Nandini S. Gummalla
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nandini S. Gummalla has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Andrew T. Bender
Department of Mechanical Engineering, University of Washington, Stevens Way, Box 352600, Seattle, Washington, 98195, USA
2 shared publications - Coleman D. Martin
Department of Chemical Engineering, University of Washington, Seattle, Washington, USA
2 shared publications - Jonathan D. Posner
Department of Chemical Engineering, University of Washington, Seattle, Washington, USA
2 shared publications - Kelli N. Shimazu
Department of Mechanical Engineering, University of Washington, Stevens Way, Box 352600, Seattle, Washington, 98195, USA
2 shared publications
Latest Publications
- Open Access
- 18 September 2026
- Published by Royal Society of Chemistry (RSC) in Sensors & Diagnostics
- Vol. 5 (9) , 1144-1155
PEG-mediated viscous crowding controls dynamics and quantitative range in recombinase polymerase amplification nucleation site analysis
PEG-tuned viscous crowding enables compartment-free digital RPA with four-log absolute quantification in a simple microfluidic chip.
- 18 September 2026
- Published by Royal Society of Chemistry (RSC) in Sensors & Diagnostics
- Vol. 5 (9) , 1144-1155
Open AccessPEG-mediated viscous crowding controls dynamics and quantitative range in recombinase polymerase amplification nucleation site analysis
PEG-tuned viscous crowding enables compartment-free digital RPA with four-log absolute quantification in a simple microfluidic chip.
- 21 January 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (4) , 2797-2806
Extraction-Free Scalable Sample Preparation for the Rapid Detection of HIV in Blood Plasma
Nucleic acid amplification tests that are rapid and low-cost are needed for expanding access to point-of-care (POC) diagnostics for infectious diseases and viral load monitoring. Several companies have commercialized POC devices using rapid isothermal amplification; however, these tests use nasal swabs or saliva samples. Translating these tests to blood plasma is challenging due to clotting factors, heat- or pH-induced coagulation of human albumin, high concentrations of ribonucleases (RNases), and other sample matrix inhibitors. Crude, extraction-free sample preparation methods are promising alternatives that reduce the complexity of sample preparation. In this paper, we present an extraction-free sample preparation method for in-tube and paper-based reverse transcription recombinase polymerase amplification for the detection of HIV in blood plasma samples. We use a rapid heat treatment protocol with a reducing agent to inhibit RNases and lyse HIV virus, enabling RNA preservation into direct amplification without the need for complex RNA purification steps. We demonstrate sample treatment in 5 min and amplification within 20 min in reaction volumes ranging from 50 to 300 μL and show that large volume reactions achieve a limit of detection of 800 copies/mL (16 copies/reaction) for HIV-positive plasma in both paper and tube formats.
- 21 January 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (4) , 2797-2806
Extraction-Free Scalable Sample Preparation for the Rapid Detection of HIV in Blood Plasma
Nucleic acid amplification tests that are rapid and low-cost are needed for expanding access to point-of-care (POC) diagnostics for infectious diseases and viral load monitoring. Several companies have commercialized POC devices using rapid isothermal amplification; however, these tests use nasal swabs or saliva samples. Translating these tests to blood plasma is challenging due to clotting factors, heat- or pH-induced coagulation of human albumin, high concentrations of ribonucleases (RNases), and other sample matrix inhibitors. Crude, extraction-free sample preparation methods are promising alternatives that reduce the complexity of sample preparation. In this paper, we present an extraction-free sample preparation method for in-tube and paper-based reverse transcription recombinase polymerase amplification for the detection of HIV in blood plasma samples. We use a rapid heat treatment protocol with a reducing agent to inhibit RNases and lyse HIV virus, enabling RNA preservation into direct amplification without the need for complex RNA purification steps. We demonstrate sample treatment in 5 min and amplification within 20 min in reaction volumes ranging from 50 to 300 μL and show that large volume reactions achieve a limit of detection of 800 copies/mL (16 copies/reaction) for HIV-positive plasma in both paper and tube formats.