Ahmed Al Faraj
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ahmed Al Faraj has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Alejandro Cohen
Proteomics Core Facility, Life Sciences Research Institute, Dalhousie University, Halifax, Canada
1 shared publication - Luke K. Wiseman
Department of Anesthesia, Pain Management and Perioperative Medicine , Dalhousie University , Halifax , NS , Canada
1 shared publication - Pantelis Andreou
Department of Community Health and Epidemiology (S.K.L., A.S.C., P.A., L.E.C.), Dalhousie University, Halifax, Nova Scotia, Canada
1 shared publication - Richard Hall
Department of Anesthesia, Pain Management and Perioperative Medicine , Dalhousie University , Halifax , NS , Canada
1 shared publication - Victor M. Neira
Victor M. Neira, M.D. M.A.Ed., and Robyn Doucet, M.D., M.M.Ed.: Department of Anesthesia, Perioperative Medicine, and Pain Management, Dalhousie University, Halifax, Nova Scotia, Canada
1 shared publication
Latest Publications
- Open Access
- 1 January 2023
- Published by Walter de Gruyter GmbH in Pharmaceutical Technology in Hospital Pharmacy
- Vol. 8 (1)
Use of a liquid chromatography-tandem mass spectrometry method to assess the concentration of epinephrine, norepinephrine, and phenylephrine stored in plastic syringes
Objectives: There are concerns about the potency of epinephrine (EPI), norepinephrine (NE), and phenylephrine (PE) stored in syringes for later infusions in clinical care. The objective of our study was to optimize a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to determine the concentrations EPI, NE, and PE dissolved in normal saline and stored in 50 mL 3-part Becton Dickinson syringes. Methods: Medications were diluted in normal saline to 80 μg/mL for EPI and NE, and 100 μg/mL for PE. The solutions were stored in syringes for 0 (fresh), 3, and 7 days in a medical refrigerator. United States Pharmacopeia grade EPI, NE, and PE and their deuterium-labeled analogs were used as calibration standards. Stored samples and standards were diluted and analyzed by LC-MS/MS operated in selected reaction monitoring mode. Results: The calculated limit of quantification for EPI, NE and PE were well below the concentrations used in clinical practice. The coefficient of variation remained below 12 % for all samples. The standard linear calibration regressions for EPI, NE, and PE had r 2 values of between 0.96 and 0.98 (p < 0.001). EPI and NE stored in the refrigerator remained within 10 % of the of their initial concentrations at all time points. The concentration of PE in syringe decreased by 19.85 % at 3 days, with no further decrease at 7 days, compared to fresh PE. Conclusions: The sample preparation steps and optimized LC-MS/MS method allowed simple and reliable measurements of EPI, NE, and PE.
- 1 January 2023
- Published by Walter de Gruyter GmbH in Pharmaceutical Technology in Hospital Pharmacy
- Vol. 8 (1)
Open AccessUse of a liquid chromatography-tandem mass spectrometry method to assess the concentration of epinephrine, norepinephrine, and phenylephrine stored in plastic syringes
Objectives: There are concerns about the potency of epinephrine (EPI), norepinephrine (NE), and phenylephrine (PE) stored in syringes for later infusions in clinical care. The objective of our study was to optimize a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to determine the concentrations EPI, NE, and PE dissolved in normal saline and stored in 50 mL 3-part Becton Dickinson syringes. Methods: Medications were diluted in normal saline to 80 μg/mL for EPI and NE, and 100 μg/mL for PE. The solutions were stored in syringes for 0 (fresh), 3, and 7 days in a medical refrigerator. United States Pharmacopeia grade EPI, NE, and PE and their deuterium-labeled analogs were used as calibration standards. Stored samples and standards were diluted and analyzed by LC-MS/MS operated in selected reaction monitoring mode. Results: The calculated limit of quantification for EPI, NE and PE were well below the concentrations used in clinical practice. The coefficient of variation remained below 12 % for all samples. The standard linear calibration regressions for EPI, NE, and PE had r 2 values of between 0.96 and 0.98 (p < 0.001). EPI and NE stored in the refrigerator remained within 10 % of the of their initial concentrations at all time points. The concentration of PE in syringe decreased by 19.85 % at 3 days, with no further decrease at 7 days, compared to fresh PE. Conclusions: The sample preparation steps and optimized LC-MS/MS method allowed simple and reliable measurements of EPI, NE, and PE.