Ruslan Fedyakin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ruslan Fedyakin has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Fares Abu-Abed
Department of Electronic Computers, Faculty of lnformation Technologies, Tver State Technical University, 22 Afanasiya Nikitina Emb., 170026 Tver, Russia
2 shared publications - Olga Zhironkina
Department of Foreign Languages, Kemerovo State University, 6 Krasnaya st., 650000 Kemerovo, Russia
2 shared publications - Sergey Zhironkin
Department of Trade and Marketing, Siberian Federal University, 79 Svobodny Av., 660041 Krasnoyarsk, Russia
2 shared publications - Yuri Matveev
Department of Electronic Computers, Faculty of lnformation Technologies, Tver State Technical University, 22 Afanasiya Nikitina Emb., 170026 Tver, Russia
2 shared publications
Latest Publications
- Open Access
Development of a Mobile Application for Visualizing the Hazard Zone During a Fire at an Industrial Enterprise Based on Cellular Automata
Accurate simulation modeling of the danger zone and real-time visualization of the toxic cloud spread during a fire and explosion at an industrial facility in a nearby urban area are in demand by rescue services conducting evacuation. Using a cellular automaton method allows us to create an optimal predictive model of the danger zone spread, combine modeling accuracy with computational speed, and consider multiple input variables and the cascading nature of an accident during visualization. The objective of this study was to develop a mobile application for calculating the parameters of the danger zone during an accident at an industrial facility caused by a toxic cloud spreading into an urban area, based on the selection of a cellular automaton algorithm. The primary objective of the study was a highly detailed visualization of the danger zone with several predicted values of toxic substance concentrations in the air. The authors developed a cellular automaton-based model, which forms the basis of the mobile application. It takes into account several variables characterizing chemicals in the explosion and fire zone, climate factors, occupancy, building parameters, and the availability of respiratory protection. The FireSoft Mobile app was developed using the Visual Studio 2022 development environment, C# 10.0, and .NET MAUI, adapted for Android 8.0 and higher. The mobile app was tested to visualize a cloud of toxic pollutants forming a hazardous zone in an urban agglomeration for cases involving an ammonia tank explosion and a large fire involving a large amount of polyvinyl chloride. The results demonstrate the app’s feasibility and effectiveness in predicting, planning, and managing evacuation measures during accidents at an industrial facility.
Open AccessDevelopment of a Mobile Application for Visualizing the Hazard Zone During a Fire at an Industrial Enterprise Based on Cellular Automata
Accurate simulation modeling of the danger zone and real-time visualization of the toxic cloud spread during a fire and explosion at an industrial facility in a nearby urban area are in demand by rescue services conducting evacuation. Using a cellular automaton method allows us to create an optimal predictive model of the danger zone spread, combine modeling accuracy with computational speed, and consider multiple input variables and the cascading nature of an accident during visualization. The objective of this study was to develop a mobile application for calculating the parameters of the danger zone during an accident at an industrial facility caused by a toxic cloud spreading into an urban area, based on the selection of a cellular automaton algorithm. The primary objective of the study was a highly detailed visualization of the danger zone with several predicted values of toxic substance concentrations in the air. The authors developed a cellular automaton-based model, which forms the basis of the mobile application. It takes into account several variables characterizing chemicals in the explosion and fire zone, climate factors, occupancy, building parameters, and the availability of respiratory protection. The FireSoft Mobile app was developed using the Visual Studio 2022 development environment, C# 10.0, and .NET MAUI, adapted for Android 8.0 and higher. The mobile app was tested to visualize a cloud of toxic pollutants forming a hazardous zone in an urban agglomeration for cases involving an ammonia tank explosion and a large fire involving a large amount of polyvinyl chloride. The results demonstrate the app’s feasibility and effectiveness in predicting, planning, and managing evacuation measures during accidents at an industrial facility.
- Open Access
Software for Hazard Zone Visualization in Case of Fire at Industrial Facility Based on Cellular Automaton Method
Modeling and visualizing zones within the spread of toxic clouds from fires and explosions during accidents at industrial facilities located near residential areas is of high practical value. This tool is critical for the rapid planning of population evacuation measures and emergency response. Of particular importance is the development of computer software that can quickly model the hazard zone of toxic cloud spread and superimpose it on a terrain map to determine the potential impact on residential areas. This software should be based on a mathematical model that can accurately predict the parameters of the hazard zone both near the industrial facility and beyond it, at a distance of more than 1 km. The objective of this study is to create algorithms for modeling the hazard zone during a fire or explosion at an industrial facility using a cellular automaton method and to develop a software tool for its visualization. The software must display the hazard zone for the population of a nearby residential area on a map in real time, which is necessary for assessing potential harm to residents’ health and in planning their rapid evacuation. To achieve this objective, this article presents a model for determining the boundaries and main parameters of a hazard zone based on the cellular automaton method (frontal and probabilistic). The proposed model takes into account both constants (properties of chemical substances, building parameters, population size, etc.) and variables (the mass of the substance at each explosion and fire, wind speed and direction, air temperature, etc.). The FireSoft III software, developed by the authors and based on the cellular automaton model, provides more rapid calculation of the parameters and delineation of the hazard zone boundaries compared to similar software, which was tested in cases of an ammonia tank explosion and a prolonged fire in a warehouse containing polyvinyl chloride at an enterprise. This makes FireSoft III promising for use in a fire and explosion response at enterprises.
Open AccessSoftware for Hazard Zone Visualization in Case of Fire at Industrial Facility Based on Cellular Automaton Method
Modeling and visualizing zones within the spread of toxic clouds from fires and explosions during accidents at industrial facilities located near residential areas is of high practical value. This tool is critical for the rapid planning of population evacuation measures and emergency response. Of particular importance is the development of computer software that can quickly model the hazard zone of toxic cloud spread and superimpose it on a terrain map to determine the potential impact on residential areas. This software should be based on a mathematical model that can accurately predict the parameters of the hazard zone both near the industrial facility and beyond it, at a distance of more than 1 km. The objective of this study is to create algorithms for modeling the hazard zone during a fire or explosion at an industrial facility using a cellular automaton method and to develop a software tool for its visualization. The software must display the hazard zone for the population of a nearby residential area on a map in real time, which is necessary for assessing potential harm to residents’ health and in planning their rapid evacuation. To achieve this objective, this article presents a model for determining the boundaries and main parameters of a hazard zone based on the cellular automaton method (frontal and probabilistic). The proposed model takes into account both constants (properties of chemical substances, building parameters, population size, etc.) and variables (the mass of the substance at each explosion and fire, wind speed and direction, air temperature, etc.). The FireSoft III software, developed by the authors and based on the cellular automaton model, provides more rapid calculation of the parameters and delineation of the hazard zone boundaries compared to similar software, which was tested in cases of an ammonia tank explosion and a prolonged fire in a warehouse containing polyvinyl chloride at an enterprise. This makes FireSoft III promising for use in a fire and explosion response at enterprises.