Annika Hofmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Annika Hofmann has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Florian Knoll
Department Artificial Intelligence in Biomedical Engineering Friedrich‐Alexander‐Universität Erlangen‐Nürnberg Erlangen Germany
3 shared publications - Frederik Bernd Laun
Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), 91054 Erlangen, Germany
3 shared publications - Julius Glaser
Institute of Radiology, University Hospital Erlangen, Friedrich‐Alexander‐University Erlangen‐Nürnberg (FAU) Erlangen Germany
2 shared publications - Patrick Liebig
Siemens Healthineers AG Erlangen Germany
2 shared publications - Zhengguo Tan
Michigan Institute for Imaging Technology and Translation (MIITT), Radiology, University of Michigan Ann Arbor Michigan USA
2 shared publications - Alexander German
Institute of Neuroradiology, University Hospital Erlangen, Friedrich‐Alexander‐University Erlangen‐Nürnberg (FAU) Erlangen Germany
1 shared publication
Latest Publications
- Open Access
- 22 October 2026
- Published by Wiley in Magnetic Resonance in Medicine
Toward Brain Biosignature at 7 T —Repeatability of a Multiparametric CEST , QSM , QTI , and Sodium Imaging Protocol
Purpose: To evaluate the repeatability of an extended multiparametric 7 T MRI protocol for voxel‐wise tissue characterization combining morphological, CEST, QSM, QTI, and Sodium contrasts. Methods: A repeatability study was performed in 12 volunteers without diagnosed neurological disease on a 7 T MRI system, using a comprehensive acquisition protocol with a combined acquisition time of 45:24 min, from which 45 contrast maps were derived. Quantitative repeatability was assessed using region‐based and voxel‐wise analyses. Precision and reliability were evaluated using the coefficient of variation (CV), repeatability coefficient (%RC), and intraclass correlation coefficient (ICC). Voxel‐wise agreement between scan–rescan images was assessed using Pearson correlation coefficients. Results: Across contrasts spanning morphological, CEST, QSM, QTI, and 23 Na imaging, %RC was below 20% for 20 contrasts, with mean CV below 5% for most. Repeatability was highest for MP2RAGE T 1 maps and QTI MD (CV ≈ 1%–2%; ICC up to 0.86) and lowest for 23 Na imaging (ICC < 0.6). CEST contrasts were highly repeatable at low saturation power but more variable at higher power (CV up to ≈8%). QSM contrasts showed moderate ICC (0.46–0.82). Voxel‐wise correlations exceeded r = 0.8 for most contrasts, confirming preserved spatial patterns across repeated scans. Conclusion: Multiparametric 7 T MRI enables reproducible voxel‐wise characterization of brain tissue across a wide range of contrasts. Despite variability in specific contrasts, the overall high repeatability and strong voxel‐wise agreement support the feasibility of voxel‐wise imaging approaches for quantitative brain imaging and provide a foundation for future applications in clinical research and neuroscience.
- 22 October 2026
- Published by Wiley in Magnetic Resonance in Medicine
Open AccessToward Brain Biosignature at 7 T —Repeatability of a Multiparametric CEST , QSM , QTI , and Sodium Imaging Protocol
Purpose: To evaluate the repeatability of an extended multiparametric 7 T MRI protocol for voxel‐wise tissue characterization combining morphological, CEST, QSM, QTI, and Sodium contrasts. Methods: A repeatability study was performed in 12 volunteers without diagnosed neurological disease on a 7 T MRI system, using a comprehensive acquisition protocol with a combined acquisition time of 45:24 min, from which 45 contrast maps were derived. Quantitative repeatability was assessed using region‐based and voxel‐wise analyses. Precision and reliability were evaluated using the coefficient of variation (CV), repeatability coefficient (%RC), and intraclass correlation coefficient (ICC). Voxel‐wise agreement between scan–rescan images was assessed using Pearson correlation coefficients. Results: Across contrasts spanning morphological, CEST, QSM, QTI, and 23 Na imaging, %RC was below 20% for 20 contrasts, with mean CV below 5% for most. Repeatability was highest for MP2RAGE T 1 maps and QTI MD (CV ≈ 1%–2%; ICC up to 0.86) and lowest for 23 Na imaging (ICC < 0.6). CEST contrasts were highly repeatable at low saturation power but more variable at higher power (CV up to ≈8%). QSM contrasts showed moderate ICC (0.46–0.82). Voxel‐wise correlations exceeded r = 0.8 for most contrasts, confirming preserved spatial patterns across repeated scans. Conclusion: Multiparametric 7 T MRI enables reproducible voxel‐wise characterization of brain tissue across a wide range of contrasts. Despite variability in specific contrasts, the overall high repeatability and strong voxel‐wise agreement support the feasibility of voxel‐wise imaging approaches for quantitative brain imaging and provide a foundation for future applications in clinical research and neuroscience.
- Open Access
- 4 August 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (5) , 2359-2369
A Deep Nonlinear Subspace Modeling and Reconstruction for Diffusion‐Weighted Imaging Using Denoising Auto‐Encoder
Purpose: To present a novel, nonlinear subspace modeling and joint k–q‐space reconstruction technique for high‐resolution, multi‐band, multi‐shell diffusion‐weighted imaging (DWI). Methods: High b ‐value (> 1000 s/mm 2 ), high resolution DWI has the drawback of generally low signal‐to‐noise ratios (SNRs). We present an approach that leverages a denoising autoencoder (DAE) to learn a latent subspace from biophysically simulated diffusion‐weighted signals. The decoder of this network is then used in the forward operator of the image reconstruction process. The decoded latent images are scaled by the image, phase is added and processed as regular DWI images with the forward operator for multi‐shot, multicoil, multi‐slice, k–q‐undersampled acquisition schemes. The performance is investigated with a multi‐shell, multi‐direction imaging brain scan and compared to the results of the multiplexed sensitivity‐encoding (MUSE) reconstruction and locally low‐rank (LLR) regularized reconstruction. The results are further validated by a bias and precision analysis of reconstructed fiber directions. Results: Comparing the reconstructed data using the proposed method shows improved noise suppression compared to MUSE and more details than LLR‐reconstructed images. Specifically, in the higher b ‐value domain, the reconstruction results show improved detectability of small structures. This bias and precision analysis showed minimal bias introduction, but higher precision with the proposed method. Conclusion: Our method combines deep learning, latent signal modeling, joint k–q‐space reconstruction, and biophysical simulation for diffusion data and shows strong noise suppression and a high degree of detail in reconstructed diffusion‐weighted images.
- 4 August 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (5) , 2359-2369
Open AccessA Deep Nonlinear Subspace Modeling and Reconstruction for Diffusion‐Weighted Imaging Using Denoising Auto‐Encoder
Purpose: To present a novel, nonlinear subspace modeling and joint k–q‐space reconstruction technique for high‐resolution, multi‐band, multi‐shell diffusion‐weighted imaging (DWI). Methods: High b ‐value (> 1000 s/mm 2 ), high resolution DWI has the drawback of generally low signal‐to‐noise ratios (SNRs). We present an approach that leverages a denoising autoencoder (DAE) to learn a latent subspace from biophysically simulated diffusion‐weighted signals. The decoder of this network is then used in the forward operator of the image reconstruction process. The decoded latent images are scaled by the image, phase is added and processed as regular DWI images with the forward operator for multi‐shot, multicoil, multi‐slice, k–q‐undersampled acquisition schemes. The performance is investigated with a multi‐shell, multi‐direction imaging brain scan and compared to the results of the multiplexed sensitivity‐encoding (MUSE) reconstruction and locally low‐rank (LLR) regularized reconstruction. The results are further validated by a bias and precision analysis of reconstructed fiber directions. Results: Comparing the reconstructed data using the proposed method shows improved noise suppression compared to MUSE and more details than LLR‐reconstructed images. Specifically, in the higher b ‐value domain, the reconstruction results show improved detectability of small structures. This bias and precision analysis showed minimal bias introduction, but higher precision with the proposed method. Conclusion: Our method combines deep learning, latent signal modeling, joint k–q‐space reconstruction, and biophysical simulation for diffusion data and shows strong noise suppression and a high degree of detail in reconstructed diffusion‐weighted images.
- Open Access
- 22 January 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (5) , 2852-2862
High‐Resolution Diffusion‐Weighted Imaging With Self‐Gated Self‐Supervised Unrolled Reconstruction
Purpose: High‐resolution diffusion‐weighted imaging (DWI) is clinically demanding. The purpose of this work is to develop an efficient self‐supervised algorithm unrolling technique for submillimeter‐resolution DWI. Methods: We developed submillimeter DWI acquisition utilizing multi‐band multi‐shot EPI with diffusion shift encoding. We unrolled the alternating direction method of multipliers (ADMM) to perform scan‐specific self‐gated self‐supervised DeepDWI learning for multi‐shot echo planar imaging with diffusion shift encoding on a clinical 7 T scanner. Results: We demonstrate that (1) ADMM unrolling is generalizable across slices, (2) ADMM unrolling outperforms multiplexed sensitivity‐encoding (MUSE) and compressed sensing with locally‐low rank (LLR) regularization in terms of image sharpness, tissue continuity, and motion robustness, and (3) ADMM unrolling enables clinically feasible inference time. Conclusion: Our proposed ADMM unrolling enables whole brain DWI of 21 diffusion volumes at 0.7 mm isotropic resolution and 10 min scan, and shows higher signal‐to‐noise ratio (SNR), clearer tissue delineation, and improved motion robustness, which makes it plausible for clinical translation.
- 22 January 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (5) , 2852-2862
Open AccessHigh‐Resolution Diffusion‐Weighted Imaging With Self‐Gated Self‐Supervised Unrolled Reconstruction
Purpose: High‐resolution diffusion‐weighted imaging (DWI) is clinically demanding. The purpose of this work is to develop an efficient self‐supervised algorithm unrolling technique for submillimeter‐resolution DWI. Methods: We developed submillimeter DWI acquisition utilizing multi‐band multi‐shot EPI with diffusion shift encoding. We unrolled the alternating direction method of multipliers (ADMM) to perform scan‐specific self‐gated self‐supervised DeepDWI learning for multi‐shot echo planar imaging with diffusion shift encoding on a clinical 7 T scanner. Results: We demonstrate that (1) ADMM unrolling is generalizable across slices, (2) ADMM unrolling outperforms multiplexed sensitivity‐encoding (MUSE) and compressed sensing with locally‐low rank (LLR) regularization in terms of image sharpness, tissue continuity, and motion robustness, and (3) ADMM unrolling enables clinically feasible inference time. Conclusion: Our proposed ADMM unrolling enables whole brain DWI of 21 diffusion volumes at 0.7 mm isotropic resolution and 10 min scan, and shows higher signal‐to‐noise ratio (SNR), clearer tissue delineation, and improved motion robustness, which makes it plausible for clinical translation.