Soyeon Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Soyeon Lee has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Yingfu Li
Department of Biochemistry and Biomedical Sciences McMaster University Hamilton Ontario Canada
6 shared publications - Amal Mathai
Department of Biochemistry and Biomedical Sciences McMaster University Hamilton Ontario Canada
2 shared publications Bruno J. Salena
Department of Medicine McMaster University Hamilton Ontario Canada
2 shared publications- Connor Nurmi
Department of Biochemistry and Biomedical Sciences McMaster University Hamilton Ontario Canada
2 shared publications Jimmy Gu
Department of Biochemistry and Biomedical Sciences McMaster University Hamilton Ontario Canada
2 shared publicationsLetizia Dondi
School of Biomedical Engineering McMaster University Hamilton Ontario Canada
2 shared publications
Latest Publications
- Open Access
- 10 October 2026
- Published by Wiley in Angewandte Chemie
Stabilizing Functional Nucleic Acids for Real‐Sample Diagnostics
Functional nucleic acids (FNAs), including aptamers and DNAzymes, offer programmable recognition and catalysis for biosensing, but their performance in real samples is often compromised by nuclease degradation, matrix effects, and interface‐associated losses. For diagnostic translation, stability must, therefore, be defined not only as strand persistence, but as retained folding, binding, catalysis, and signal generation under assay‐relevant conditions. This review examines strategies for stabilizing FNAs in complex biological matrices and organizes the field around four design levers: Chemical, topological, architectural, and microenvironment/interface engineering. Chemical modification of sugars, backbones, and bases can reduce nuclease susceptibility, but requires functional validation. Topological approaches, including terminus shielding, circularization, covalent locking, and mechanically interlocked structures, limit strand accessibility, and reinforce functional conformations. Architectural strategies use multivalency, scaffolded presentation, DNA nanostructures, and rolling circle amplification‐derived concatemers to improve robustness and signal retention. Microenvironment engineering further stabilizes FNAs through controlled immobilization, antifouling interfaces, nanomaterial‐assisted protection, hydrogel or microgel confinement, and sample processing. Case studies in saliva, serum, urine, and stool illustrate how these levers can be combined to enable reliable FNA‐based real‐sample diagnostics.
- 10 October 2026
- Published by Wiley in Angewandte Chemie
Open AccessStabilizing Functional Nucleic Acids for Real‐Sample Diagnostics
Functional nucleic acids (FNAs), including aptamers and DNAzymes, offer programmable recognition and catalysis for biosensing, but their performance in real samples is often compromised by nuclease degradation, matrix effects, and interface‐associated losses. For diagnostic translation, stability must, therefore, be defined not only as strand persistence, but as retained folding, binding, catalysis, and signal generation under assay‐relevant conditions. This review examines strategies for stabilizing FNAs in complex biological matrices and organizes the field around four design levers: Chemical, topological, architectural, and microenvironment/interface engineering. Chemical modification of sugars, backbones, and bases can reduce nuclease susceptibility, but requires functional validation. Topological approaches, including terminus shielding, circularization, covalent locking, and mechanically interlocked structures, limit strand accessibility, and reinforce functional conformations. Architectural strategies use multivalency, scaffolded presentation, DNA nanostructures, and rolling circle amplification‐derived concatemers to improve robustness and signal retention. Microenvironment engineering further stabilizes FNAs through controlled immobilization, antifouling interfaces, nanomaterial‐assisted protection, hydrogel or microgel confinement, and sample processing. Case studies in saliva, serum, urine, and stool illustrate how these levers can be combined to enable reliable FNA‐based real‐sample diagnostics.
- Open Access
- 10 October 2026
- Published by Wiley in Angewandte Chemie International Edition
- p. e1386648
Stabilizing Functional Nucleic Acids for Real‐Sample Diagnostics
Functional nucleic acids (FNAs), including aptamers and DNAzymes, offer programmable recognition and catalysis for biosensing, but their performance in real samples is often compromised by nuclease degradation, matrix effects, and interface‐associated losses. For diagnostic translation, stability must, therefore, be defined not only as strand persistence, but as retained folding, binding, catalysis, and signal generation under assay‐relevant conditions. This review examines strategies for stabilizing FNAs in complex biological matrices and organizes the field around four design levers: Chemical, topological, architectural, and microenvironment/interface engineering. Chemical modification of sugars, backbones, and bases can reduce nuclease susceptibility, but requires functional validation. Topological approaches, including terminus shielding, circularization, covalent locking, and mechanically interlocked structures, limit strand accessibility, and reinforce functional conformations. Architectural strategies use multivalency, scaffolded presentation, DNA nanostructures, and rolling circle amplification‐derived concatemers to improve robustness and signal retention. Microenvironment engineering further stabilizes FNAs through controlled immobilization, antifouling interfaces, nanomaterial‐assisted protection, hydrogel or microgel confinement, and sample processing. Case studies in saliva, serum, urine, and stool illustrate how these levers can be combined to enable reliable FNA‐based real‐sample diagnostics.
- 10 October 2026
- Published by Wiley in Angewandte Chemie International Edition
- p. e1386648
Open AccessStabilizing Functional Nucleic Acids for Real‐Sample Diagnostics
Functional nucleic acids (FNAs), including aptamers and DNAzymes, offer programmable recognition and catalysis for biosensing, but their performance in real samples is often compromised by nuclease degradation, matrix effects, and interface‐associated losses. For diagnostic translation, stability must, therefore, be defined not only as strand persistence, but as retained folding, binding, catalysis, and signal generation under assay‐relevant conditions. This review examines strategies for stabilizing FNAs in complex biological matrices and organizes the field around four design levers: Chemical, topological, architectural, and microenvironment/interface engineering. Chemical modification of sugars, backbones, and bases can reduce nuclease susceptibility, but requires functional validation. Topological approaches, including terminus shielding, circularization, covalent locking, and mechanically interlocked structures, limit strand accessibility, and reinforce functional conformations. Architectural strategies use multivalency, scaffolded presentation, DNA nanostructures, and rolling circle amplification‐derived concatemers to improve robustness and signal retention. Microenvironment engineering further stabilizes FNAs through controlled immobilization, antifouling interfaces, nanomaterial‐assisted protection, hydrogel or microgel confinement, and sample processing. Case studies in saliva, serum, urine, and stool illustrate how these levers can be combined to enable reliable FNA‐based real‐sample diagnostics.
- Open Access
- 5 September 2026
- Published by Wiley in Advanced Materials
- Vol. 38 (56)
Lab‐in‐a‐Tube System Integrating Hierarchically Wrinkled Electrodes and DNAzyme‐Functionalized Beads for Diagnosis of Clostridioides difficile Infection
The diagnosis of bacterial infections remains slow because many existing methods rely on enrichment steps such as nucleic acid amplification or growth culture. RNA‐cleaving DNAzymes offer a promising route to accelerate bacterial diagnosis because they can be selected and programmed to specifically recognize disease‐causing bacteria and generate reporter DNA strands for signal readout. However, integrating DNAzymes into biosensors capable of analyzing complex biological matrices remains challenging, as matrix‐associated interferents can destabilize DNAzymes, suppress catalytic activity, and compromise signal detection. Here, we integrate redox RNA‐cleaving DNAzymes housed on antifouling magnetic beads with a lab‐in‐a‐tube platform that incorporates hierarchically structured sensing electrodes within a tubular flow cell for enrichment‐free detection of Clostridioides difficile in stool samples. The combination of antifouling magnetic beads and fluidic replenishment of DNA reporters across the hierarchical electrodes reduces nonspecific binding and enhances reporter capture efficiency, achieving a limit of detection as low as 1.3 × 10 2 CFU mL −1 in buffer. Using an optimized stool‐processing procedure, the sensor enabled detection of C. difficile infection in 38 human stool samples, demonstrating 94.7% concordance with the current gold‐standard polymerase chain reaction method. These results demonstrate a promising platform for enrichment‐free, point‐of‐care diagnosis of infectious diseases in clinic settings.
- 5 September 2026
- Published by Wiley in Advanced Materials
- Vol. 38 (56)
Open AccessLab‐in‐a‐Tube System Integrating Hierarchically Wrinkled Electrodes and DNAzyme‐Functionalized Beads for Diagnosis of Clostridioides difficile Infection
The diagnosis of bacterial infections remains slow because many existing methods rely on enrichment steps such as nucleic acid amplification or growth culture. RNA‐cleaving DNAzymes offer a promising route to accelerate bacterial diagnosis because they can be selected and programmed to specifically recognize disease‐causing bacteria and generate reporter DNA strands for signal readout. However, integrating DNAzymes into biosensors capable of analyzing complex biological matrices remains challenging, as matrix‐associated interferents can destabilize DNAzymes, suppress catalytic activity, and compromise signal detection. Here, we integrate redox RNA‐cleaving DNAzymes housed on antifouling magnetic beads with a lab‐in‐a‐tube platform that incorporates hierarchically structured sensing electrodes within a tubular flow cell for enrichment‐free detection of Clostridioides difficile in stool samples. The combination of antifouling magnetic beads and fluidic replenishment of DNA reporters across the hierarchical electrodes reduces nonspecific binding and enhances reporter capture efficiency, achieving a limit of detection as low as 1.3 × 10 2 CFU mL −1 in buffer. Using an optimized stool‐processing procedure, the sensor enabled detection of C. difficile infection in 38 human stool samples, demonstrating 94.7% concordance with the current gold‐standard polymerase chain reaction method. These results demonstrate a promising platform for enrichment‐free, point‐of‐care diagnosis of infectious diseases in clinic settings.
- Open Access
- 1 April 2026
- Published by Wiley in Chemistry–Methods
- Vol. 6 (4) , e70099
Preserving DNAzyme Stability and Activity in Stool Samples for Clinical Diagnostics
Stool is one of the most challenging biological matrices for functional nucleic acid–based diagnostics because of its high and variable nuclease activity. Here, we present a simple and robust strategy for stabilizing RNA‐cleaving fluorogenic DNAzymes (RFD) while preserving their catalytic function in stool. Using RFD‐CD3—a DNAzyme previously developed for Clostridioides difficile detection—as a model system, we evaluated two stabilization approaches. While nucleic acid competitors, including tRNA and salmon sperm DNA, provided only modest protection under alkaline conditions, heparin treatment combined with high‐pH buffer conditions significantly enhanced DNAzyme stability without compromising catalytic activity. This approach proved effective in both pooled and individual stool samples. The generality of the strategy was further demonstrated using RFD‐CD2, a sequence‐divergent C. difficile ‐responsive DNAzyme, as well as RFD‐EC1, which targets Escherichia coli K12. Across all tested DNAzymes, stabilization preserved both probe integrity and target‐responsive catalytic function. Together, these findings establish a practical and broadly applicable platform for deploying DNAzyme‐based diagnostics in complex clinical samples such as stool.
- 1 April 2026
- Published by Wiley in Chemistry–Methods
- Vol. 6 (4) , e70099
Open AccessPreserving DNAzyme Stability and Activity in Stool Samples for Clinical Diagnostics
Stool is one of the most challenging biological matrices for functional nucleic acid–based diagnostics because of its high and variable nuclease activity. Here, we present a simple and robust strategy for stabilizing RNA‐cleaving fluorogenic DNAzymes (RFD) while preserving their catalytic function in stool. Using RFD‐CD3—a DNAzyme previously developed for Clostridioides difficile detection—as a model system, we evaluated two stabilization approaches. While nucleic acid competitors, including tRNA and salmon sperm DNA, provided only modest protection under alkaline conditions, heparin treatment combined with high‐pH buffer conditions significantly enhanced DNAzyme stability without compromising catalytic activity. This approach proved effective in both pooled and individual stool samples. The generality of the strategy was further demonstrated using RFD‐CD2, a sequence‐divergent C. difficile ‐responsive DNAzyme, as well as RFD‐EC1, which targets Escherichia coli K12. Across all tested DNAzymes, stabilization preserved both probe integrity and target‐responsive catalytic function. Together, these findings establish a practical and broadly applicable platform for deploying DNAzyme‐based diagnostics in complex clinical samples such as stool.
- Open Access
- 12 March 2026
- Published by Wiley in ChemistryEurope
- Vol. 4 (3) , e202500352
Discovery of a Dual‐Target DNAzyme for Clostridioides difficile and Listeria monocytogenes Diagnostics
Rapid and reliable detection of Clostridioides difficile is essential for clinical diagnosis and infection control. Building on our group's prior development of RNA‐cleaving fluorogenic DNAzymes (RFDs) for bacterial recognition, we report RFD‐CD3, a fluorogenic DNAzyme with the highest catalytic efficiency reported to date for C. difficile‐responsive DNAzymes, achieving a detection limit of 10 3 CFU/mL and a catalytic rate constant (k obs ) of 0.16 min −1 for its engineered trans‐acting variant (RFD‐CD3‐TM2). This trans‐acting form also retains high activity and provides modularity for biosensor design, further extending the versatility of this platform. Unexpectedly, RFD‐CD3 also responds to Listeria monocytogenes , making it the first DNAzyme known to be selectively activated by two phylogenetically distinct bacterial species. As no RFD has previously been reported for L. monocytogenes, this discovery opens new opportunities for DNAzyme‐based biosensing of a clinically and food‐relevant pathogen. The distinct clinical contexts of the two targets—C. difficile in stool and L. monocytogenes in blood or food—highlight the potential of RFD‐CD3 as a versatile molecular tool suited to multiple diagnostic applications. RFD‐CD3 also remains catalytically active at alkaline pH, enhancing its stability in nuclease‐rich biological samples. Together, these features position RFD‐CD3 as a promising dual‐target platform for high‐performance diagnostics in both clinical and food safety applications
- 12 March 2026
- Published by Wiley in ChemistryEurope
- Vol. 4 (3) , e202500352
Open AccessDiscovery of a Dual‐Target DNAzyme for Clostridioides difficile and Listeria monocytogenes Diagnostics
Rapid and reliable detection of Clostridioides difficile is essential for clinical diagnosis and infection control. Building on our group's prior development of RNA‐cleaving fluorogenic DNAzymes (RFDs) for bacterial recognition, we report RFD‐CD3, a fluorogenic DNAzyme with the highest catalytic efficiency reported to date for C. difficile‐responsive DNAzymes, achieving a detection limit of 10 3 CFU/mL and a catalytic rate constant (k obs ) of 0.16 min −1 for its engineered trans‐acting variant (RFD‐CD3‐TM2). This trans‐acting form also retains high activity and provides modularity for biosensor design, further extending the versatility of this platform. Unexpectedly, RFD‐CD3 also responds to Listeria monocytogenes , making it the first DNAzyme known to be selectively activated by two phylogenetically distinct bacterial species. As no RFD has previously been reported for L. monocytogenes, this discovery opens new opportunities for DNAzyme‐based biosensing of a clinically and food‐relevant pathogen. The distinct clinical contexts of the two targets—C. difficile in stool and L. monocytogenes in blood or food—highlight the potential of RFD‐CD3 as a versatile molecular tool suited to multiple diagnostic applications. RFD‐CD3 also remains catalytically active at alkaline pH, enhancing its stability in nuclease‐rich biological samples. Together, these features position RFD‐CD3 as a promising dual‐target platform for high‐performance diagnostics in both clinical and food safety applications
- Open Access
- 14 January 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Discovery of a Dual-Target DNAzyme for Clostridioides difficile and Listeria monocytogenes Diagnostics
Rapid and reliable detection of Clostridioides difficile is essential for clinical diagnosis and infection control. Building on our group’s prior development of RNA-cleaving fluorogenic DNAzymes (RFDs) for bacterial recognition, we report RFD-CD3, a fluorogenic DNAzyme with the highest catalytic efficiency reported to date for C. difficile-responsive DNAzymes, achieving a detection limit of 10³ CFU/mL and a catalytic rate constant (kobs) of 0.16 min⁻¹ for its engineered trans-acting variant (RFD-CD3-TM2). This trans-acting form also retains high activity and provides modularity for biosensor design, further extending the versatility of this platform. Unexpectedly, RFD-CD3 also responds to Listeria monocytogenes, making it the first DNAzyme known to be selectively activated by two phylogenetically distinct bacterial species. As no RFD has previously been reported for L. monocytogenes, this discovery opens new opportunities for DNAzyme-based biosensing of a clinically and food-relevant pathogen. The distinct clinical contexts of the two targets—C. difficile in stool and L. monocytogenes in blood or food—highlight the potential of RFD-CD3 as a versatile molecular tool suited to multiple diagnostic applications. RFD-CD3 also remains catalytically active at alkaline pH, enhancing its stability in nuclease-rich biological samples. Together, these features position RFD-CD3 as a promising dual-target platform for high-performance diagnostics in both clinical and food safety applications.
- 14 January 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessDiscovery of a Dual-Target DNAzyme for Clostridioides difficile and Listeria monocytogenes Diagnostics
Rapid and reliable detection of Clostridioides difficile is essential for clinical diagnosis and infection control. Building on our group’s prior development of RNA-cleaving fluorogenic DNAzymes (RFDs) for bacterial recognition, we report RFD-CD3, a fluorogenic DNAzyme with the highest catalytic efficiency reported to date for C. difficile-responsive DNAzymes, achieving a detection limit of 10³ CFU/mL and a catalytic rate constant (kobs) of 0.16 min⁻¹ for its engineered trans-acting variant (RFD-CD3-TM2). This trans-acting form also retains high activity and provides modularity for biosensor design, further extending the versatility of this platform. Unexpectedly, RFD-CD3 also responds to Listeria monocytogenes, making it the first DNAzyme known to be selectively activated by two phylogenetically distinct bacterial species. As no RFD has previously been reported for L. monocytogenes, this discovery opens new opportunities for DNAzyme-based biosensing of a clinically and food-relevant pathogen. The distinct clinical contexts of the two targets—C. difficile in stool and L. monocytogenes in blood or food—highlight the potential of RFD-CD3 as a versatile molecular tool suited to multiple diagnostic applications. RFD-CD3 also remains catalytically active at alkaline pH, enhancing its stability in nuclease-rich biological samples. Together, these features position RFD-CD3 as a promising dual-target platform for high-performance diagnostics in both clinical and food safety applications.