Lu Wang
Research Subjects
Lu Wang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Chenlong Qian
School of Mines, China University of Mining and Technology, Xuzhou 221116, China
1 shared publication - Jinming Li
Shaanxi Shanmei Caojiatan Min Co., Ltd., Yulin 718000, China
1 shared publication - Lei Zhang
School of Mines, China University of Mining and Technology, Xuzhou 221116, China
1 shared publication - Shenxiang Gao
XuZhou China Mining Geotechnical Technology Co., Ltd., Xuzhou 221000, China
1 shared publication - Xufeng Wang
School of Mines, China University of Mining and Technology, Xuzhou 221116, China
1 shared publication - Zehui Wu
XuZhou China Mining Geotechnical Technology Co., Ltd., Xuzhou 221000, China
1 shared publication
Latest Publications
- Open Access
Study on Combined Protection Technology of Reinforcement and Rectification for High Voltage Tower on Super Large Mining Height of Mining-Induced Surface
Severe surface deformation induced by super-large mining height longwall extraction poses a significant threat to the safe operation of high-voltage transmission towers. In this study, a 330 kV straight-line transmission tower located above the 122104 working face of the Caojiatan Coal Mine was selected as a case study to investigate tower stability under mining-induced surface deformation and to develop corresponding protection technologies. An integrated monitoring system combining instantaneous and long-term measurements was established to characterize surface movement throughout the mining process. The results indicate that the maximum surface subsidence reached 7300 mm, while the maximum inclination and curvature attained 50 mm/m and 0.62 mm/m2, respectively, reflecting intense deformation of the overlying ground. Numerical simulations based on ANSYS 2021R1 were conducted to systematically evaluate the effects of surface inclination, compressive deformation, and tensile deformation on the structural response of the transmission tower. The critical deformation thresholds leading to structural failure were identified as 30 mm/m for inclination, −7.2 mm/m for horizontal compression, and 7.7 mm/m for horizontal tension. Based on these findings, a comprehensive protection system was proposed, integrating tower body reinforcement, combined foundation reconstruction, surface subsidence monitoring, dynamic jacking-based rectification, and foundation grouting reinforcement. The proposed scheme was successfully implemented in field practice. Monitoring results demonstrate that, after reinforcement and rectification, differential settlement of the tower foundation was controlled within 20 mm, and tower inclination remained below 1‰. This ensured uninterrupted underground mining operations and continuous power transmission within the Caojiatan Coal Mine corridor. The outcomes of this study provide a practical reference for the protection of high-voltage transmission towers under similar mining conditions.
Open AccessStudy on Combined Protection Technology of Reinforcement and Rectification for High Voltage Tower on Super Large Mining Height of Mining-Induced Surface
Severe surface deformation induced by super-large mining height longwall extraction poses a significant threat to the safe operation of high-voltage transmission towers. In this study, a 330 kV straight-line transmission tower located above the 122104 working face of the Caojiatan Coal Mine was selected as a case study to investigate tower stability under mining-induced surface deformation and to develop corresponding protection technologies. An integrated monitoring system combining instantaneous and long-term measurements was established to characterize surface movement throughout the mining process. The results indicate that the maximum surface subsidence reached 7300 mm, while the maximum inclination and curvature attained 50 mm/m and 0.62 mm/m2, respectively, reflecting intense deformation of the overlying ground. Numerical simulations based on ANSYS 2021R1 were conducted to systematically evaluate the effects of surface inclination, compressive deformation, and tensile deformation on the structural response of the transmission tower. The critical deformation thresholds leading to structural failure were identified as 30 mm/m for inclination, −7.2 mm/m for horizontal compression, and 7.7 mm/m for horizontal tension. Based on these findings, a comprehensive protection system was proposed, integrating tower body reinforcement, combined foundation reconstruction, surface subsidence monitoring, dynamic jacking-based rectification, and foundation grouting reinforcement. The proposed scheme was successfully implemented in field practice. Monitoring results demonstrate that, after reinforcement and rectification, differential settlement of the tower foundation was controlled within 20 mm, and tower inclination remained below 1‰. This ensured uninterrupted underground mining operations and continuous power transmission within the Caojiatan Coal Mine corridor. The outcomes of this study provide a practical reference for the protection of high-voltage transmission towers under similar mining conditions.