Xiao-Gang Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiao-Gang Hu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Gang Li
1 shared publicationHong-Lai Jin
1 shared publication- Hongpeng Li
Department of Interventional Radiology, Jinhua Hospital of Zhejiang University School of Medicine, Jinhua City, Zhejiang, China
1 shared publication Jia-Min Wang
1 shared publication- Jiamin Wang
Department of Interventional Radiology, Jinhua Hospital of Zhejiang University School of Medicine, Jinhua City, Zhejiang, China
1 shared publication Jian-Ji Dai
1 shared publication
Latest Publications
- Open Access
- 1 July 2026
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 18 (7) , 760
Percutaneous mechanical thrombectomy using the AcoStream thrombus aspiration system for intermediate-high-risk pulmonary embolism
Background: Intermediate-high-risk pulmonary embolism (PE), characterized by right ventricular (RV) dysfunction and elevated cardiac biomarkers without hemodynamic instability, carries a substantial risk of clinical deterioration. While catheter-directed thrombolysis (CDT) is effective, it carries inherent bleeding risks. Large-bore mechanical thrombectomy (MT) has emerged as a promising alternative, but its real-world efficacy and safety require further validation. Therefore, we retrospectively reviewed consecutive patients with acute intermediate-high-risk PE who underwent MT using the AcoStream system. Methods: Between July 2021 and February 2025, 45 patients diagnosed with acute intermediate-high-risk PE who underwent MT using the AcoStream system were retrospectively analyzed. Efficacy outcomes included immediate and early improvements in the angiographic total Miller index, pulmonary artery systolic pressure (PASP), gas exchange (PaO2/FiO2 ratio), vital signs (heart rate), and tissue perfusion (lactate levels). Additionally, the post-procedural right ventricular/left ventricular (RV/LV) diameter ratio at 48 hours was evaluated. Safety outcomes included major bleeding and clinically relevant non-major bleeding (CRNMB) defined by the International Society on Thrombosis and Haemostasis (ISTH) criteria. Results: Following the procedure, the median total Miller index decreased significantly from 16.00 [interquartile range (IQR), 15.00, 18.00] to 6.00 (IQR, 5.00, 8.00) (PConclusions: MT using the AcoStream system was associated with favorable short-term procedural and hemodynamic observations in patients with acute intermediate-high-risk PE. Given the observational design and lack of a comparator group, these findings should be considered hypothesis-generating and require confirmation in larger prospective studies.
- 1 July 2026
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 18 (7) , 760
Open AccessPercutaneous mechanical thrombectomy using the AcoStream thrombus aspiration system for intermediate-high-risk pulmonary embolism
Background: Intermediate-high-risk pulmonary embolism (PE), characterized by right ventricular (RV) dysfunction and elevated cardiac biomarkers without hemodynamic instability, carries a substantial risk of clinical deterioration. While catheter-directed thrombolysis (CDT) is effective, it carries inherent bleeding risks. Large-bore mechanical thrombectomy (MT) has emerged as a promising alternative, but its real-world efficacy and safety require further validation. Therefore, we retrospectively reviewed consecutive patients with acute intermediate-high-risk PE who underwent MT using the AcoStream system. Methods: Between July 2021 and February 2025, 45 patients diagnosed with acute intermediate-high-risk PE who underwent MT using the AcoStream system were retrospectively analyzed. Efficacy outcomes included immediate and early improvements in the angiographic total Miller index, pulmonary artery systolic pressure (PASP), gas exchange (PaO2/FiO2 ratio), vital signs (heart rate), and tissue perfusion (lactate levels). Additionally, the post-procedural right ventricular/left ventricular (RV/LV) diameter ratio at 48 hours was evaluated. Safety outcomes included major bleeding and clinically relevant non-major bleeding (CRNMB) defined by the International Society on Thrombosis and Haemostasis (ISTH) criteria. Results: Following the procedure, the median total Miller index decreased significantly from 16.00 [interquartile range (IQR), 15.00, 18.00] to 6.00 (IQR, 5.00, 8.00) (PConclusions: MT using the AcoStream system was associated with favorable short-term procedural and hemodynamic observations in patients with acute intermediate-high-risk PE. Given the observational design and lack of a comparator group, these findings should be considered hypothesis-generating and require confirmation in larger prospective studies.
- Open Access
- 16 January 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (3) , e46945
Navigating the challenge – endovascular embolization of a giant bronchial artery aneurysm with a short, irregular neck: A case report
Rationale: Bronchial artery aneurysm (BAA) is a rare condition, but it can be life-threatening if the aneurysm ruptures. While endovascular therapy is the primary treatment, the selection of embolic material is limited by the tortuous and short aneurysm neck. Patient concerns: We report a huge, suspected ruptured BAA was unexpectedly detected in a 69-year-old man during a routine medical examination. Diagnoses: Enhanced chest computed tomography angiography and selective bronchial arteriography both revealed that the BAA was located at the proximal portion of the left bronchial artery It was characterized by a large aneurysm sac and a short, irregularly dilated aneurysm neck. Interventions: We successfully occluded the huge BAA using a single amplatzer vascular plug. Outcomes: The 6-month computed tomography angiography follow-up scan showed no signs of aneurysm recurrence. Lessons: Transcatheter embolization utilizing a single amplatzer vascular plug has proven to be an effective and cost-efficient treatment for BAAs that are characterized by a large aneurysm sac and a short, tortuous, irregularly dilated aneurysm neck.
- 16 January 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (3) , e46945
Open AccessNavigating the challenge – endovascular embolization of a giant bronchial artery aneurysm with a short, irregular neck: A case report
Rationale: Bronchial artery aneurysm (BAA) is a rare condition, but it can be life-threatening if the aneurysm ruptures. While endovascular therapy is the primary treatment, the selection of embolic material is limited by the tortuous and short aneurysm neck. Patient concerns: We report a huge, suspected ruptured BAA was unexpectedly detected in a 69-year-old man during a routine medical examination. Diagnoses: Enhanced chest computed tomography angiography and selective bronchial arteriography both revealed that the BAA was located at the proximal portion of the left bronchial artery It was characterized by a large aneurysm sac and a short, irregularly dilated aneurysm neck. Interventions: We successfully occluded the huge BAA using a single amplatzer vascular plug. Outcomes: The 6-month computed tomography angiography follow-up scan showed no signs of aneurysm recurrence. Lessons: Transcatheter embolization utilizing a single amplatzer vascular plug has proven to be an effective and cost-efficient treatment for BAAs that are characterized by a large aneurysm sac and a short, tortuous, irregularly dilated aneurysm neck.