Michal Touš
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Michal Touš has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- David Horňák
Institute of Process Engineering, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2, 616 69 Brno, Czech Republic
1 shared publication - Jiří Buzík
HUTIRA s.r.o., Vintrovna 398/29, 664 41 Popůvky u Brna, Czech Republic
1 shared publication - Marek Vondra
Institute of Process Engineering, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2, 616 69 Brno, Czech Republic
1 shared publication - Michaela Procházková
Institute of Process Engineering, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2, 616 69 Brno, Czech Republic
1 shared publication - Václav Miklas
Institute of Process Engineering, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2, 616 69 Brno, Czech Republic
1 shared publication - Vítězslav Máša
Brno University of Technology
1 shared publication
Latest Publications
- Open Access
Technology for Hot Spring Cooling and Geothermal Heat Utilization: A Case Study for Balneology Facility
Reducing energy costs in Europe is more challenging than before due to extreme price increases. The use of local renewable energy sources is one way to contribute to this effort. In the case of spa resorts, the use of heat from hot springs for therapeutic baths is an option. It is necessary to cool down this thermal mineral water to a temperature acceptable to the human body. However, due to the high mineral content of this water, heavy fouling can be a problem for conventional heat exchangers. The purpose of this study is to identify the suitable cooling technology in terms of required cooling capacity and waste heat recovery capability. The cooling technology was selected on the basis of a literature search. A pilot cooling unit consisting of vacuum cooler and plate heat exchanger was designed and tested in a real spa resort for six months. Both selected technologies have demonstrated the ability to cool thermal mineral water in long-term operation, as well as the possibility to utilize waste heat for domestic hot water heating. However, fouling problems occur in the plate heat exchanger. The vacuum cooler demonstrated greater operational robustness and resistance to encrustation.
Open AccessTechnology for Hot Spring Cooling and Geothermal Heat Utilization: A Case Study for Balneology Facility
Reducing energy costs in Europe is more challenging than before due to extreme price increases. The use of local renewable energy sources is one way to contribute to this effort. In the case of spa resorts, the use of heat from hot springs for therapeutic baths is an option. It is necessary to cool down this thermal mineral water to a temperature acceptable to the human body. However, due to the high mineral content of this water, heavy fouling can be a problem for conventional heat exchangers. The purpose of this study is to identify the suitable cooling technology in terms of required cooling capacity and waste heat recovery capability. The cooling technology was selected on the basis of a literature search. A pilot cooling unit consisting of vacuum cooler and plate heat exchanger was designed and tested in a real spa resort for six months. Both selected technologies have demonstrated the ability to cool thermal mineral water in long-term operation, as well as the possibility to utilize waste heat for domestic hot water heating. However, fouling problems occur in the plate heat exchanger. The vacuum cooler demonstrated greater operational robustness and resistance to encrustation.