Francisco P. Oliveira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Francisco P. Oliveira has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Diogo Santos-Ferreira
Cardiology Department, Unidade Local de Saúde de Gaia e Espinho, R. Conceição Fernandes, s/n, 4434-502 Vila Nova de Gaia, Portugal
2 shared publications - Nuno Ferreira
Department of Cardiology, Unidade Local de Saúde de Gaia e Espinho, Vila Nova de Gaia, Portugal
2 shared publications - Ricardo Ladeiras-Lopes
Cardiovascular Research and Development Centre-UnIC@RISE, Department of Surgery and Physiology, Faculty of Medicine of the University of Porto , Porto
2 shared publications - Sónia Isabel Silva Pinto
Engineering Faculty, University of Porto, Rua Dr. Roberto Frias, s/n, 4200-465 Porto, Portugal
2 shared publications - Christian Gil
Universidade de Vigo
1 shared publication - Concepción Paz
Universidade de Vigo
1 shared publication
Latest Publications
- Open Access
- 23 January 2026
- Published by MDPI AG in Mathematics
- Vol. 14 (3) , 395
A Computational Framework for FFR Estimation in Right Coronary Arteries: From CFD Simulation to Clinical Validation
Coronary artery disease (CAD) remains the leading cause of cardiovascular mortality worldwide. Accurate and non-invasive quantification of coronary hemodynamics, namely in the right coronary artery (RCA), is essential for clinical decision-making but remains challenging due to the complex interaction among vessel geometry, pulsatile flow, and blood rheology. This study presents and validates a transparent computational framework for non-invasive fractional flow reserve (FFR) estimation using patient-specific RCA geometries reconstructed from coronary computed tomography angiography (CCTA) using SimVascular 27-03-2023. The proposed workflow integrates realistic boundary conditions through a Womersley velocity profile and a three-element Windkessel outlet model, coupled with a viscoelastic blood rheology formulation (sPTT) implemented via user-defined functions (UDFs). This work integrates all clinically relevant conditions of invasive FFR assessment into a single patient-specific computational framework, while delivering results within a time frame compatible with clinical practice, representing a meaningful methodological advance. The methodology was applied to seven patient-specific cases, and the resulting non-invasive FFR values were compared with both invasive wire-based measurements and commercial HeartFlow® outputs (Mountain View, CA, USA). Under hyperemic conditions, the computed FFR values showed strong agreement with invasive references, with a mean relative error of 8.4% ± 6.3%, showing diagnostic consistency similar to that of HeartFlow® (8.3% ± 8.1%) for the selected dataset. These findings demonstrate the ability of the proposed CFD-based pipeline to accurately replicate physiological coronary behavior under hyperemia. This novel workflow provides a fully on-site, open-source, reproducible, and cost-effective framework. Ultimately, this study advances the clinical applicability of non-invasive CFD tools for the functional assessment of CAD, particularly in the RCA.
- 23 January 2026
- Published by MDPI AG in Mathematics
- Vol. 14 (3) , 395
Open AccessA Computational Framework for FFR Estimation in Right Coronary Arteries: From CFD Simulation to Clinical Validation
Coronary artery disease (CAD) remains the leading cause of cardiovascular mortality worldwide. Accurate and non-invasive quantification of coronary hemodynamics, namely in the right coronary artery (RCA), is essential for clinical decision-making but remains challenging due to the complex interaction among vessel geometry, pulsatile flow, and blood rheology. This study presents and validates a transparent computational framework for non-invasive fractional flow reserve (FFR) estimation using patient-specific RCA geometries reconstructed from coronary computed tomography angiography (CCTA) using SimVascular 27-03-2023. The proposed workflow integrates realistic boundary conditions through a Womersley velocity profile and a three-element Windkessel outlet model, coupled with a viscoelastic blood rheology formulation (sPTT) implemented via user-defined functions (UDFs). This work integrates all clinically relevant conditions of invasive FFR assessment into a single patient-specific computational framework, while delivering results within a time frame compatible with clinical practice, representing a meaningful methodological advance. The methodology was applied to seven patient-specific cases, and the resulting non-invasive FFR values were compared with both invasive wire-based measurements and commercial HeartFlow® outputs (Mountain View, CA, USA). Under hyperemic conditions, the computed FFR values showed strong agreement with invasive references, with a mean relative error of 8.4% ± 6.3%, showing diagnostic consistency similar to that of HeartFlow® (8.3% ± 8.1%) for the selected dataset. These findings demonstrate the ability of the proposed CFD-based pipeline to accurately replicate physiological coronary behavior under hyperemia. This novel workflow provides a fully on-site, open-source, reproducible, and cost-effective framework. Ultimately, this study advances the clinical applicability of non-invasive CFD tools for the functional assessment of CAD, particularly in the RCA.
- 16 January 2026
- Published by Elsevier in International Journal of Non-Linear Mechanics
- Vol. 183-184
Analysis of arterial wall mechanics in right coronary artery obstructive disease: FSI modelling and non-invasive FFR validation
- 16 January 2026
- Published by Elsevier in International Journal of Non-Linear Mechanics
- Vol. 183-184
Analysis of arterial wall mechanics in right coronary artery obstructive disease: FSI modelling and non-invasive FFR validation