Marie Maigné
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marie Maigné has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Anne Olivier
CHU Angers, Service d’Hépato-gastro-entérologie, Angers, France
1 shared publication - Anne Rullier
Service de Pathologie, Place Amélie Rabat-Léon, CHU Bordeaux, Bordeaux, France
1 shared publication - Antoine Bénard
Clinical Epidemiology Unit (USMR), Pôle de Santé Publique, Centre Hospitalier Universitaire de Bordeaux, F-33076 Bordeaux, France
1 shared publication - Antoine Guilloux
Centre d’Endoscopie Digestive, Hôpital Saint-Antoine AP-HP, Sorbonne Université, Paris, France
1 shared publication - Arthur Berger
Gastroenterology and Endoscopy Unit, University hospital Bordeaux, Bordeaux, France
1 shared publication - Denis Smith
Hôpital Saint André, Bordeaux, France
1 shared publication
Latest Publications
- Open Access
- 21 January 2026
- Published by Wolters Kluwer Health in Clinical and Translational Gastroenterology
- Vol. 17 (3) , e00976
Real-Time Characterization of Colonic Polyps: A Multicenter Prospective Study Evaluating the CAD-EYE System in Screening Colonoscopies
INTRODUCTION: Polypectomy-related costs could potentially be reduced through optical diagnosis strategies, such as “diagnose-and-leave” and “resect-and-discard.” Artificial intelligence, using computer-aided diagnosis (CAD), may provide a reproducible optical diagnosis of colorectal lesions. This study aimed to assess the performance of the CAD-EYE system in the real-time characterization of colonic polyps. METHODS: We conducted a cross-sectional, multicenter study evaluating the CAD-EYE system in patients undergoing screening colonoscopies at 5 French centers. CAD-EYE predictions and assessments by endoscopists (hyperplastic vs neoplastic) were compared with histopathology results. The primary outcome was the sensitivity of CAD-EYE for predicting neoplastic polyps, compared with the predefined threshold of 85%. The secondary outcomes were the specificity, positive predictive value, negative predictive value, endoscopists' performance, and polyp detection rates. RESULTS: Of 398 polyps analyzed, 343 were included in the primary analysis. CAD-EYE characterization was feasible in 96% of cases. The sensitivity was 0.80 (95% confidence interval, 0.74–0.85), which failed to achieve the predefined threshold of 85% ( P = 0.064). The specificity, negative predictive value, and positive predictive value were 0.79, 0.64, and 0.90, respectively. Performance was higher for diminutive rectosigmoid polyps (DRSPs). Endoscopists showed higher sensitivity than CAD-EYE (0.90 vs 0.80, P = 0.001). CAD-EYE-assisted colonoscopies detected more polyps per procedure (3.3 vs 2.3, P < 0.001) than endoscopists alone. DISCUSSION: The performance of CAD-EYE was insufficient for the characterization of neoplastic colonic polyps. CAD-EYE performed better for DRSPs. AI seems to be beneficial for polyp detection.
- 21 January 2026
- Published by Wolters Kluwer Health in Clinical and Translational Gastroenterology
- Vol. 17 (3) , e00976
Open AccessReal-Time Characterization of Colonic Polyps: A Multicenter Prospective Study Evaluating the CAD-EYE System in Screening Colonoscopies
INTRODUCTION: Polypectomy-related costs could potentially be reduced through optical diagnosis strategies, such as “diagnose-and-leave” and “resect-and-discard.” Artificial intelligence, using computer-aided diagnosis (CAD), may provide a reproducible optical diagnosis of colorectal lesions. This study aimed to assess the performance of the CAD-EYE system in the real-time characterization of colonic polyps. METHODS: We conducted a cross-sectional, multicenter study evaluating the CAD-EYE system in patients undergoing screening colonoscopies at 5 French centers. CAD-EYE predictions and assessments by endoscopists (hyperplastic vs neoplastic) were compared with histopathology results. The primary outcome was the sensitivity of CAD-EYE for predicting neoplastic polyps, compared with the predefined threshold of 85%. The secondary outcomes were the specificity, positive predictive value, negative predictive value, endoscopists' performance, and polyp detection rates. RESULTS: Of 398 polyps analyzed, 343 were included in the primary analysis. CAD-EYE characterization was feasible in 96% of cases. The sensitivity was 0.80 (95% confidence interval, 0.74–0.85), which failed to achieve the predefined threshold of 85% ( P = 0.064). The specificity, negative predictive value, and positive predictive value were 0.79, 0.64, and 0.90, respectively. Performance was higher for diminutive rectosigmoid polyps (DRSPs). Endoscopists showed higher sensitivity than CAD-EYE (0.90 vs 0.80, P = 0.001). CAD-EYE-assisted colonoscopies detected more polyps per procedure (3.3 vs 2.3, P < 0.001) than endoscopists alone. DISCUSSION: The performance of CAD-EYE was insufficient for the characterization of neoplastic colonic polyps. CAD-EYE performed better for DRSPs. AI seems to be beneficial for polyp detection.