: A CFD-TabPFN-SHAP framework integrating air quality, energy, and thermal comfort