Zhongze Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhongze Li has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Feng Liu
Tsinghua University
4 shared publications - Xiaoyu Peng
Tsinghua University
4 shared publications - Zhaojian Wang
Shanghai Jiao Tong University
3 shared publications Cong Fu
Power Dispatching Control Center, Guangdong Power Grid Company Ltd., Guangzhou, China
2 shared publications- Xi Ru
Department of Electrical Engineering, State Key Laboratory of Power System Operation and Control, Tsinghua University, Beijing, China
2 shared publications Jianxin Zhang
China Southern Power Grid
1 shared publication
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (6) , 4871-4874
Relative-Degree Wall Restricts Passivity-Based Stability Analysis in Inverter-Dominant Grids
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (6) , 4871-4874
Relative-Degree Wall Restricts Passivity-Based Stability Analysis in Inverter-Dominant Grids
- 23 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 23 (15455955) , 6915-6928
Stability Degradation Induced by Angle–Voltage Coupling in Power Systems: Bode-Type Fundamental Performance Limitation Analysis
This paper presents a novel perspective on understanding how the interaction between phase-angle and voltage dynamics affects the stability of inverter-dominated power systems. To explore this, we analyze Bode’s integral of frequency-domain sensitivity functions, which reveals the underlying law that limits the system’s ability to reject disturbances. Our finding indicates that, although the “total” sensitivity integrals remain conservative in angle-voltage coupled systems, the coupling reshapes their distribution between phase-angle and voltage dynamics, potentially worsening system stability. This finding is generalized into fundamental laws named sensitivity conservation and its breaking in this paper. In addition to the mechanism, our work also suggests that the stability could be improved by appropriately redistributing sensitivity across different frequency bands, diverse devices, or between phase-angle and voltage dynamics. However, this redistribution must be conducted carefully, as the sensitivity breaking law indicates that improving the performance of one aspect may lead to instability of another. This law cannot be bypassed directly by any controllers with a generic feedback structure, underscoring the fundamental limit of angle-voltage coupling dynamics and fostering a broader understanding of its nature. The proposed mechanism provides a core principle for control design in angle-voltage coupled power systems.
- 23 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 23 (15455955) , 6915-6928
Stability Degradation Induced by Angle–Voltage Coupling in Power Systems: Bode-Type Fundamental Performance Limitation Analysis
This paper presents a novel perspective on understanding how the interaction between phase-angle and voltage dynamics affects the stability of inverter-dominated power systems. To explore this, we analyze Bode’s integral of frequency-domain sensitivity functions, which reveals the underlying law that limits the system’s ability to reject disturbances. Our finding indicates that, although the “total” sensitivity integrals remain conservative in angle-voltage coupled systems, the coupling reshapes their distribution between phase-angle and voltage dynamics, potentially worsening system stability. This finding is generalized into fundamental laws named sensitivity conservation and its breaking in this paper. In addition to the mechanism, our work also suggests that the stability could be improved by appropriately redistributing sensitivity across different frequency bands, diverse devices, or between phase-angle and voltage dynamics. However, this redistribution must be conducted carefully, as the sensitivity breaking law indicates that improving the performance of one aspect may lead to instability of another. This law cannot be bypassed directly by any controllers with a generic feedback structure, underscoring the fundamental limit of angle-voltage coupling dynamics and fostering a broader understanding of its nature. The proposed mechanism provides a core principle for control design in angle-voltage coupled power systems.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (3) , 2398-2401
Compositional Grid Codes With Guarantee on Both Stability and Dynamic Performance
This paper proposes a compositional grid code framework that guarantees power system stability and dynamic performance simultaneously. By reformulating device-grid interactions based on passivity theory, we derive compositional stability indices compatible with heterogeneous dynamics. Then, the proposed grid codes decompose system-level stability certificates into quantitative constraints upon individual devices while accommodating standard dynamic specifications. Compared with existing approaches, this method overcomes the previous limitations in closed-loop stability assurance and facilitates the plug-and-play integration of heterogeneous dynamic devices.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (3) , 2398-2401
Compositional Grid Codes With Guarantee on Both Stability and Dynamic Performance
This paper proposes a compositional grid code framework that guarantees power system stability and dynamic performance simultaneously. By reformulating device-grid interactions based on passivity theory, we derive compositional stability indices compatible with heterogeneous dynamics. Then, the proposed grid codes decompose system-level stability certificates into quantitative constraints upon individual devices while accommodating standard dynamic specifications. Compared with existing approaches, this method overcomes the previous limitations in closed-loop stability assurance and facilitates the plug-and-play integration of heterogeneous dynamic devices.