Mohammed H. A. Alopaedy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohammed H. A. Alopaedy has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Alameer H Alhasan
University of Technology
1 shared publication Alameer H. Alhasan
College of Materials Engineering University of Technology Baghdad Iraq
1 shared publicationAli M Abd
Materials Research Centre Nanotechnology and Advanced University of Technology Baghdad Iraq
1 shared publication- Ali M Abd
University of Technology
1 shared publication Ghufran F. Hasan
Materials Research Centre Nanotechnology and Advanced University of Technology Baghdad Iraq
1 shared publication- Layth Al-Gebory
Department of Material Engineering, University of Technology, Baghdad, Iraq
1 shared publication
Latest Publications
- Open Access
- 1 June 2026
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 1644 (1)
Optimizing Graphene – Alumina Nanocomposite Coatings on Titanium Alloy via Spin Coating for Dual Corrosion Resistance and Antimicrobial Functionality in Dental Implants
Ti implants are susceptible to corrosion and colonize with microbes in the oral environment; thus, there is a demand for enhanced surface protection. The fabrication and characterization of a graphene–alumina (Gr–Al 2 O 3 ) nanocomposite coating on CP Ti by a large-scale production-compatible method of spin coating. Five composites were fabricated: C0 (uncoated Ti), C1 (Al 2 O 3 only), C2 (Al 2 O 3 + 0.5 wt% graphene), C3 (Al2O3 + 1.0 wt% graphene) and C4 (Al 2 O 3 + 2.0 wt% graphene). X-ray diffraction and scanning electron microscopy results suggested that the interfacial contact was enhanced, and there were fewer porosities with higher coated density after the addition of graphene. The electrochemical tests were conducted in simulated body fluid, revealing that the corrosion current of the nanocomposites with graphene was substantially reduced (C3: Icorr = 1.22 10 −7 A·cm −2 ), compared to that of the Al 2 O 3 -only coating (C1: Icorr = 1.74 × 10 −7 A·cm −2 ). Antimicrobial assay: disk diffusion tests revealed a dose-dependent bacterial inhibition, with the best inhibition shown by C4 (11.3 mm). These findings imply the synergetic effect between graphene acting as both a physical barrier and an antibacterial agent, as well as alumina strengthening the coating. The results indicate that overall, the developed graphene–alumina nanocomposite coating reveals good corrosion protection and antibacterial performance properties, which promote its further application as long-lasting and biocompatible dental-implants.
- 1 June 2026
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 1644 (1)
Open AccessOptimizing Graphene – Alumina Nanocomposite Coatings on Titanium Alloy via Spin Coating for Dual Corrosion Resistance and Antimicrobial Functionality in Dental Implants
Ti implants are susceptible to corrosion and colonize with microbes in the oral environment; thus, there is a demand for enhanced surface protection. The fabrication and characterization of a graphene–alumina (Gr–Al 2 O 3 ) nanocomposite coating on CP Ti by a large-scale production-compatible method of spin coating. Five composites were fabricated: C0 (uncoated Ti), C1 (Al 2 O 3 only), C2 (Al 2 O 3 + 0.5 wt% graphene), C3 (Al2O3 + 1.0 wt% graphene) and C4 (Al 2 O 3 + 2.0 wt% graphene). X-ray diffraction and scanning electron microscopy results suggested that the interfacial contact was enhanced, and there were fewer porosities with higher coated density after the addition of graphene. The electrochemical tests were conducted in simulated body fluid, revealing that the corrosion current of the nanocomposites with graphene was substantially reduced (C3: Icorr = 1.22 10 −7 A·cm −2 ), compared to that of the Al 2 O 3 -only coating (C1: Icorr = 1.74 × 10 −7 A·cm −2 ). Antimicrobial assay: disk diffusion tests revealed a dose-dependent bacterial inhibition, with the best inhibition shown by C4 (11.3 mm). These findings imply the synergetic effect between graphene acting as both a physical barrier and an antibacterial agent, as well as alumina strengthening the coating. The results indicate that overall, the developed graphene–alumina nanocomposite coating reveals good corrosion protection and antibacterial performance properties, which promote its further application as long-lasting and biocompatible dental-implants.
- Open Access
- 1 January 2026
- Published by MIM Research Group in Research on Engineering Structures and Materials
Enhancing the corrosion resistance and potential biomedical applications of titanium dental implants coated with niobium pentoxide
The excellent mechanical strength and clinical reliability of titanium-based implants are key advantages of their applications in biomedical fields. However, their susceptibility to bacterial colonization and corrosion remains a major limitation, affecting long-term performance and compromising patient safety. The present study described a niobium pentoxide coating, applied using the spin coating technique followed by thermal annealing, as a viable surface modification approach that can be used to enhance the corrosion resistance and antibacterial performance of titanium dental implants. The Nb₂O₅ suspension was prepared under controlled conditions and subsequently deposited, in multiple layers, onto the substrate to form a uniform protective film. Electrochemical characterization by potentiodynamic polarization (Tafel analysis) demonstrated a significant decrease in the corrosion rate, from 0.0077 mm/year for uncoated to 0.0021 mm/year for coated titanium, representing a ~73% decrease in corrosion current density. These results proved that a stable passive layer had formed, enhancing surface stability in physiological media. Successful crystallization of Nb₂O₅ phases upon thermal treatment, as confirmed by XRD analysis, accounted for the enhanced electrochemical performance. Antibacterial properties against Staphylococcus aureus ATCC 25923 were evaluated by the agar diffusion method. Results obtained showed that the diameter of the inhibition zone had increased from 12.9 ± 0.4 mm (uncoated) to 15.1 ± 0.5 mm (coated), corresponding to a statistically significant improvement of 16.7% (p < 0.05). Enhanced antibacterial properties were related to changes in surface properties owing to the deposition of Nb₂O₅ films, leading to reduced bacterial adhesion and biofilm growth. Conclusion The Nb₂O₅ coating contributed significantly to the improvement of corrosion resistance and the antibacterial properties of the titanium implants, hence demonstrating biomedical relevance for future applications in dentistry.
- 1 January 2026
- Published by MIM Research Group in Research on Engineering Structures and Materials
Open AccessEnhancing the corrosion resistance and potential biomedical applications of titanium dental implants coated with niobium pentoxide
The excellent mechanical strength and clinical reliability of titanium-based implants are key advantages of their applications in biomedical fields. However, their susceptibility to bacterial colonization and corrosion remains a major limitation, affecting long-term performance and compromising patient safety. The present study described a niobium pentoxide coating, applied using the spin coating technique followed by thermal annealing, as a viable surface modification approach that can be used to enhance the corrosion resistance and antibacterial performance of titanium dental implants. The Nb₂O₅ suspension was prepared under controlled conditions and subsequently deposited, in multiple layers, onto the substrate to form a uniform protective film. Electrochemical characterization by potentiodynamic polarization (Tafel analysis) demonstrated a significant decrease in the corrosion rate, from 0.0077 mm/year for uncoated to 0.0021 mm/year for coated titanium, representing a ~73% decrease in corrosion current density. These results proved that a stable passive layer had formed, enhancing surface stability in physiological media. Successful crystallization of Nb₂O₅ phases upon thermal treatment, as confirmed by XRD analysis, accounted for the enhanced electrochemical performance. Antibacterial properties against Staphylococcus aureus ATCC 25923 were evaluated by the agar diffusion method. Results obtained showed that the diameter of the inhibition zone had increased from 12.9 ± 0.4 mm (uncoated) to 15.1 ± 0.5 mm (coated), corresponding to a statistically significant improvement of 16.7% (p < 0.05). Enhanced antibacterial properties were related to changes in surface properties owing to the deposition of Nb₂O₅ films, leading to reduced bacterial adhesion and biofilm growth. Conclusion The Nb₂O₅ coating contributed significantly to the improvement of corrosion resistance and the antibacterial properties of the titanium implants, hence demonstrating biomedical relevance for future applications in dentistry.