Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gabor Orban has a total of 83 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Single-Die-Level MEMS Post-Processing for Prototyping CMOS-Based Neural Probes Combined with Optical Fibers for Optogenetic Neuromodulation

    by Gabor Orban, Alberto Perna, Matteo Vincenzi, Raffaele Adamo, Gian Nicola Angotzi, Luca Berdondini, João Filipe Ribeiro

    The integration of complementary metal–oxide–semiconductor (CMOS) and micro-electromechanical systems (MEMSs) technologies for miniaturized biosensor fabrication enables unprecedented spatiotemporal resolution in monitoring the bioelectrical activity of the nervous system. Wafer-level CMOS technology incurs high costs, but multi-project wafer (MPW) runs mitigate this by allowing multiple users to share a single wafer. Still, monolithic CMOS biosensors require specialized surface materials or device geometries incompatible with standard CMOS processes. Performing MEMS post-processing on the few square millimeters available in MPW dies remains a significant challenge. In this paper, we present a MEMS post-processing workflow tailored for CMOS dies that supports both surface material modification and layout shaping for intracortical biosensing applications. To address lithographic limitations on small substrates, we optimized spray-coating photolithography methods that suppress edge effects and enable reliable patterning and lift-off of diverse materials. We fabricated a needle-like, 512-channel simultaneous neural recording active pixel sensor (SiNAPS) technology based neural probe designed for integration with optical fibers for optogenetic studies. To mitigate photoelectric effects induced by light stimulation, we incorporated a photoelectric shield through simple modifications to the photolithography mask. Optical bench testing demonstrated >96% light-shielding effectiveness at 3 mW of light power applied directly to the probe electrodes. In vivo experiments confirmed the probe’s capability for high-resolution electrophysiological measurements.


  • Open Access

    ChroMOS: a “microwire-like” CMOS neural probe for chronic neural recordings in mice

    by João Filipe Ribeiro, Alberto Perna, Gabor Orban, Christine Stubbendorff, Raffaele Adamo, Matteo Vincenzi, Gian Nicola Angotzi, Luca Berdondini


  • Open Access

    High-density, Identified Cell Recordings from Motor Cortex of Awake Behaving Macaques using 1024-channel SiNAPS-NHP Probes

    by G.N. Angotzi, A.M.E. Baker, M. Vincenzi, G. Orban, J.F. Ribeiro, V. Tenorio, L. Berdondini, S. N. Baker

    Objective/Background: Acquiring bioelectric signals from many single neurons in primate brain remains challenging. Chronic implants offer a reasonable channel count (∼100) but sample only a small, fixed region of the cortex. Acutely inserted electrodes can sample from a wider region by making new penetrations each day. The aim of this study was to develop an active dense CMOS probe and experimental procedures to demonstrate acute large-scale single unit recordings from behaving monkeys. Methods: A single-shank CMOS probe was specifically designed for intracortical macaque recordings. The device is based on SiNAPS technology, with additional multiplexing circuits to minimize output lines. Synchronous sampling at 20 kHz/channel from >2k electrode-pixels is achieved with multiple probe systems. Experiments were performed in behaving macaques, achieving multiple day insertions in the motor cortex. Methods were developed to extract spontaneous spiking times of antidromically-identified neurons. Results: The probe (10.7 mm in length, 158 μm in width, 50 μm in thickness) provides a regular array of 1024 electrodes (14 × 14 μm 2 ) arranged in 4 columns with an interelectrode pitch of 30 μm. Dural penetration is eased by a small pilot hole; the optimized insertion procedure allows recordings from many different sites. Some cells were identified by antidromic activation as pyramidal tract neurons, which project to the spinal cord. Conclusion: This probe configuration can reach the anterior bank of the central sulcus, which contains many corticospinal cells that connect directly to motoneurons. Significance: This study is an important advance in the toolkit of primate neurophysiology.


  • Top Cited Papers
    Open Access

    Multi‐Shank 1024 Channels Active SiNAPS Probe for Large Multi‐Regional Topographical Electrophysiological Mapping of Neural Dynamics

    by Gian Nicola Angotzi, Mihály Vöröslakos, Nikolas Perentos, Joao Filipe Ribeiro, Matteo Vincenzi, Fabio Boi, Aziliz Lecomte, Gabor Orban, Andreas Genewsky, Gerrit Schwesig, et al.

    Implantable active dense CMOS neural probes unlock the possibility of spatiotemporally resolving the activity of hundreds of single neurons in multiple brain circuits to investigate brain dynamics. Mapping neural dynamics in brain circuits with anatomical structures spanning several millimeters, however, remains challenging. Here, a CMOS neural probe advancing lateral sampling for mapping intracortical neural dynamics (both LFPs and spikes) in awake, behaving mice from an area >4 mm2 is demonstrated. By taking advantage of SiNAPS technology modularity, an 8‐shank probe with 1024 recording channels arranged in regular arrays of 128 electrodes/shank with an electrode pitch RMS) from all 1024 electrodes at 20 kHz/channel demonstrate the monitoring at high spatial and temporal resolution of a field of view spanning the 2D lattice of the entire mice hippocampal circuit, together with cortical and thalamic regions. This arrangement allows combining large population unit monitoring across distributed networks with precise intra‐ and interlaminar/nuclear mapping of the oscillatory dynamics.


  • Open Access

    Force Measurements to Advance the Design and Implantation of CMOS-Based Neural Probes

    by Alberto Perna, Gabor Orban, Luca Berdondini, Joao F. Ribeiro

    Objective: Tissue penetrating active neural probes provide large and densely packed microelectrode arrays for the fine-grained investigation of brain circuits and for advancing brain-machine interfaces (BMIs). To improve the electrical interfacing performances of such stiff silicon devices, which typically elicit a vigorous foreign body reaction (FBR), here we perform insertion force measurements and derive probe layout and implantation procedure optimizations. Methods: We performed in-vivo insertion force measurements to evaluate the impact of probe design and implantation speed on mechanically induced trauma and iatrogenic injury. Because acute damage constitutes the initial trigger of FBR, these experiments allow to characterize and minimize device invasiveness. Results: Probe sharpness outweighs cross-sectional dimensions during the dimpling stage of the implantation, when the device compresses the brain before penetration. Insertion speed does not display a major effect on dimpling magnitude. A slow speed, however, significantly increases dimpling duration. Conclusion: It is crucial to use sharp devices to reduce mechanical and ischemic damage. Although slow insertion speeds typically improve the quality of acute electrophysiological recordings, we show that slow speeds should only be used upon penetration in the brain parenchyma and not during the dimpling stage. A closed-loop implantation procedure can be used to set the appropriate speed in the different insertion stages. Significance: We provide new evidence on the impact of probe layout and insertion speed on insertion force, with implications on the design and implantation procedure for minimally invasive CMOS neural probes. A novel closed-loop methodology to optimize device implantation and reduce FBR is proposed.


  • Open Access

    Multi-shank 1024 channels active SiNAPS probe for large multi-regional topographical electrophysiological mapping of neural dynamics

    by Luca Berdondini, Gian Nicola Angotzi, Mihaly Voroslakos, Nicholas Perentos, Joao Filipe Ribeiro, Matteo Vincenzi, Fabio Boi, Aziliz Lecomte, Gabor Orban, Andreas Genewsky, et al.

    Implantable active dense CMOS neural probes unlock the possibility of spatiotemporally resolving the activity of hundreds of single neurons in multiple brain circuits to investigate brain dynamics. Mapping neural dynamics in brain circuits with anatomical structures spanning several millimeters, however, remains challenging. Here, we demonstrate the first CMOS neural probe for mapping intracortical neural dynamics (both LFPs and spikes) in awake, behaving mice from an area >4 mm2. By taking advantage of the modularity of our SiNAPS technology, we realized an eight shanks probe with 1024 electrode channels arranged on each shank in regular arrays with an electrode pitch <30 μm. Low-noise recordings from all electrodes at 20 kHz/channel demonstrate a field of view spanning the 2D lattice of the entire mice hippocampal circuit, together with cortical and thalamic regions. This arrangement allows combining large population unit recording across distributed networks with precise intra- and interlaminar/nuclear mapping of the oscillatory dynamics.


  • Simultaneous high-density 512-channel SiNAPS electrical recordings and optogenetics

    by Gabor Orban, Alberto Perna, Matteo Vincenzi, Alessandro Caltabiano, Luca Nava, Raffaella Tonini, Gian Nicola Angotzi, João F. Ribeiro, Luca Berdondini

    The experimental use of CMOS high-density neural probes enables the wide field observation of the electrical activity of neural circuits at the resolution of single neurons. Optogenetic light stimulation allows to control and modulate the activity of neural cells, in a genetically selective manner. The combination of these techniques can be a powerful approach for investigating mechanisms of brain diseases and of information processing in the brain. The main obstacle to combining such techniques, however, is the photosensitivity of CMOS circuits and consequent photoelectric artefacts affecting electrophysiological recordings. This paper presents a CMOS based high-density SiNAPS neural implant which was designed to be combined with a tapered optical fiber. A photoelectric shield was created on a 512-channel probe, where the electrodes are arranged in 4 columns with 29.5 μm electrode pitch. Results show the light sensitivity of the probe with and without the photoelectric shield and the capability of recording light-evoked responses in vivo. More than 180 neurons were recorded without any light-induced distortion of the electrophysiological signals.


  • Impact of Tip Size and Shape on the Insertion Force of Implantable CMOS Neural Probes

    by Alberto Perna, João F. Ribeiro, Gabor Orban, Matteo Vincenzi, Fabio Boi, Gian N. Angotzi, Luca Berdondini

    Tissue penetrating neural probes implementing high-density microelectrode arrays constitute a key tool of modern neuroscience. One of the main limitations of current probes to achieve chronically stable intracortical neural interfacing, is the biological reaction that they onset in the brain. Such foreign body reaction (FBR) is initiated by the mechanical tissue damage that the probes cause during their insertion, which is expected to be correlated with the force required to perform the implantation. One potential strategy to improve the integration of tissue penetrating high-density neural probes within brain tissue is to optimize their size and geometry in order to minimize acute tissue damage and Blood Brain Barrier (BBB) disruption. This strategy is foreseen to yield a more favorable postsurgical environment, reducing the extent of FBR in a chronic setting. In this context, the force required for the insertion of tissue penetrating neural probes can be used as an objective metric to assess the extent of acute tissue damage they induce. This paper reports preliminary findings on the impact of Complementary Metal Oxide Semiconductor (CMOS) probe geometrical parameters on insertion force, with a particular focus on the importance of tip size and shape on the dimpling of brain tissue before penetration.


  • Channels, Layout and Size Scalability of Implantable CMOS-Based Multielectrode Array Probes

    by J.F. Ribeiro, G. Angotzi, A. Perna, M. Vincenzi, G. Orban, F. Boi, L. Berdondini

    Micro-structured monolithic CMOS devices enable the integration of dense microelectrode arrays and on-chip circuits for low-power implantable brain interfaces with single neuron spatiotemporal resolution. Here, we demonstrate the scalability of SiNAPS CMOS-probe technology with respect to different probe layouts, array sizes and shank dimensions down to microwire size ranges.