Foisal B. T. Siddiki
Research Subjects
Foisal B. T. Siddiki has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Maciej Krychowiak
Max Planck Institute for Plasma Physics, 17491 Greifswald, Germany
3 shared publications - Adrian von Stechow
Max Planck Institute for Plasma Physics
2 shared publications - Alexander Knieps
Forschungszentrum Jülich GmbH, Institute of Fusion Energy and Nuclear Waste Management—Plasma Physics, Partner of the Trilateral Euregio Cluster (TEC), 52425 Jülich, Germany
2 shared publications - Carsten Killer
Max Planck Institute for Plasma Physics, Wendelsteinstr. 1, 17491 Greifswald, Germany
2 shared publications - Dorothea Gradic
Max-Planck-Institut für Plasmaphysik, 17491 Greifswald, Germany
2 shared publications Jens P Knauer
2 shared publications
Latest Publications
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Measurement of radial electron density and temperature profile in the Wendelstein 7-X scrape off layer using the new outboard midplane thermal helium beam diagnostic
A new helium beam diagnostic has been implemented at the outboard midplane of the stellarator Wendelstein 7-X (W7-X) to measure edge plasma parameters in the scrape-off layer (SOL). The system provides localized measurements of electron density (ne) and temperature (Te) through spectroscopic observation of atomic helium emission lines combined with a collisional radiative model (CRM) with a radial spatial resolution of 4.5 mm. A gaseous beam of neutral helium atoms is injected radially into the plasma, and the resulting line emission is collected using a Schmidt Czerny Turner spectrometer. In this work, we discuss the successful implementation of the diagnostic, including the optical setup, data acquisition, and the analysis approach to obtain the ne(R, t) and Te(R, t) profiles using an advanced CRM. The diagnostic is benchmarked against a colocated alkali beam diagnostic and compared with other edge diagnostics, including the Multipurpose Manipulator, divertor Langmuir probes, and the divertor helium beam. These comparisons show that the midplane helium beam measurements are consistent with the expected edge plasma parameter range. A magnetic field line mapping methodology has also been established to enable cross-diagnostic comparisons in the three-dimensional island SOL geometry of W7-X. First, measurements from recent experimental campaigns demonstrate that the diagnostic can resolve radial ne and Te profiles in the main SOL region, providing a new capability for characterizing edge transport in W7-X.
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
Measurement of radial electron density and temperature profile in the Wendelstein 7-X scrape off layer using the new outboard midplane thermal helium beam diagnostic
A new helium beam diagnostic has been implemented at the outboard midplane of the stellarator Wendelstein 7-X (W7-X) to measure edge plasma parameters in the scrape-off layer (SOL). The system provides localized measurements of electron density (ne) and temperature (Te) through spectroscopic observation of atomic helium emission lines combined with a collisional radiative model (CRM) with a radial spatial resolution of 4.5 mm. A gaseous beam of neutral helium atoms is injected radially into the plasma, and the resulting line emission is collected using a Schmidt Czerny Turner spectrometer. In this work, we discuss the successful implementation of the diagnostic, including the optical setup, data acquisition, and the analysis approach to obtain the ne(R, t) and Te(R, t) profiles using an advanced CRM. The diagnostic is benchmarked against a colocated alkali beam diagnostic and compared with other edge diagnostics, including the Multipurpose Manipulator, divertor Langmuir probes, and the divertor helium beam. These comparisons show that the midplane helium beam measurements are consistent with the expected edge plasma parameter range. A magnetic field line mapping methodology has also been established to enable cross-diagnostic comparisons in the three-dimensional island SOL geometry of W7-X. First, measurements from recent experimental campaigns demonstrate that the diagnostic can resolve radial ne and Te profiles in the main SOL region, providing a new capability for characterizing edge transport in W7-X.
- Open Access
- 8 April 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (5)
Routes to high-performance operation in Wendelstein 7-X: turbulence suppression with shaping of the density profile.
Steep density gradients generally lead to improved plasma performance in the neoclassically optimized stellarator W7-X. This is evident in the global energy confinement time as well as in the ion temperature and can be explained by a strong reduction of the ion temperature gradient turbulence. Such conditions can experimentally be realized by several methods: injection of cryogenic hydrogen pellets, appropriate combination of neutral beam and electron cyclotron resonance heating and, in some cases, with low power of electron cyclotron resonance heating after preconditioning of the first wall. The duration of the improved phases is determined by the ability to sustain the steep density gradient, by technical limitations of the involved systems and, eventually, by the plasma stability. This paper gives an overview of relevant experimental results and presents example discharges where the improved confinement conditions could be extended to multiple seconds: up to 4 s using neutral beam injection and from 14 to 40 s with steady state pellet injection. In these plasmas the turbulent thermal diffusivity is reduced by a factor of 3 to 4 in a broad radial range, which allows high ion temperatures of up to 3 keV at the densities of about 1.5 • 10 20 m -3 .
- 8 April 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (5)
Open AccessRoutes to high-performance operation in Wendelstein 7-X: turbulence suppression with shaping of the density profile.
Steep density gradients generally lead to improved plasma performance in the neoclassically optimized stellarator W7-X. This is evident in the global energy confinement time as well as in the ion temperature and can be explained by a strong reduction of the ion temperature gradient turbulence. Such conditions can experimentally be realized by several methods: injection of cryogenic hydrogen pellets, appropriate combination of neutral beam and electron cyclotron resonance heating and, in some cases, with low power of electron cyclotron resonance heating after preconditioning of the first wall. The duration of the improved phases is determined by the ability to sustain the steep density gradient, by technical limitations of the involved systems and, eventually, by the plasma stability. This paper gives an overview of relevant experimental results and presents example discharges where the improved confinement conditions could be extended to multiple seconds: up to 4 s using neutral beam injection and from 14 to 40 s with steady state pellet injection. In these plasmas the turbulent thermal diffusivity is reduced by a factor of 3 to 4 in a broad radial range, which allows high ion temperatures of up to 3 keV at the densities of about 1.5 • 10 20 m -3 .
- Open Access
- 1 March 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (3) , 035029
First field test of a novel optical gas analyser in the exhaust of Wendelstein 7-X
A novel optical gas analyser, designed for isotope-resolved exhaust composition measurement, was field-tested at Wendelstein 7-X (W7-X) to validate its laboratory-proven concept under operational fusion experiment conditions. The system, Optix, comprises a cold cathode remote plasma generator and a high-resolution Fabry–Perot spectrometer and was deployed in the exhaust line of W7-X during the OP2.3 campaign. The injection of 3 He and 4 He for minority ion-cyclotron heating provided a test case for helium isotope discrimination. Despite limitations due to background gas and low partial pressures of the target species, isotope-resolved spectral signatures were successfully observed, demonstrating the fundamental viability of the Optix approach. Additionally, the spectrometer was evaluated for plasma emission measurements from both core and edge sightlines. While helium line emission was detectable, interpretation was hindered by complex background signals, highlighting the benefits of controlled remote plasma generators for spectroscopy. This first deployment provides critical insight into pressure requirements, spectral resolution, and operational constraints, informing future applications of optical exhaust diagnostics in fusion devices.
- 1 March 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (3) , 035029
Open AccessFirst field test of a novel optical gas analyser in the exhaust of Wendelstein 7-X
A novel optical gas analyser, designed for isotope-resolved exhaust composition measurement, was field-tested at Wendelstein 7-X (W7-X) to validate its laboratory-proven concept under operational fusion experiment conditions. The system, Optix, comprises a cold cathode remote plasma generator and a high-resolution Fabry–Perot spectrometer and was deployed in the exhaust line of W7-X during the OP2.3 campaign. The injection of 3 He and 4 He for minority ion-cyclotron heating provided a test case for helium isotope discrimination. Despite limitations due to background gas and low partial pressures of the target species, isotope-resolved spectral signatures were successfully observed, demonstrating the fundamental viability of the Optix approach. Additionally, the spectrometer was evaluated for plasma emission measurements from both core and edge sightlines. While helium line emission was detectable, interpretation was hindered by complex background signals, highlighting the benefits of controlled remote plasma generators for spectroscopy. This first deployment provides critical insight into pressure requirements, spectral resolution, and operational constraints, informing future applications of optical exhaust diagnostics in fusion devices.
- Open Access
- 13 January 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (2)
A fast helium beam diagnostic at the island divertor of W7-X for the investigation of plasma edge dynamics
Understanding and quantifying particle and energy transport at the plasma edge region is crucial for magnetic confinement fusion. For this purpose, a new polychromator system with 1 µs time resolution was installed for the thermal helium beam diagnostic in the island divertor of the stellarator W7-X. The time resolution is four orders of magnitude faster than the spectrometer-based system. This allows for the first time access to turbulence-relevant time scales, enabling the investigation of plasma edge dynamics such as modes and instabilities. Their connection to averaged plasma profiles is likewise accessible with this diagnostic. Furthermore, the diagnostic system measures in two magnetically connected divertors, which enables the study of long-range correlation of fluctuations. Utilising a collisional-radiative model, the diagnostic can reconstruct fast electron density and temperature variations with an effective resolution of 10 kHz, associated with plasma modes and bursts. Additionally, it provides high temporal resolution measurements of the detachment process in the divertor. Since it simultaneously measures at an upper and lower divertor, it is the first edge diagnostic at W7-X capable of measuring the up-down asymmetry of turbulence. This article presents the design and implementation of the diagnostic as well as an analysis of the signal quality. It also looks at the influence of diagnostic gas puffs on the plasma in detail. To present the potential of the diagnostic, this work briefly shows a long-range correlation analysis of an edge mode between two divertors that are magnetically connected as well as the electron temperature and density calculation for this mode. Furthermore, a detachment process measured with high time resolution is presented.
- 13 January 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (2)
Open AccessA fast helium beam diagnostic at the island divertor of W7-X for the investigation of plasma edge dynamics
Understanding and quantifying particle and energy transport at the plasma edge region is crucial for magnetic confinement fusion. For this purpose, a new polychromator system with 1 µs time resolution was installed for the thermal helium beam diagnostic in the island divertor of the stellarator W7-X. The time resolution is four orders of magnitude faster than the spectrometer-based system. This allows for the first time access to turbulence-relevant time scales, enabling the investigation of plasma edge dynamics such as modes and instabilities. Their connection to averaged plasma profiles is likewise accessible with this diagnostic. Furthermore, the diagnostic system measures in two magnetically connected divertors, which enables the study of long-range correlation of fluctuations. Utilising a collisional-radiative model, the diagnostic can reconstruct fast electron density and temperature variations with an effective resolution of 10 kHz, associated with plasma modes and bursts. Additionally, it provides high temporal resolution measurements of the detachment process in the divertor. Since it simultaneously measures at an upper and lower divertor, it is the first edge diagnostic at W7-X capable of measuring the up-down asymmetry of turbulence. This article presents the design and implementation of the diagnostic as well as an analysis of the signal quality. It also looks at the influence of diagnostic gas puffs on the plasma in detail. To present the potential of the diagnostic, this work briefly shows a long-range correlation analysis of an edge mode between two divertors that are magnetically connected as well as the electron temperature and density calculation for this mode. Furthermore, a detachment process measured with high time resolution is presented.