Hejuan Du
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hejuan Du has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Dawa Drolma
NMPA key Laboratory for Quality Control of Traditional Chinese Medicine, Tibetan Medicine, Xizang Institute for Food and Drug Control, Lhasa 850000, China
1 shared publication - Jiaguo Li
Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China
1 shared publication - Jun Liu
Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China
1 shared publication - Limin Zhao
Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China
1 shared publication - Shihao Xie
Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China
1 shared publication - Tingting Shi
State Key Laboratory Breeding Base of Dao-di Herbs, National Resource Center for Chinese Materia Medica, Chinese Academy of Chinese Medical Sciences, Beijing 100700, China
1 shared publication
Latest Publications
- Open Access
Selection of Specimen Orientations for Hyperspectral Identification of Wild and Cultivated Ophiocordyceps sinensis
Ophiocordyceps sinensis is a precious medicinal material with significant pharmacological and economic value. However, the visual similarity between its wild and cultivated forms poses a challenge for authentication. This study investigates the influence of specimen orientation on the accuracy of hyperspectral identification. Hyperspectral data were systematically acquired from four standard specimen orientations (left lateral, right lateral, dorsal, and ventral) for each sample. Random Forest (RF), Support Vector Machine (SVM), Logistic Regression (LR), and Fully Connected Neural Network (FCNN) models were trained and evaluated using both single-orientation and multi-orientation fused data. Results indicate that the LR model achieved superior and stable performance, with an average identification accuracy exceeding 98%. Crucially, for all tested models, no statistically significant difference in identification accuracy was observed across the different specimen orientations. This finding demonstrates that specimen orientation does not significantly influence identification accuracy. The conclusion was further corroborated in experiments using randomly orientation-fused datasets, in which model performance remained consistent and reliable. It is therefore concluded that precise specimen orientation control is unnecessary for the hyperspectral identification of Ophiocordyceps sinensis. This insight substantially simplifies the hardware design of dedicated identification devices by eliminating the need for complex orientation-fixing mechanisms and facilitating the standardization of operational protocols. The study provides a practical theoretical foundation for developing cost-effective, user-friendly, and widely applicable identification instruments for Ophiocordyceps sinensis and offers a reference for similar non-destructive testing applications involving anisotropic medicinal materials.
Open AccessSelection of Specimen Orientations for Hyperspectral Identification of Wild and Cultivated Ophiocordyceps sinensis
Ophiocordyceps sinensis is a precious medicinal material with significant pharmacological and economic value. However, the visual similarity between its wild and cultivated forms poses a challenge for authentication. This study investigates the influence of specimen orientation on the accuracy of hyperspectral identification. Hyperspectral data were systematically acquired from four standard specimen orientations (left lateral, right lateral, dorsal, and ventral) for each sample. Random Forest (RF), Support Vector Machine (SVM), Logistic Regression (LR), and Fully Connected Neural Network (FCNN) models were trained and evaluated using both single-orientation and multi-orientation fused data. Results indicate that the LR model achieved superior and stable performance, with an average identification accuracy exceeding 98%. Crucially, for all tested models, no statistically significant difference in identification accuracy was observed across the different specimen orientations. This finding demonstrates that specimen orientation does not significantly influence identification accuracy. The conclusion was further corroborated in experiments using randomly orientation-fused datasets, in which model performance remained consistent and reliable. It is therefore concluded that precise specimen orientation control is unnecessary for the hyperspectral identification of Ophiocordyceps sinensis. This insight substantially simplifies the hardware design of dedicated identification devices by eliminating the need for complex orientation-fixing mechanisms and facilitating the standardization of operational protocols. The study provides a practical theoretical foundation for developing cost-effective, user-friendly, and widely applicable identification instruments for Ophiocordyceps sinensis and offers a reference for similar non-destructive testing applications involving anisotropic medicinal materials.