Ella Fitzgerald
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ella Fitzgerald has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Vila Cabaleiro
Department of Clinical Sciences and Services, The Royal Veterinary College, University of London, Hertfordshire AL9 7TA, UK
2 shared publications - Alessia Cordella
Department of Clinical Sciences and Advanced Medicine, University of Pennsylvania School of Veterinary Medicine, Philadelphia, PA, USA
1 shared publication - Alessia Diana
Department of Veterinary Medical Science Alma Mater Studiorum, University of Bologna Ozzano Emilia (BO) Italy
1 shared publication - Cesar Llanos
Department of Clinical Sciences and Services, The Royal Veterinary College University of London Hertfordshire UK
1 shared publication - Dan Gerard O'NEill
Pathobiology and Population Sciences Royal Veterinary College Hatfield UK
1 shared publication - Emmelie Stock
Imaging, Orthopedics, Rehabilitation and Nutrition, Faculty of Veterinary Medicine, Ghent University Department of Morphology Merelbeke
1 shared publication
Latest Publications
- Open Access
- 1 September 2026
- Published by Wiley in Journal of Small Animal Practice
Non‐rim‐enhancing intracranial abscess in a cat confirmed by MRI and histopathology
- 1 September 2026
- Published by Wiley in Journal of Small Animal Practice
Open AccessNon‐rim‐enhancing intracranial abscess in a cat confirmed by MRI and histopathology
- 16 January 2026
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 67 (1) , e70138
Introduction and Validation of Radiographic Guidelines for Identification of Nasoesophageal and Nasogastric Tube Position in Dogs and Cats
Nasoesophageal and nasogastric feeding tubes are commonly used in dogs and cats, but inadvertent tracheal placement can cause serious complications. Although radiographs are widely used for confirming tube position, standardized interpretive guidelines are lacking. This study aimed to introduce and validate novel radiographic guidelines for improving tube position identification. Six blinded interpreters (one radiology intern, two emergency and critical care residents, one general practitioner, and two fourth‐year veterinary students) with varying clinical experience assessed tube positioning on 256 lateral canine and feline cervical/thoracic radiographs before and after receiving the guidelines. True tube position was determined by clinical history and radiographic assessment by two board‐certified radiologists. The proposed guidelines for identifying correctly positioned tubes included (1) incomplete superposition of the tube on the tracheal lumen, (2) dorsal tube position relative to the carina, and (3) relative to the larynx when included. The study included 129 esophageal‐positioned (correct) and 127 tracheal‐positioned (incorrect) radiographs with nasoesophageal/nasogastric tubes. The implementation of the radiographic guidelines significantly improved the correct identification of tube positioning, increasing from 82.1% pre‐guidelines to 95.8% post‐guidelines ( p < 0.001). Additionally, “uncertain” assessments decreased from 14.1% pre‐guidelines to 2.4% post‐guidelines ( p < 0.001). Before guidelines, interpreters correctly identified tube position in 89.1% of radiographs that included the larynx. However, guideline implementation did not significantly impact the correct interpretation of tube position assessment when the larynx was included. These results validate the clinical utility of a novel radiographic guideline to improve the accuracy and confidence of identification of nasoesophageal/nasogastric tube position in dogs and cats.
- 16 January 2026
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 67 (1) , e70138
Introduction and Validation of Radiographic Guidelines for Identification of Nasoesophageal and Nasogastric Tube Position in Dogs and Cats
Nasoesophageal and nasogastric feeding tubes are commonly used in dogs and cats, but inadvertent tracheal placement can cause serious complications. Although radiographs are widely used for confirming tube position, standardized interpretive guidelines are lacking. This study aimed to introduce and validate novel radiographic guidelines for improving tube position identification. Six blinded interpreters (one radiology intern, two emergency and critical care residents, one general practitioner, and two fourth‐year veterinary students) with varying clinical experience assessed tube positioning on 256 lateral canine and feline cervical/thoracic radiographs before and after receiving the guidelines. True tube position was determined by clinical history and radiographic assessment by two board‐certified radiologists. The proposed guidelines for identifying correctly positioned tubes included (1) incomplete superposition of the tube on the tracheal lumen, (2) dorsal tube position relative to the carina, and (3) relative to the larynx when included. The study included 129 esophageal‐positioned (correct) and 127 tracheal‐positioned (incorrect) radiographs with nasoesophageal/nasogastric tubes. The implementation of the radiographic guidelines significantly improved the correct identification of tube positioning, increasing from 82.1% pre‐guidelines to 95.8% post‐guidelines ( p < 0.001). Additionally, “uncertain” assessments decreased from 14.1% pre‐guidelines to 2.4% post‐guidelines ( p < 0.001). Before guidelines, interpreters correctly identified tube position in 89.1% of radiographs that included the larynx. However, guideline implementation did not significantly impact the correct interpretation of tube position assessment when the larynx was included. These results validate the clinical utility of a novel radiographic guideline to improve the accuracy and confidence of identification of nasoesophageal/nasogastric tube position in dogs and cats.