Ashwin Durairaj
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ashwin Durairaj has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Johanna Feary
National Heart and Lung Institute, Imperial College London, London, UK
2 shared publications Maia Lesosky
Imperial College London National Heart and Lung Institute, London, UK
2 shared publications- Patrick Howlett
National Heart and Lung Institute, Imperial College London, London, UK
2 shared publications Jeffrey Gan
Imperial College London Faculty of Medicine, London, UK
1 shared publication
Latest Publications
- Open Access
- 9 July 2026
- Published by BMJ in Occupational and Environmental Medicine
- Vol. 83 (5) , 287-290
Adjusting for the diagnostic accuracy of CXR in the dose-response relationship between cumulative silica exposure and silicosis in miners
Introduction: A recent meta-analysis confirmed that chest X-ray (CXR) has low sensitivity for diagnosing silicosis. We re-estimated previously published dose-response relationships between cumulative respirable crystalline silica (RCS) exposure and silicosis risk, under the assumptions that sensitivity was either fixed or relative to the population proportion of severe silicosis. Methods: We combined unpublished logistic regression models from Scottish coal miners with meta-analysis results to model how CXR sensitivity changed according to cumulative RCS exposure. We assumed specificity was 0.95. Among mining cohorts, we calculated the difference in the cumulative risk of silicosis between the unadjusted and fixed and relative scenarios. Finally, we re-estimated a published dose-response meta-analysis and associated absolute risk reductions (ARR). Results: The cumulative risk of silicosis was substantially higher in both the fixed and relative sensitivity scenarios compared with the unadjusted estimate in all mining cohorts. This was most pronounced in the relative scenario and when cumulative RCS exposures were below approximately 6 mg/m³-years. A reduction in cumulative RCS exposure from 4 to 2mg/m³-years corresponded to larger ARRs in the fixed and relative scenarios than the unadjusted scenario; 382 (95% CI 361 to 399) and 529 (95% CI 353 to 592) cases per 1000 miners compared with 313 (95% CI 288 to 333) cases per 1000 miners, respectively. Discussion: We relied on a single estimate of the proportion of severe disease to link sensitivity and cumulative RCS exposure. Nevertheless, adjusting for the reduced diagnostic accuracy of CXR for silicosis suggests the burden of silicosis is underestimated in published mining cohorts.
- 9 July 2026
- Published by BMJ in Occupational and Environmental Medicine
- Vol. 83 (5) , 287-290
Open AccessAdjusting for the diagnostic accuracy of CXR in the dose-response relationship between cumulative silica exposure and silicosis in miners
Introduction: A recent meta-analysis confirmed that chest X-ray (CXR) has low sensitivity for diagnosing silicosis. We re-estimated previously published dose-response relationships between cumulative respirable crystalline silica (RCS) exposure and silicosis risk, under the assumptions that sensitivity was either fixed or relative to the population proportion of severe silicosis. Methods: We combined unpublished logistic regression models from Scottish coal miners with meta-analysis results to model how CXR sensitivity changed according to cumulative RCS exposure. We assumed specificity was 0.95. Among mining cohorts, we calculated the difference in the cumulative risk of silicosis between the unadjusted and fixed and relative scenarios. Finally, we re-estimated a published dose-response meta-analysis and associated absolute risk reductions (ARR). Results: The cumulative risk of silicosis was substantially higher in both the fixed and relative sensitivity scenarios compared with the unadjusted estimate in all mining cohorts. This was most pronounced in the relative scenario and when cumulative RCS exposures were below approximately 6 mg/m³-years. A reduction in cumulative RCS exposure from 4 to 2mg/m³-years corresponded to larger ARRs in the fixed and relative scenarios than the unadjusted scenario; 382 (95% CI 361 to 399) and 529 (95% CI 353 to 592) cases per 1000 miners compared with 313 (95% CI 288 to 333) cases per 1000 miners, respectively. Discussion: We relied on a single estimate of the proportion of severe disease to link sensitivity and cumulative RCS exposure. Nevertheless, adjusting for the reduced diagnostic accuracy of CXR for silicosis suggests the burden of silicosis is underestimated in published mining cohorts.
- Open Access
- 1 December 2025
- Published by BMJ in Occupational and Environmental Medicine
- Vol. 82 (12) , 614-620
Diagnostic accuracy of chest X-ray screening for silicosis: a systematic review, meta-analysis and modelling study
Chest X-ray (CXR) is widely used for silicosis diagnosis, despite concerns regarding sensitivity. We investigated the diagnostic accuracy of CXR for silicosis screening compared with CT, high-resolution CT (HRCT) and autopsy, and modelled the relationship between CXR sensitivity and disease severity. Medline, Embase, Scopus and Web of Science databases were searched on 2 July 2024 (PROSPERO registration: CRD42024513830). Meta-analyses were performed by reference standard and at increasing reference test severity cut-offs. The Quality Assessment of Diagnostic Accuracy Studies-2 tool assessed risk of bias. In scenarios of fixed and relative sensitivity, according to disease severity, we estimated missed silicosis cases and the number needed to screen (NNS) in hypothetical populations of low (5%), medium (15%) and high (30%) silicosis prevalence. Twenty studies included 2156 participants and 1105 silicosis cases. CXR had moderate sensitivity (0.76; 95% CI 0.63 to 0.86, I 2 =84%) and high specificity (0.89, 95% CI 0.77 to 0.95, I 2 =57%) compared with HRCT in 12 studies, and low sensitivity (0.50, 95% CI 0.45 to 0.55, I 2 =0%) and high specificity (0.91, 95% CI 0.87 to 0.93, I 2 =20%) compared with autopsy in two studies. CXR sensitivity increased with higher reference test severity cut-offs. Clinically relevant numbers of cases were missed in fixed and relative sensitivity scenarios; increased prevalence and less severe disease resulted in more missed cases and a lower NNS. Silicosis severity and reference test type both plausibly influence CXR sensitivity. Assuming either fixed or relative sensitivity results in missed silicosis cases. Judicious HRCT screening is likely to improve case detection.
- 1 December 2025
- Published by BMJ in Occupational and Environmental Medicine
- Vol. 82 (12) , 614-620
Open AccessDiagnostic accuracy of chest X-ray screening for silicosis: a systematic review, meta-analysis and modelling study
Chest X-ray (CXR) is widely used for silicosis diagnosis, despite concerns regarding sensitivity. We investigated the diagnostic accuracy of CXR for silicosis screening compared with CT, high-resolution CT (HRCT) and autopsy, and modelled the relationship between CXR sensitivity and disease severity. Medline, Embase, Scopus and Web of Science databases were searched on 2 July 2024 (PROSPERO registration: CRD42024513830). Meta-analyses were performed by reference standard and at increasing reference test severity cut-offs. The Quality Assessment of Diagnostic Accuracy Studies-2 tool assessed risk of bias. In scenarios of fixed and relative sensitivity, according to disease severity, we estimated missed silicosis cases and the number needed to screen (NNS) in hypothetical populations of low (5%), medium (15%) and high (30%) silicosis prevalence. Twenty studies included 2156 participants and 1105 silicosis cases. CXR had moderate sensitivity (0.76; 95% CI 0.63 to 0.86, I 2 =84%) and high specificity (0.89, 95% CI 0.77 to 0.95, I 2 =57%) compared with HRCT in 12 studies, and low sensitivity (0.50, 95% CI 0.45 to 0.55, I 2 =0%) and high specificity (0.91, 95% CI 0.87 to 0.93, I 2 =20%) compared with autopsy in two studies. CXR sensitivity increased with higher reference test severity cut-offs. Clinically relevant numbers of cases were missed in fixed and relative sensitivity scenarios; increased prevalence and less severe disease resulted in more missed cases and a lower NNS. Silicosis severity and reference test type both plausibly influence CXR sensitivity. Assuming either fixed or relative sensitivity results in missed silicosis cases. Judicious HRCT screening is likely to improve case detection.