Shuang Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shuang Wu has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Honglei Chen
Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China
2 shared publications Qinghua Liang
Shanghai Institute of Technical Physics
2 shared publications- Ruijun Ding
Key Laboratory of Infrared Imaging Materials and Detectors, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai, China
2 shared publications
Latest Publications
- Open Access
- 23 March 2023
- Published by Springer Nature in Research Square
CDS With Adjustable Interval for Low Noise Hyperspectral Infrared Focal Plane Readout circuits
Low noise is a key requirement of Readout Integrated Circuit (ROIC) in hyperspectral application for its low radiation. The Correlated Double Sampling (CDS) technology is commonly used to suppress the effect of noise. In this paper, CDS is improved by adjusting the time interval between the clamp and sample hold (SH), which can filter low frequency noise flexibly. A ROIC input stage integrated with low-noise Capacitive trans-impedance amplifiers (CTIA) and CDS with adjustable interval (AICDS) is designed. The SPECTRE simulation indicates that, by extending the CDS reset time, the simulation result is consistent with the analysis. The number of noise electrons reaches 32.59 e-, which is better than 56.7 e- without extending the reset time. The design of AICDS can improve the noise performance of hyperspectral ROIC, and can be widely used.
- 23 March 2023
- Published by Springer Nature in Research Square
Open AccessCDS With Adjustable Interval for Low Noise Hyperspectral Infrared Focal Plane Readout circuits
Low noise is a key requirement of Readout Integrated Circuit (ROIC) in hyperspectral application for its low radiation. The Correlated Double Sampling (CDS) technology is commonly used to suppress the effect of noise. In this paper, CDS is improved by adjusting the time interval between the clamp and sample hold (SH), which can filter low frequency noise flexibly. A ROIC input stage integrated with low-noise Capacitive trans-impedance amplifiers (CTIA) and CDS with adjustable interval (AICDS) is designed. The SPECTRE simulation indicates that, by extending the CDS reset time, the simulation result is consistent with the analysis. The number of noise electrons reaches 32.59 e-, which is better than 56.7 e- without extending the reset time. The design of AICDS can improve the noise performance of hyperspectral ROIC, and can be widely used.
- Open Access
- 12 December 2022
- Published by Springer Nature in Research Square
Reset Time Extended CDS for low noise hyperspectral infrared focal plane readout circuits
Low noise is a significant performance requirement of Hyperspectral Shortwave Infrared Focal Plane Arrays Readout Circuit (ROIC) for its low radiation. And the current Correlated Double Sampling (CDS) technology for noise reduction needs to be further improved. The mechanism of extended reset time CDS, which has an impact on noise, is analyzed; By establishing the "first-order low-pass filter, delay-subtractor, sample-hold" model, the output noise power spectral density of image pixel ROIC as a function of CDS extended reset time is analyzed. To verify the analysis, a pixel integrated with low-noise Capacitive trans-impedance amplifiers (CTIA) and adjustable reset time CDS is designed. By extending the CDS reset time, the simulation result is consistent with the analysis. The number of noise electrons reaches 24.42e-, which is better than 50.11e-without CDS and 34.45e-without extending the reset time. The design of Reset Time Extended CDS can improve the noise performance of hyperspectral readout circuits, and can be widely used.
- 12 December 2022
- Published by Springer Nature in Research Square
Open AccessReset Time Extended CDS for low noise hyperspectral infrared focal plane readout circuits
Low noise is a significant performance requirement of Hyperspectral Shortwave Infrared Focal Plane Arrays Readout Circuit (ROIC) for its low radiation. And the current Correlated Double Sampling (CDS) technology for noise reduction needs to be further improved. The mechanism of extended reset time CDS, which has an impact on noise, is analyzed; By establishing the "first-order low-pass filter, delay-subtractor, sample-hold" model, the output noise power spectral density of image pixel ROIC as a function of CDS extended reset time is analyzed. To verify the analysis, a pixel integrated with low-noise Capacitive trans-impedance amplifiers (CTIA) and adjustable reset time CDS is designed. By extending the CDS reset time, the simulation result is consistent with the analysis. The number of noise electrons reaches 24.42e-, which is better than 50.11e-without CDS and 34.45e-without extending the reset time. The design of Reset Time Extended CDS can improve the noise performance of hyperspectral readout circuits, and can be widely used.