TTTannia Jazmín Vargas Tierra

Tannia Jazmín Vargas Tierra

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tannia Jazmín Vargas Tierra has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Manejo integrado de Rhipicephalus microplus: resistencia a acaricidas y estrategias biológicas en la Amazonía ecuatoriana

    by José Eduardo Zapata Gaibor, Tannia Jazmín Vargas Tierra, Vanessa Morales León, Sandra Isabel Castañeda Caguana

    La garrapata bovina Rhipicephalus microplus representa una limitante crítica para la producción ganadera en regiones tropicales, debido a su impacto sobre la salud animal y su papel como vector de enfermedades hemoparasitarias. El control tradicional se ha basado en el uso de acaricidas químicos; sin embargo, su aplicación intensiva ha favorecido la aparición de resistencia, reduciendo su eficacia. Esta revisión analiza la resistencia a ivermectina y cipermetrina en poblaciones de R. microplus de la Amazonía ecuatoriana, donde se evidencian variaciones en la susceptibilidad, con niveles de resistencia moderada y tolerancia emergente. Frente a esta problemática, se evalúan alternativas sostenibles como extractos vegetales y control biológico. Especies como Piper aduncum, Mansoa alliacea y Lonchocarpus nicou presentan actividad acaricida dependiente de la concentración, mientras que Beauveria bassiana muestra alta eficacia con mortalidades superiores al 90% en condiciones de laboratorio. La integración de estrategias químicas, botánicas y biológicas se plantea como una alternativa viable para reducir la presión de selección y mejorar la sostenibilidad del control de garrapatas en sistemas ganaderos tropicales.

  • Open Access

    Detection of arsenic and lead ions in water through validation of the electrothermal atomic absorption method

    by Tannia Vargas-Tierras, Vanessa Morales-León, Sharon Andi-Barrera, Rubén Toapanta-Topón, María Morales-León, Lissette Segovia-Tello, Viviana Lara-Villegas

    The validation of the electrothermal spectrometry method for Arsenic and lead determination in water samples guarantees the quality of analytical data. The study was carried out at AQLAB. A theoretical and technical investigation was applied to ensure the reliability and accuracy of the analytical method. Parameters such as INEN standards, Eurachem international standards, AQLAB internal documents and environmental standards were used to validate the process. Several readings were performed on different samples to make calibration curves for As and Pb, evaluate the method's linearity, and obtain information on the slope, intercept and determination coefficient. Statistical calculations were used to determine the limit of detection and quantification, repeatability, reproducibility, trueness and uncertainty. The results show that the hypotheses were fulfilled, calibration curves with determination coefficient higher than 0.995, repeatability standard deviation lower than 16%, calculated F < critical F (4.96), calculated t student < theoretical (2.23), trueness was between 100.29-110.18 and 99.64-107.92%, uncertainty was 20% range 0.005 to 0.10 mg/L and 15% range 0.01-0.20mg/L, limit of detection was 0.001 and 0.005 mg/L and limit of quantification was 0.01 and 0.02mg/L, respectively. Therefore, the validation method was robust and accurate.