Siyeon An
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Siyeon An has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Dong-Soo Han
Center for Spintronics, Korea Institute of Science and Technology (KIST) 2 , Seoul
2 shared publications - Akashdeep Akashdeep
Johannes Gutenberg University Mainz
1 shared publication - Andreas Suter
PSI – Center for Neutron and Muon Sciences CNM
1 shared publication - Angelo Di Bernardo
Department of Physics, University of Konstanz, Konstanz, Germany
1 shared publication Eojin Lee
Department of Materials Science and Engineering Kyung Hee University Yongin Republic of Korea
1 shared publication- Eun Saem Kang
Center for Neuroscience Imaging Research Institute for Basic Science (IBS) Suwon Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 28 October 2026
- Published by Wiley in Advanced Materials
- p. e75549
Continuous and Wireless Monitoring of Myocardial Dynamics Using Biocompatible Magneto‐Viscoelastic Patches
We report a machine learning (ML)‐augmented magnetic sensing system for real‐time, wireless monitoring of cardiac kinematics during recovery following surgery. While conventional monitoring focuses on electrical activity, it overlooks mechanical performance and pumping efficiency. To bridge this diagnostic gap, we developed a biocompatible magnetic particle matrix (MPM) patch incorporating biocompatible ferromagnetic α″‐Fe 16 N 2 microparticles. By integrating this patch onto the epicardium during surgery, our platform enables passive magnetic readout and analysis of epicardial motion without implanted electronics. The system utilizes an external magnetometer to sense 3D magnetic field vectors generated during cardiac contraction and relaxation. By employing a ML‐based regression model, we translate dynamic magnetic field variations into precise 3D spatial coordinates to reconstruct the heart's motion. Beyond positional tracking, this framework enables extraction of clinical‐grade myocardial velocity profiles, delivering real‐time assessment of cardiac health. In vivo studies in rodent models demonstrate the patch resolves cardiac mechanical motion and quantifies acute diastolic dysfunction, revealing pathological shifts undetected by surface ECG. Furthermore, the absence of adverse tissue responses and negligible systemic toxicity after 12 weeks of implantation underscores the biocompatibility of the magnetic particles. These findings establish a foundation for untethered monitoring of cardiac kinematics and suggest an approach for tracking internal organs.
- 28 October 2026
- Published by Wiley in Advanced Materials
- p. e75549
Open AccessContinuous and Wireless Monitoring of Myocardial Dynamics Using Biocompatible Magneto‐Viscoelastic Patches
We report a machine learning (ML)‐augmented magnetic sensing system for real‐time, wireless monitoring of cardiac kinematics during recovery following surgery. While conventional monitoring focuses on electrical activity, it overlooks mechanical performance and pumping efficiency. To bridge this diagnostic gap, we developed a biocompatible magnetic particle matrix (MPM) patch incorporating biocompatible ferromagnetic α″‐Fe 16 N 2 microparticles. By integrating this patch onto the epicardium during surgery, our platform enables passive magnetic readout and analysis of epicardial motion without implanted electronics. The system utilizes an external magnetometer to sense 3D magnetic field vectors generated during cardiac contraction and relaxation. By employing a ML‐based regression model, we translate dynamic magnetic field variations into precise 3D spatial coordinates to reconstruct the heart's motion. Beyond positional tracking, this framework enables extraction of clinical‐grade myocardial velocity profiles, delivering real‐time assessment of cardiac health. In vivo studies in rodent models demonstrate the patch resolves cardiac mechanical motion and quantifies acute diastolic dysfunction, revealing pathological shifts undetected by surface ECG. Furthermore, the absence of adverse tissue responses and negligible systemic toxicity after 12 weeks of implantation underscores the biocompatibility of the magnetic particles. These findings establish a foundation for untethered monitoring of cardiac kinematics and suggest an approach for tracking internal organs.
- 12 January 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (2)
Surface-localized magnetic order in RuO2 thin films revealed by low-energy muon probes
Ruthenium dioxide (RuO2) has recently emerged as an altermagnetic candidate, but its intrinsic magnetic ground state in thin films remains widely debated. This study aims to clarify the nature and spatial extent of the magnetic order in RuO2 thin films grown under different conditions. Thin films of RuO2 with thicknesses of 30 and 33 nm are deposited by pulsed laser deposition and sputtering onto TiO2(110) and Al2O3(1¯102) substrates, respectively. Low-energy muon spin rotation/relaxation (LE-μSR) with depth-resolved sensitivity measurements is performed in transverse magnetic fields (TF) from 4 K to 290 K. The μSR data collected with a muon implantation energy of 1 keV reveal that magnetic signals originate from the near-surface region of the film (≲10 nm), and the affected volume fraction is approximately 8.5%. The localized magnetic response is consistent across different substrates, growth techniques, and parameter sets, suggesting a common origin related to surface defects and dimensionality effects. The combined use of TF-μSR and the study of depth-dependent implantation with low-energy muons provides direct evidence for surface-confined, inhomogeneous static magnetic order in RuO2 thin films, helping reconcile discrepancies. These findings underscore the importance of considering reduced-dimensional contributions and motivate further investigation into the role of defects, strain, and stoichiometry on the magnetic properties of RuO2, especially at the surface.
- 12 January 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (2)
Surface-localized magnetic order in RuO2 thin films revealed by low-energy muon probes
Ruthenium dioxide (RuO2) has recently emerged as an altermagnetic candidate, but its intrinsic magnetic ground state in thin films remains widely debated. This study aims to clarify the nature and spatial extent of the magnetic order in RuO2 thin films grown under different conditions. Thin films of RuO2 with thicknesses of 30 and 33 nm are deposited by pulsed laser deposition and sputtering onto TiO2(110) and Al2O3(1¯102) substrates, respectively. Low-energy muon spin rotation/relaxation (LE-μSR) with depth-resolved sensitivity measurements is performed in transverse magnetic fields (TF) from 4 K to 290 K. The μSR data collected with a muon implantation energy of 1 keV reveal that magnetic signals originate from the near-surface region of the film (≲10 nm), and the affected volume fraction is approximately 8.5%. The localized magnetic response is consistent across different substrates, growth techniques, and parameter sets, suggesting a common origin related to surface defects and dimensionality effects. The combined use of TF-μSR and the study of depth-dependent implantation with low-energy muons provides direct evidence for surface-confined, inhomogeneous static magnetic order in RuO2 thin films, helping reconcile discrepancies. These findings underscore the importance of considering reduced-dimensional contributions and motivate further investigation into the role of defects, strain, and stoichiometry on the magnetic properties of RuO2, especially at the surface.