Chenyang Yao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chenyang Yao has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Jie Lu
Department of Radiology and Nuclear Medicine, Xuanwu Hospital, Capital Medical University, Beijing, China
3 shared publications - Yi Shan
Department of Radiology and Nuclear Medicine, Xuan Wu Hospital of the Capital Medical University, Beijing, China
2 shared publications Zhen‐Ming Wang
Department of Radiation Oncology Xuanwu Hospital, Capital Medical University Beijing China
2 shared publicationsBixiao Cui
Department of Radiology and Nuclear Medicine Xuanwu Hospital Capital Medical University Beijing China
1 shared publication- Bixiao Cui
Department of Radiology and Nuclear Medicine, Xuan Wu Hospital of the Capital Medical University, Beijing, China
1 shared publication Chunxue Wu
Department of Radiology and Nuclear Medicine Xuanwu Hospital Capital Medical University Beijing China
1 shared publication
Latest Publications
- Open Access
- 23 November 2026
- Published by Wiley in CNS Neuroscience & Therapeutics
- Vol. 32 (11)
Morphometric Similarity Network–Based Structural MRI Analysis of Network Reorganization in Temporal Lobe Glioblastoma
Purpose: To quantify brain‐wide morphometric similarity network (MSN) reorganization in temporal‐lobe glioblastoma on post‐treatment MRI and relate it to lesion burden and longitudinal change. Methods: We analyzed 137 temporal‐lobe glioblastoma cases from BraTS and 102 healthy controls from OASIS‐1. MSNs were constructed from T1 morphometrics. Cross‐sectionally, one analysis‐eligible index scan per patient was used (small vs. large lesion volume). Longitudinal change was assessed between the index scan and the last eligible follow‐up; system‐level effects were summarized in Yeo‐7 networks. Results: Nodal MSN strength showed ipsi‐contralateral dissociation: In left/right‐temporal GBM, ipsilateral temporal strength decreased ( t = −1.37/−1.72), whereas contralateral temporal ( t = 7.00/8.11) and insular strength ( t = 8.42/11.73) increased. With increasing lesion volume, network segregation declined most prominently in left‐temporal tumors (clustering coefficient: 0.7559 to 0.7128, small‐worldness: 1.5018 to 1.4111, assortativity: 0.3243 to 0.2814, modularity: 0.3356 to 0.2959), while integration was relatively preserved. Longitudinally, Δvolume correlated with Δglobal efficiency ( r = 0.551, p = 1.61 × 10 −5 ) and Δcharacteristic path length ( r = −0.511, p = 7.79 × 10 −5 ) in right‐temporal tumors, but with Δmodularity in left‐temporal tumors ( r = −0.467, p = 5.34 × 10 −3 ). ΔVolume also correlated with within‐network MSN strength in the default mode and dorsal attention network. Conclusion: MSN edge increases/decreases indicate higher/lower morphometric similarity; these post‐treatment network markers complement lesion size by highlighting distributed system vulnerability for follow‐up.
- 23 November 2026
- Published by Wiley in CNS Neuroscience & Therapeutics
- Vol. 32 (11)
Open AccessMorphometric Similarity Network–Based Structural MRI Analysis of Network Reorganization in Temporal Lobe Glioblastoma
Purpose: To quantify brain‐wide morphometric similarity network (MSN) reorganization in temporal‐lobe glioblastoma on post‐treatment MRI and relate it to lesion burden and longitudinal change. Methods: We analyzed 137 temporal‐lobe glioblastoma cases from BraTS and 102 healthy controls from OASIS‐1. MSNs were constructed from T1 morphometrics. Cross‐sectionally, one analysis‐eligible index scan per patient was used (small vs. large lesion volume). Longitudinal change was assessed between the index scan and the last eligible follow‐up; system‐level effects were summarized in Yeo‐7 networks. Results: Nodal MSN strength showed ipsi‐contralateral dissociation: In left/right‐temporal GBM, ipsilateral temporal strength decreased ( t = −1.37/−1.72), whereas contralateral temporal ( t = 7.00/8.11) and insular strength ( t = 8.42/11.73) increased. With increasing lesion volume, network segregation declined most prominently in left‐temporal tumors (clustering coefficient: 0.7559 to 0.7128, small‐worldness: 1.5018 to 1.4111, assortativity: 0.3243 to 0.2814, modularity: 0.3356 to 0.2959), while integration was relatively preserved. Longitudinally, Δvolume correlated with Δglobal efficiency ( r = 0.551, p = 1.61 × 10 −5 ) and Δcharacteristic path length ( r = −0.511, p = 7.79 × 10 −5 ) in right‐temporal tumors, but with Δmodularity in left‐temporal tumors ( r = −0.467, p = 5.34 × 10 −3 ). ΔVolume also correlated with within‐network MSN strength in the default mode and dorsal attention network. Conclusion: MSN edge increases/decreases indicate higher/lower morphometric similarity; these post‐treatment network markers complement lesion size by highlighting distributed system vulnerability for follow‐up.
- 11 November 2026
- Published by Springer Nature in Neuroradiology
- p. 1-10
MRI-derived synthetic [¹⁸F]FET PET in neuro-oncology: evaluation in glioma grading and differentiation from solitary brain metastasis
Background O-(2-[18F]fluoroethyl)-L-tyrosine positron emission tomography ([18F]FET PET) is clinically useful in neuro-oncology but limited by cost and availability. We assessed the clinical utility of magnetic resonance imaging (MRI)-derived synthetic [18F]FET PET. Methods A total of 489 patients with histologically confirmed gliomas or brain metastases were retrospectively analyzed. A deep learning model generated synthetic PET images from multimodal MRI in the overall cohort and subgroups. Synthetic PET was evaluated against reference PET for image similarity by peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM), standardized uptake value ratio (SUVR) analysis by Pearson correlation and Bland–Altman analysis, and blinded reader assessment for glioma grading and high-grade glioma (HGG) versus solitary brain metastasis (SBM) differentiation using receiver operating characteristic analysis with area under the curve (AUC). Results Synthetic PET showed high similarity to reference PET in the overall, glioma, and metastasis groups (PSNR, 34.7–35.5 dB; SSIM, 0.90–0.96), and SUVR correlations were strong (r = 0.77–0.93, all P < 0.001), with minimal bias and narrow limits of agreement. Compared with MRI alone, MRI with synthetic PET improved glioma grading and HGG–SBM differentiation, increasing AUC from 0.815 to 0.941 and from 0.816 to 0.901 for glioma grading and from 0.731 to 0.871 and from 0.784 to 0.872 for HGG–SBM differentiation across the 2 readers (all P < 0.05). No significant differences were found between MRI with synthetic and reference PET for either task (all P > 0.05). Conclusions MRI-derived synthetic [18F]FET PET may enhance glioma grading and HGG–SBM differentiation, providing a PET-like alternative when FET PET is unavailable.
- 11 November 2026
- Published by Springer Nature in Neuroradiology
- p. 1-10
MRI-derived synthetic [¹⁸F]FET PET in neuro-oncology: evaluation in glioma grading and differentiation from solitary brain metastasis
Background O-(2-[18F]fluoroethyl)-L-tyrosine positron emission tomography ([18F]FET PET) is clinically useful in neuro-oncology but limited by cost and availability. We assessed the clinical utility of magnetic resonance imaging (MRI)-derived synthetic [18F]FET PET. Methods A total of 489 patients with histologically confirmed gliomas or brain metastases were retrospectively analyzed. A deep learning model generated synthetic PET images from multimodal MRI in the overall cohort and subgroups. Synthetic PET was evaluated against reference PET for image similarity by peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM), standardized uptake value ratio (SUVR) analysis by Pearson correlation and Bland–Altman analysis, and blinded reader assessment for glioma grading and high-grade glioma (HGG) versus solitary brain metastasis (SBM) differentiation using receiver operating characteristic analysis with area under the curve (AUC). Results Synthetic PET showed high similarity to reference PET in the overall, glioma, and metastasis groups (PSNR, 34.7–35.5 dB; SSIM, 0.90–0.96), and SUVR correlations were strong (r = 0.77–0.93, all P < 0.001), with minimal bias and narrow limits of agreement. Compared with MRI alone, MRI with synthetic PET improved glioma grading and HGG–SBM differentiation, increasing AUC from 0.815 to 0.941 and from 0.816 to 0.901 for glioma grading and from 0.731 to 0.871 and from 0.784 to 0.872 for HGG–SBM differentiation across the 2 readers (all P < 0.05). No significant differences were found between MRI with synthetic and reference PET for either task (all P > 0.05). Conclusions MRI-derived synthetic [18F]FET PET may enhance glioma grading and HGG–SBM differentiation, providing a PET-like alternative when FET PET is unavailable.
Magnetic resonance imaging ‐based ranking of resection‐related cortical candidates for presurgical localization in epilepsy using a prior‐aware graph attention transformer
Objective: Structural magnetic resonance imaging (MRI) is fundamental to presurgical localization in epilepsy, but subtle epilepsy‐related abnormalities may not always be apparent on routine review. This study aimed to develop and externally validate an MRI‐only graph attention transformer for ranking resection‐related cortical candidates and to evaluate its reader‐level utility. Methods: Graph Attention Transformer for Epilepsy‐Related Candidate Zones (GATEZ) was developed using preoperative three‐dimensional T1‐weighted MRI from the publicly released IDEAS (Imaging Database for Epilepsy and Surgery) database. Participants with a 12‐month International League Against Epilepsy class 1 outcome were split into training, validation, and internal test sets ( n = 171/37/37). Each participant was represented as a 1000‐parcel cortical graph with five regional morphometric features and an individualized Morphometric Inverse Divergence network; postoperative resection masks served as the surgical reference standard for model supervision. External validation used 183 consecutive surgical participants with epilepsy who underwent hybrid 18 F‐fluorodeoxyglucose ( 18 F‐FDG) positron emission tomography (PET)/MRI, with MRI only used for model inference. Reader‐level utility was evaluated in a blinded three‐reader study comparing MRI alone, MRI plus 18 F‐FDG PET, and MRI plus GATEZ. Results: In the internal test cohort, GATEZ placed at least one resection‐overlapping parcel within the Top‐10 ranked candidates in 92% of participants, with a mean Top‐10 positive predictive value of 62%. Performance remained stable in the independent external cohort, with an 87% Top‐10 hit rate and 59% mean Top‐10 positive predictive value. Node‐level area under the precision–recall curve was .29 internally and .27 externally, indicating stable enrichment of resection‐related regions among the highest ranked candidates. In the blinded reader study, MRI + GATEZ improved detection compared with MRI alone (74%–78% vs. 58%–66% across readers; adjusted p ≤ .001 for all readers) and performed similarly to MRI + FDG (78%–80% across readers; adjusted p ≥ .34 for all readers). Significance: GATEZ generates a concise Top‐ K shortlist of resection‐related cortical candidates and may serve as a practical second‐look aid for presurgical localization.
Magnetic resonance imaging ‐based ranking of resection‐related cortical candidates for presurgical localization in epilepsy using a prior‐aware graph attention transformer
Objective: Structural magnetic resonance imaging (MRI) is fundamental to presurgical localization in epilepsy, but subtle epilepsy‐related abnormalities may not always be apparent on routine review. This study aimed to develop and externally validate an MRI‐only graph attention transformer for ranking resection‐related cortical candidates and to evaluate its reader‐level utility. Methods: Graph Attention Transformer for Epilepsy‐Related Candidate Zones (GATEZ) was developed using preoperative three‐dimensional T1‐weighted MRI from the publicly released IDEAS (Imaging Database for Epilepsy and Surgery) database. Participants with a 12‐month International League Against Epilepsy class 1 outcome were split into training, validation, and internal test sets ( n = 171/37/37). Each participant was represented as a 1000‐parcel cortical graph with five regional morphometric features and an individualized Morphometric Inverse Divergence network; postoperative resection masks served as the surgical reference standard for model supervision. External validation used 183 consecutive surgical participants with epilepsy who underwent hybrid 18 F‐fluorodeoxyglucose ( 18 F‐FDG) positron emission tomography (PET)/MRI, with MRI only used for model inference. Reader‐level utility was evaluated in a blinded three‐reader study comparing MRI alone, MRI plus 18 F‐FDG PET, and MRI plus GATEZ. Results: In the internal test cohort, GATEZ placed at least one resection‐overlapping parcel within the Top‐10 ranked candidates in 92% of participants, with a mean Top‐10 positive predictive value of 62%. Performance remained stable in the independent external cohort, with an 87% Top‐10 hit rate and 59% mean Top‐10 positive predictive value. Node‐level area under the precision–recall curve was .29 internally and .27 externally, indicating stable enrichment of resection‐related regions among the highest ranked candidates. In the blinded reader study, MRI + GATEZ improved detection compared with MRI alone (74%–78% vs. 58%–66% across readers; adjusted p ≤ .001 for all readers) and performed similarly to MRI + FDG (78%–80% across readers; adjusted p ≥ .34 for all readers). Significance: GATEZ generates a concise Top‐ K shortlist of resection‐related cortical candidates and may serve as a practical second‐look aid for presurgical localization.
- 16 January 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (5) , 1292-1305
Multisequence MRI Enables High‐Fidelity FDG ‐ PET Synthesis for Epilepsy Using GANs
Background: FDG‐PET aids presurgical epilepsy evaluation but is limited by access and radiation exposure. Purpose: To evaluate synthetic FDG‐PET generated from T1‐weighted imaging and resting‐state fMRI metrics. Study Type: Retrospective. Population: 481 participants underwent simultaneous FDG PET/MR. Internal cohort: 311 epilepsy patients split into training/validation/internal test sets ( n = 249/31/31; age 18.79 ± 16.33/22.20 ± 11.21/21.65 ± 17.62 years; male/female 145/104, 13/18, 22/9). External cohort: 115 temporal lobe epilepsy patients (age 25.36 ± 10.95 years; male/female 68/47) and 55 healthy controls (age 27.62 ± 5.82 years; male/female 24/31); 92 had surgery with 1‐year outcome. Field Strength: Hybrid PET/MR at 3.0 T; gradient‐echo T1WI, echo‐planar imaging and resting‐state BOLD gradient‐echo EPI. Assessment: Performance was assessed using SSIM, PSNR, MSE, NRMSE, SUVR correlation, and Bland–Altman analysis. Three blinded readers performed visual quality grading and detection of temporal lobe hypometabolism. Hippocampal radiomics was used for classification of hippocampal sclerosis and Engel outcome. Statistical Tests: t ‐tests, chi‐square tests, Pearson correlation, Kolmogorov–Smirnov tests, DeLong tests, and false discovery rate correction. Results: Excellent/Good visual ratings occurred in 82.8% (166/201), with Fleiss' κ = 0.42. SSIM was 0.98 ± 0.01 (internal) and 0.97 ± 0.01 (external); PSNR was 66.66 ± 1.25 and 64.16 ± 1.83, respectively. SUVR correlation with ground‐truth PET was r = 0.94 (internal) and r = 0.89 (external); Bland–Altman bias was −0.02 (95% limits of agreement: −0.22 to 0.18) internally and −0.00002 (95% limits: −0.35 to 0.35) externally. Detection accuracy for temporal hypometabolism was 90.3% (internal; κ = 0.735) and 87.1% (external; κ = 0.758). Radiomics AUCs using synthetic PET were 0.72 (95% CI: 0.62–0.83) for hippocampal sclerosis versus healthy controls and 0.77 (95% CI: 0.67–0.87) for Engel IA versus IB–IV; DeLong tests versus ground‐truth PET were non‐significant ( p = 0.56 and p = 0.48). Conclusion: Multisequence MRI‐based synthetic PET showed high agreement with ground‐truth PET across image‐quality and quantitative SUVR metrics, providing a PET‐like metabolic surrogate when FDG‐PET is unavailable or impractical. Level of Evidence: Evidence Level 3. Stages of Technical Efficacy: Stage 3.
- 16 January 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (5) , 1292-1305
Multisequence MRI Enables High‐Fidelity FDG ‐ PET Synthesis for Epilepsy Using GANs
Background: FDG‐PET aids presurgical epilepsy evaluation but is limited by access and radiation exposure. Purpose: To evaluate synthetic FDG‐PET generated from T1‐weighted imaging and resting‐state fMRI metrics. Study Type: Retrospective. Population: 481 participants underwent simultaneous FDG PET/MR. Internal cohort: 311 epilepsy patients split into training/validation/internal test sets ( n = 249/31/31; age 18.79 ± 16.33/22.20 ± 11.21/21.65 ± 17.62 years; male/female 145/104, 13/18, 22/9). External cohort: 115 temporal lobe epilepsy patients (age 25.36 ± 10.95 years; male/female 68/47) and 55 healthy controls (age 27.62 ± 5.82 years; male/female 24/31); 92 had surgery with 1‐year outcome. Field Strength: Hybrid PET/MR at 3.0 T; gradient‐echo T1WI, echo‐planar imaging and resting‐state BOLD gradient‐echo EPI. Assessment: Performance was assessed using SSIM, PSNR, MSE, NRMSE, SUVR correlation, and Bland–Altman analysis. Three blinded readers performed visual quality grading and detection of temporal lobe hypometabolism. Hippocampal radiomics was used for classification of hippocampal sclerosis and Engel outcome. Statistical Tests: t ‐tests, chi‐square tests, Pearson correlation, Kolmogorov–Smirnov tests, DeLong tests, and false discovery rate correction. Results: Excellent/Good visual ratings occurred in 82.8% (166/201), with Fleiss' κ = 0.42. SSIM was 0.98 ± 0.01 (internal) and 0.97 ± 0.01 (external); PSNR was 66.66 ± 1.25 and 64.16 ± 1.83, respectively. SUVR correlation with ground‐truth PET was r = 0.94 (internal) and r = 0.89 (external); Bland–Altman bias was −0.02 (95% limits of agreement: −0.22 to 0.18) internally and −0.00002 (95% limits: −0.35 to 0.35) externally. Detection accuracy for temporal hypometabolism was 90.3% (internal; κ = 0.735) and 87.1% (external; κ = 0.758). Radiomics AUCs using synthetic PET were 0.72 (95% CI: 0.62–0.83) for hippocampal sclerosis versus healthy controls and 0.77 (95% CI: 0.67–0.87) for Engel IA versus IB–IV; DeLong tests versus ground‐truth PET were non‐significant ( p = 0.56 and p = 0.48). Conclusion: Multisequence MRI‐based synthetic PET showed high agreement with ground‐truth PET across image‐quality and quantitative SUVR metrics, providing a PET‐like metabolic surrogate when FDG‐PET is unavailable or impractical. Level of Evidence: Evidence Level 3. Stages of Technical Efficacy: Stage 3.