Xiangjiang Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiangjiang Tang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Caixia Jia
2 shared publications- Da He
University of Michigan-Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University, Shanghai, China
2 shared publications Jing Chen
2 shared publicationsShiyao Gu
2 shared publicationsBokai Hu
University of Michigan-Shanghai Jiao Tong University Joint Institute, Shanghai Jiao Tong University, Shanghai 200240, China; Department of Electrical and Computer Engineering, the University of California, San Diego, CA 92037, USA
1 shared publication- Caixia Jia
Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
1 shared publication
Latest Publications
- Open Access
- 6 August 2026
- Published by Elsevier in SSRN Electronic Journal
Deep Learning for Stenosis Assessment and Intraplaque Neovascularization Grading in Carotid Artery Using Contrast-Enhanced Ultrasound Video
Background: Contrast-enhanced ultrasound (CEUS) enables noninvasive carotid stenosis assessment and intraplaque neovascularization (IPN) grading for evaluating plaque vulnerability and stroke risk, but manual interpretation is time-consuming and expertise-dependent. We aimed to develop a deep learning (DL)-based automated method for stenosis assessment and IPN grading of carotid plaque from CEUS videos and to compare its performance with that of experienced radiologists.Methods: This multi-center study retrospectively collected CEUS videos from three tertiary hospitals between June 2019 and August 2023 and divided them into training and validation sets. An independent test set was retrospectively collected at XXX Hospital from January to December 2023. Stenosis degree was classified as mild (<50%), moderate (50%-70%), and severe (³70%), with CTA as the reference (n = 152). Ground-truth IPN grades were primarily established through consensus between two senior radiologists, with disagreements resolved by an arbitrator. All radiologists and the arbitrator were blinded to patient information. Performance metrics included the Dice coefficient, expected average overlap, accuracy, and weighted k coefficient.Findings: For three-class stenosis classification, the model achieved 96% accuracy (95% CI: 91%–99%) and weighted k = 0.87 (95% CI: 0.76–0.97), demonstrating strong concordance with CTA. For binary classification at the clinically significant threshold, performance improved to 98% accuracy (95% CI: 94%–99%) and weighted k = 0.93 (95% CI: 0.85–1.00), highlighting its clinical utility. For IPN grading, accuracies of 88% (95% CI: 81%–94%) and 84% (95% CI: 79%–87%) were achieved in the validation and independent test sets, respectively, indicating good generalizability. Compared with radiologists, the model increased efficiency more than 100-fold for stenosis assessment and ~2000-fold for IPN grading.Interpretation: The proposed DL framework enables accurate, consistent, and highly efficient stenosis assessment and IPN grading from CEUS videos, demonstrating radiologist-level performance and facilitating early screening in high-risk populations.
- 6 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDeep Learning for Stenosis Assessment and Intraplaque Neovascularization Grading in Carotid Artery Using Contrast-Enhanced Ultrasound Video
Background: Contrast-enhanced ultrasound (CEUS) enables noninvasive carotid stenosis assessment and intraplaque neovascularization (IPN) grading for evaluating plaque vulnerability and stroke risk, but manual interpretation is time-consuming and expertise-dependent. We aimed to develop a deep learning (DL)-based automated method for stenosis assessment and IPN grading of carotid plaque from CEUS videos and to compare its performance with that of experienced radiologists.Methods: This multi-center study retrospectively collected CEUS videos from three tertiary hospitals between June 2019 and August 2023 and divided them into training and validation sets. An independent test set was retrospectively collected at XXX Hospital from January to December 2023. Stenosis degree was classified as mild (<50%), moderate (50%-70%), and severe (³70%), with CTA as the reference (n = 152). Ground-truth IPN grades were primarily established through consensus between two senior radiologists, with disagreements resolved by an arbitrator. All radiologists and the arbitrator were blinded to patient information. Performance metrics included the Dice coefficient, expected average overlap, accuracy, and weighted k coefficient.Findings: For three-class stenosis classification, the model achieved 96% accuracy (95% CI: 91%–99%) and weighted k = 0.87 (95% CI: 0.76–0.97), demonstrating strong concordance with CTA. For binary classification at the clinically significant threshold, performance improved to 98% accuracy (95% CI: 94%–99%) and weighted k = 0.93 (95% CI: 0.85–1.00), highlighting its clinical utility. For IPN grading, accuracies of 88% (95% CI: 81%–94%) and 84% (95% CI: 79%–87%) were achieved in the validation and independent test sets, respectively, indicating good generalizability. Compared with radiologists, the model increased efficiency more than 100-fold for stenosis assessment and ~2000-fold for IPN grading.Interpretation: The proposed DL framework enables accurate, consistent, and highly efficient stenosis assessment and IPN grading from CEUS videos, demonstrating radiologist-level performance and facilitating early screening in high-risk populations.