VPV.O. Putienko

V.O. Putienko

*This is an algorithmically generated author record based on publicly available information.

V.O. Putienko has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Results of vitreoretinal surgery for eye injuries caused by thermally altered plastics used in 3D printing of strike drones

    by D.M. Pohorilyy, O.O. Putiienko, M.H. Lysenko, L.L. Davtian, V.O. Putienko

    Background. Over the past two years of war, various FPV drones have become the most common type of weapon used against military personnel. This has led to the emergence of a new class of intraocular foreign bodies (IOFB) — thermally altered plastics used in 3D printing of strike drones. Currently, there is a need to study the characteristics of this type of trauma, clarify the terms and scope of surgical treatment and methods to remove such IOFB. The purpose of the study was to examine the results of vitreoretinal surgery for injuries caused by a new class of intraocular foreign bo­dies — thermally altered plastics used in 3D printing of strike drones. Materials and methods. Eighteen military personnel (22 eyes) with penetrating eye injuries resulting from FPV drone strikes were observed. In 14 cases, one eye was injured, and in four cases, both eyes were injured. Multiple foreign bodies were present in 12 eyes. There were 11 eyes with zone I damage, 4 eyes with zone II damage, and 7 eyes with zone III damage. Vitrectomy was performed with a 25 or 23G caliber, with phacoemulsification and IOFB removal using forceps or a vitreous probe as necessary. The operation was completed on 4 eyes without tamponade, in 8 cases with tamponade with a 20% gas-air mixture C3F8, and in 10 cases with silicone oil. The observation period was 2 months. Results. In eyes with zone I damage, corneal opacity was observed in all cases, in 3 eyes in the optical zone with a diameter of 3–6 mm. All eyes were artificial, intraocular pressure (IOP) was within normal limits, and the iris was altered in 7 eyes. The retina was adjacent in all cases with a normal optic nerve. In zone II damage, IOP was within normal limits in all cases. In the zones of IOFB removal, there were chorioretinal foci, and macular damage was observed in one case with severe retinal thinning. The optic nerve was also unchanged. In eyes with zone III damage, the retina was adjacent in 5 cases, and in 2 eyes, retinal detachment was observed under silicone oil tamponade. All eyes were artificial. IOP in two eyes with silicone tamponade was compensated with medication, in 3 eyes it was normal, and in 2 eyes it was below normal. Significant changes in the retina were observed (thinning in the macular area — 2 eyes, formation of epiretinal membranes — 2 eyes), as well as changes in the optic nerve (partial atrophy — 4 eyes). Conclusions. Vitreoretinal surgery to remove IOFB — thermally altered plastics used in 3D printing of strike drones — is highly effective with stable anatomical results in all areas of damage and a significant improvement in visual acuity. Thermally altered plastics in the eye mimic metal fragments according to computed tomography data, which requires improvement of the method or computed tomography itself, or the development of new diagnostic techniques in such cases. Damage caused by thermally altered plastics is not accompanied by the development of endophthalmitis. Further observation is necessary to determine in more detail the possible toxic effects of these IOFB and the results of vitreoretinal surgery to remove them.