GHGaoyu Han

Gaoyu Han

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gaoyu Han has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Haotian Zhou

    School of Mechanical and Electronic Engineering, Wuhan University of Technology, Wuhan, China

    2 shared publications
  • Tianliang Li

    School of Mechanical and Electrical Engineering, Wuhan University of Technology, Wuhan, China

    2 shared publications
  • Aohui Li

    School of Mechanical and Electrical Engineering, Wuhan University of Technology, Wuhan 430070, People’s Republic of China

    1 shared publication
  • Aohui Li

    School of Mechanical and Electronic Engineering, Wuhan University of Technology, Wuhan, China

    1 shared publication
  • Bin Wu

    State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, China

    1 shared publication
  • Jian Zhang

    School of Mechanical and Electrical Engineering, Wuhan University of Technology, Wuhan 430070, People’s Republic of China

    1 shared publication

Latest Publications

  • Pressure Sensitivity Monitoring in Fabrication of Miniaturized All-Fiber-Tip Sensor for Turbine Blade Dynamic Pressure Measurement

    by Tianliang Li, Gaoyu Han, Jian Zhang, Aohui Li, Zhou Haotian

    Different engines exhibit distinct pressure measurement requirements, particularly in the context of dynamic pressure monitoring on turbine blades, where the customization of sensitivity is critical to ensuring optimal performance and maintaining structural safety. This study introduces a miniaturized all-fiber-tip pressure sensor featuring a diaphragm structure based on Fabry–Perot (F-P) interference, which facilitates the precise measurement of dynamic pressure on the suction surface of turbine blades. Furthermore, a sensitivity enhancement method based on etching is presented, accompanied by a custom algorithm to monitor dynamic changes in the sensor’s sensitivity throughout the etching process. The verification process encompassed both the mechanical and optical characteristics of the all-fiber-tip pressure sensor, yielding relative errors of 3.63%, 1.44%, 1.26%, and 1.76%, respectively, when comparing the monitoring results to the pressure calibration values. Regarding the sensitivity at light intensity extrema, the Root Mean Square Error (RMSE) was measured at 0.2571, thereby validating the accuracy of the proposed monitoring algorithm. Experimental validation demonstrates the sensor’s exceptional performance: its sensitivity reaches -359 pm/kPa, with the maximum full-scale error being a mere 0.69%. During the dynamic pressure monitoring of the turbine blade suction surface, the measured pressure amplitude fluctuates within ±300 Pa(<1.38 kPa). Additionally, fast Fourier transform (FFT) analysis reveals pulsation frequencies ranging from 0.7471 to 4.439 Hz, providing critical insights for blade structural resonance research and optimization in design.

  • Wavelength–Phase Hybrid Coding Optical Fiber Medical Monitor With Intracranial Pressure and Temperature Dynamic Self-Decoupling

    by Jian Zhang, Haotian Zhou, Aohui Li, Gaoyu Han, Zhengkai Zhu, Jiehu Kang, Bin Wu, Jun Wang, Tianliang Li

    The simultaneous monitoring of intracranial pressure (ICP) and intracranial temperature (ICT) are essential processes for assessing neurocritical conditions and preventing secondary brain injury. This study develops a medical monitor employing the optical fiber sensing technique, with a wavelength-phase hybrid coding approach, to simultaneously measure pressure and temperature. The optical fiber sensor is configured with a Fabry-Pérot (F-P) cavity and a fiber Bragg grating (FBG). The F-P cavity is fabricated through precision cutting and polishing, showing the advantages of controllable performance and low cost. Aiming at the multi-feature spectrum demodulation, this work combined the discrete Fourier transform with a centroid peak-detection technique to propose a wavelength-phase calculation strategy. Experimentally measuring range of the designed monitor is -300~300mmHg with a sensitivity of 248.67pm/mmHg. The error of pressure was reduced to a lower level of 2.48% by using temperature compensation. Additionally, the study constructed ex vivo tissue and in vivo animal experiments designed to test the monitor's performance. The results show that the monitor can accurately measure ICP and brain temperature, and it exhibits rapid response characteristics compared to commercial monitors. Such merits show the great potential of the monitor in the diagnosis and surveillance of neurocritical care patients.